Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC2K0901F7
Zoro #
G0878035
UPC #
785901883487
Country of Origin
France

Dimensions

Working Height
6561.68 ft
Overall Depth
2.24 in
Overall Height
2.28 in
Overall Width
3.54 in

Details

Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NC
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
1-1/2
Reversing
Yes
HP @ 3 Phase - 575V
5 hp
Frame / Series / Class / Code
TeSys
Series
TeSys K
Mechanical Durability
5 Mcycles
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Impulse Withstand Voltage
8 kV
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Signalling Circuit Frequency
Less Than 400 Hz
Application
Motor Control, Resistive Load
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
Features
Preassembled with Reversing Power Busbar
Inrush VA
30 VA
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Overvoltage Category
CAT III
Switching Voltage
17 V (Signalling Circuit)
Rated Making Capacity
110 A
Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
IP Rating
IP20
Watts Loss
1.3W
Rated Insulation Volts
600/690V
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Electrical Durability
0.18 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (9 A, AC-3, Less than 440 V); 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
Switching Current
5 mA (Signalling Circuit)
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Tightening Torque
0.8 to 1.3 Nm
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Net Weight
0.39 kg
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Impedance
3 mOhm
Hold VA
4.5 VA
Operating Speed
3600 cycles per hr
Horsepower @ Three Phase - 208V AC
2 hp
NEMA Enclosure Rating
No Enclosure
Mechanical Operating Durability
5,000,000
Horsepower @ Three Phase - 480V AC
5 hp
Frequency
50/60 Hz
Full Load Current - Inductive
9:00 AM
Embedded Surge Suppressor
No
Maximum Operating Temperature
122 Degrees F
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Number of Normally Open Main Contacts
3
Minimum Operating Temperature
-13 Degrees F
Includes Auxiliary Contacts
Yes
Maximum Voltage Rating
690V AC
Mounting Style
DIN Rail, Plate
Electrical Operating Durability
1,300,000, 180,000
Horsepower @ Three Phase - 600V AC
5 hp
Horsepower @ Three Phase - 240V AC
3 hp
Horsepower @ Single Phase - 120V AC
1/2 hp
Resistance Properties
Insulation Resistant
Full Load Current - Resistive
20 A
Contactor Style
IEC
Conventional Free Air Thermal Current
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)

Description

The Schneider Electric IEC Miniature Magnetic Contactor is a compact, electrically operated switch (TeSys K) rated for controlling circuits within specified power ranges in IEC-style control panels. It features reversing action and 3 poles, with 1NC auxiliary contact. The coil operates at 120 V AC and uses screw clamp terminals. It is intended for IEC applications and can be mounted on a DIN rail or plate with no enclosure included.

Action: Reversing

  • Poles: 3
  • Auxiliary Contacts: 1NC
  • Coil Voltage: 120 V AC
  • Mounting: DIN Rail, Plate
  • Electrical Connection: Screw Clamp Terminals
  • Series/Style: TeSys K; IEC
  • Maximum Voltage Rating: 690 V AC
  • IP Rating: IP20
  • Full Load Currents: 20 A (Resistive) / 9 A (Inductive)
  • Rated Making Capacity: 110 A
  • Dimensions (W × H × D): 3.54 in × 2.28 in × 2.24 in
  • Net Weight: 0.39 kg
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.