Schneider Electric

IEC Magnetic Contactor, 3 Poles, 24 V AC, 50 A, Reversing: No


product price: $295.99
/ea
Free Shipping & Returns

Free Shipping on orders over $50
Free 30-Day Returns

Key Features

  • Full Load Amps-Inductive 50 A
  • Full Load Amps-Resistive 80 A
  • Action Non-Reversing
  • Number of Poles 3
  • Reversing No
See all product information

Product Information

Dimensions

Height 2.17 in
Width 2.17 in
Depth 4.61 in
Working Height Up to 9842.52 ft
Overall Height 4.8 in
Overall Depth 4.72 in
Overall Width 2.17 in

Details

Item IEC Magnetic Contactor
Full Load Amps-Inductive 50 A
Full Load Amps-Resistive 80 A
Action Non-Reversing
Number of Poles 3
Coil Volts 24 V AC
Reversing No
HP @ 1 Phase - 230V 7-1/2
HP @ 1 Phase - 120V 3 hp
HP @ 1 Phase - 240V 7 1/2 hp
HP @ 3 Phase - 208V 15 hp
HP @ 3 Phase - 240V 15 hp
HP @ 3 Phase - 575V 40 hp
Enclosure NEMA Rating No Enclosure
HP @ 3 Phase - 480V 40 hp
Aux. Contact Configuration 1NO/1NC
Hz 50/60
Auxiliary Contact Form 1NO/1NC
Frame / Series / Class / Code TeSys
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Includes Everlink Power Connections
Series TeSys Deca
Rated Insulation Volts 600/690V
Electrical Durability 1.45 Mcycles (50 A, AC-3, Less than 440 V); 1.1 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
IP Rating IP20
Impulse Withstand Voltage 6 kV
Switching Voltage 17 V (Signalling Circuit)
Inrush VA 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Rated Voltage 690V AC, 300V DC
Features Without Built-In Suppressor Module
Thermal Amperage 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Operating Time 4 to 19 ms (Opening), 12 to 26 ms (Closing)
Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Operating Speed 3600 cycles per hr
Shock Resistance 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Impedance 1.5 mOhm
Max. Operating Watts 15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Signalling Circuit Frequency 25 to 400 Hz
Electrical Connection Screw Clamp Terminals
Application Motor Control, Resistive Load
Max. Temperature 850°C
Non-Overlap Time 1.5 ms
Mounts On Plate, Rail
Hold VA 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Watts Loss 4 to 5W
Fuse Amps 10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Mechanical Durability 6 Mcycles
Includes Protective Cover Yes
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Net Weight 0.855 kg
Switching Current 5 mA (Signalling Circuit)
Tightening Torque 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Fire Rating UL 94 V1
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Overvoltage Category CAT III
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Rated Breaking Capacity 900 A @ 440V
Rated Short-Time Withstand Current 400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Coil Voltage 24V AC
Horsepower @ Single Phase - 240V AC 7 1/2 hp
Maximum Operating Temperature 140 Degrees F
Horsepower @ Three Phase - 480V AC 40 hp
Horsepower @ Three Phase - 208V AC 15 hp
Reversing Capability Non-Reversing
Contactor Style IEC
Electrical Operating Durability 1,100,000, 1,450,000
Horsepower @ Single Phase - 120V AC 3 hp
Full Load Current - Resistive 80 A
Maximum Voltage Rating 690V AC
Full Load Current - Inductive 50 A
Number of Normally Open Main Contacts 3
Mounting Style DIN Rail, Plate
NEMA Enclosure Rating No Enclosure
Frequency 50/60 Hz
Number of Auxillary Contacts 2
Resistance Properties Fire Resistant, Insulation Resistant
Phase Three
Horsepower @ Three Phase - 600V AC 40 hp
Embedded Surge Suppressor No
Minimum Operating Temperature -40 Degrees F
Includes Auxiliary Contacts Yes
Horsepower @ Three Phase - 240V AC 15 hp
Terminal Connection Type Screw Clamp Terminals
Mechanical Operating Durability 6,000,000
Protective Cover With
Compatibility Code LC1D
Contact Compatibility M2
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Maximum Horse Power Rating 3 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Rated Impulse Withstand Voltage 6 kV IEC 60947
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Motor Power KW 15 kW at 220 to 230 V AC 50/60 Hz (AC-3); 22 kW at 380 to 400 V AC 50/60 Hz (AC-3); 30 kW at 500 V AC 50/60 Hz (AC-3); 33 kW at 660 to 690 V AC 50/60 Hz (AC-3); 25 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 11 kW at 400 V AC 50/60 Hz (AC-4); 15 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 22 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 30 kW at 500 V AC 50/60 Hz (AC-3e); 33 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 25 kW at 415 V AC 50/60 Hz (AC-3e); 30 kW at 440 V AC 50/60 Hz (AC-3e)
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Pollution Degree 3
Product Certifications DNV; LROS (Lloyds register of shipping); CCC; GOST; BV; RINA; CSA; UL; GL
Pole Contact Composition 3 NO
Contactor Application Resistive load; Motor control
Rated Operational Current 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Connections - Terminals Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw connection 1 0.00 to 0.05 in² (1 to 35 mm²) - cable stiffness: flexible without cable end; Power circuit: screw connection 2 0.00 to 0.04 in² (1 to 25 mm²) - cable stiffness: flexible without cable end; Power circuit: screw connection 1 0.00 to 0.05 in² (1 to 35 mm²) - cable stiffness: flexible with cable end; Power circuit: screw connection 2 0.00 to 0.04 in² (1 to 25 mm²) - cable stiffness: flexible with cable end; Power circuit: screw connection 1 0.00 to 0.05 in² (1 to 35 mm²) - cable stiffness: solid without cable end; Power circuit: screw connection 2 0.00 to 0.04 in² (1 to 25 mm²) - cable stiffness: solid without cable end
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Poles Description 3P
Inrush Power in VA 140 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 160 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Conventional Free Air Thermal Current 10 A (at 140°F (60°C)) for signalling circuit; 80 A (at 140°F (60°C)) for power circuit
IRMS Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Type AC 50/60 Hz standard
Maximum Operating Rate 3600 cyc/h 140°F (60°C)
Flame Retardance V1 conforming to UL 94
Product Or Component Type Contactor
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
Mounting Support Plate; Rail
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 10 Gn for 11 ms)
Control Circuit Voltage 24 V AC 50/60 Hz
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1; 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Minimum Switching Current 5 mA for signalling circuit
Heat Dissipation 4 to 5 W at 50/60 Hz
Rated Insulation Voltage Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL; Power circuit 690 V IEC 60947-4-1
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Auxiliary Contact Composition 1 NO + 1 NC
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption in VA 13 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Power Dissipation Per Pole 3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e
Minimum Switching Voltage 17 V for signalling circuit
Protective Treatment THIEC 60068-2-30
Rated Short Time Withstand Current 400 A 104°F (40°C) - 10 s for power circuit; 810 A 104°F (40°C) - 1 s for power circuit; 84 A 104°F (40°C) - 10 min for power circuit; 208 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
IP Degree Of Protection IP20 front face IEC 60529
Permissible Ambient Air Temperature Around The Device -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Utilisation Category AC-4; AC-1; AC-3; AC-3e
Insulation Resistance Greater than 10 MOhm for signalling circuit

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.