IEC Magnetic Contactor, No Auxiliary Contacts, 120V AC, 4 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D128G7

  • Zoro # G0478287


product price:  $186.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
No Auxiliary Contacts
Coil Voltage
120V AC
Number of Poles
4
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D128G7
Zoro #
G0478287
UPC #
785901407911
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
3.35 in
Overall Width
1.77 in
Overall Depth
3.62 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
No Auxiliary Contacts
Coil Voltage
120V AC
Number of Poles
4
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
Reversing
No
Frame / Series / Class / Code
TeSys
Series
TeSys Deca
Signalling Circuit Frequency
25 to 400 Hz
Impedance
2.5 mOhm
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Operating Speed
3600 cycles per hr
Features
Without Built-In Suppressor Module
Fire Rating
UL 94 V1
Inrush VA
70 VA
Electrical Durability
0.8 Mcycles (25 A, AC-1, Less than 440 V)
Rated Insulation Volts
600/690V
Watts Loss
2 to 3W
Includes Protective Cover
Yes
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Mechanical Durability
15 Mcycles
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Tightening Torque
1.7 Nm
Impulse Withstand Voltage
6 kV
Application
Resistive Load
Switching Voltage
17 V (Signalling Circuit)
Rated Short-Time Withstand Current
105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Net Weight
0.365 kg
IP Rating
IP20
Non-Overlap Time
1.5 ms
Rated Breaking Capacity
250 A @ 440V
Overvoltage Category
CAT III
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Fuse Amps
10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
Switching Current
5 mA (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Includes Auxiliary Contacts
Yes
Full Load Current - Inductive
12:00 AM
Maximum Operating Temperature
140 Degrees F
Number of Normally Closed Main Contacts
2
Mechanical Operating Durability
15,000,000
Number of Normally Open Main Contacts
2
Maximum Voltage Rating
690V AC
Electrical Operating Durability
800,000
NEMA Enclosure Rating
No Enclosure
Full Load Current - Resistive
25 A
Contactor Style
IEC
Mounting Style
DIN Rail, Plate
Embedded Surge Suppressor
No
Minimum Operating Temperature
-40 Degrees F
Frequency
50/60 Hz
Resistance Properties
Fire Resistant
Pollution Degree
3
Contact Compatibility
M6
Rated Operational Current
25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Power Dissipation Per Pole
1.56 W AC-1
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Protective Cover
With
Protective Treatment
THIEC 60068-2-30
Control Circuit Voltage
120 V AC 50/60 Hz
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)
Heat Dissipation
2 to 3 W at 50/60 Hz
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Conventional Free Air Thermal Current
25 A (at 140°F (60°C)) for power circuit; 10 A (at 140°F (60°C)) for signalling circuit
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Type
AC 50/60 Hz
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Utilisation Category
AC-1; AC-3; AC-3e; AC-4
Pole Contact Composition
2 NO + 2 NC
Compatibility Code
LC1D
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The Schneider Electric IEC Magnetic Contactor is a 4-pole, non-reversing, coil-operated switch rated for operation with resistive loads within specified parameters. It uses screw clamp terminals and is compatible with DIN Rail or Plate mounting. The unit is part of the TeSys Deca family and is intended to facilitate power circuit switching in accordance with applicable standards.

Coil voltage: 120 V AC

  • Poles/contacts: 4 poles; main contacts 2 NO + 2 NC; auxiliary contacts: No Auxiliary Contacts
  • Reversing: Non-Reversing
  • Mounting/terminals: DIN Rail, Plate; Screw Clamp terminals
  • Load/application: Resistive Load
  • Maximum voltage (power circuit): 690 V AC
  • Full-load currents: Rated for maximum continuous current of 25 A (resistive) and 12 A (inductive) under specified conditions
  • Frequency: 50/60 Hz
  • IP/ enclosure: IP20 front face; No Enclosure
  • Protective cover: Includes a protective cover as part of the product features
  • Dimensions/weight: Width 1.77 in; Height 3.35 in; Depth 3.62 in; Weight 0.365 kg
  • Standards: EN 60947-4-1; EN 60947-5-1; UL 508; UL Listed; CSA; IEC 60947-1
  • Series/frame: TeSys Deca
  • Other notable specs: Inrush 70 VA; Hold-in 7.5 VA (60 Hz) / 7 VA (50 Hz); Impedance 2.5 mΩ; Operating times 12–22 ms (closing), 4–19 ms (opening)
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.