Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
7-1/2
HP @ 3 Phase - 575V
40 hp
Includes
Everlink Power Connections
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Application
Motor Control, Resistive Load
Impulse Withstand Voltage
6 kV
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Rated Short-Time Withstand Current
400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Includes Protective Cover
Yes
Operating Speed
3600 cycles per hr
Electrical Durability
1.45 Mcycles (50 A, AC-3, Less than 440 V); 0.5 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
Fuse Amps
10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Mechanical Durability
10 Mcycles
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Overvoltage Category
CAT III
Switching Current
5 mA (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity
900 A @ 440V
Switching Voltage
17 V (Signalling Circuit)
Rated Insulation Volts
600/690V
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Max. Operating Watts
15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Operating Time
42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening)
Signalling Circuit Frequency
25 to 400 Hz
Control Circuit Voltage Limits
Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C); Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Maximum Operating Temperature
140 Degrees F
Full Load Current - Inductive
50 A
Horsepower @ Three Phase - 480V AC
40 hp
Number of Normally Open Main Contacts
3
Mounting Style
DIN Rail, Plate
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 240V AC
15 hp
Horsepower @ Three Phase - 600V AC
40 hp
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Single Phase - 240V AC
7 1/2 hp
Embedded Surge Suppressor
Yes
Resistance Properties
Fire Resistant, Insulation Resistant
Mechanical Operating Durability
10,000,000
Horsepower @ Three Phase - 208V AC
15 hp
Includes Auxiliary Contacts
Yes
Maximum Voltage Rating
690V AC
Electrical Operating Durability
1,450,000, 500,000
Horsepower @ Single Phase - 120V AC
3 hp
Full Load Current - Resistive
80 A
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)