- Item
- Joystick Operator
- Number of Directions
- 2
- Contact Form
- 1NO
- Contact Rating
- 10A @ 600V AC
- Joystick Material
- Metal
- Action
- Momentary
- NEMA Rating
- 13, 4X
- Latching / Non-Latching
- Non-Latching
- Direction of Operation
- Vertical
- IP Rating
- IP66
- NEMA Contact Rating Designation
- R300
- Standards
- China RoHS, EU RoHS, REACH, WEEE
- Bezel
- Chromium Plated Metal
- Vibration Resistance
- 5 gn 2-500 Hz)IEC 60068-2-6
- Tightening Torque
- 0.8-1.2 N.m EN 60947-1
- Connections - Terminals
- screw clamp terminals, <= 2 x 1.5 mm² with cable end EN 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN 60947-1
- Ambient Air Temperature For Storage
- -40-70°C
- [Ie] Rated Operational Current
- 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 || 0.22 A 125 V, DC-13, R300 EN/IEC 60947-5-1
- Product Or Component Type
- joystick controller
- Operator Position Information
- 3 positions
- Protective Treatment
- TH
- Contacts Usage
- standard
- Notch Per Direction
- 1-1
- Electrical Shock Protection Class
- class I IEC 60536
- Operator Direction Information
- 2 directions
- Short-Circuit Protection
- 10 A cartridge fuse gG EN/IEC 60947-5-1
- Fixing Collar Material
- zamak
- Shock Resistance
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Positive Opening
- without
- Shape Of Screw Head
- cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
- Contact Operation
- slow-break
- Device Short Name
- XD4
- Electrical Durability
1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
- Electrical Reliability
- λ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
- Contacts Type And Composition
- 1 NO
- Mechanical Durability
- 1000000 cycles
- Ip Degree Of Protection
- IP66 IEC 60529
- [Ui] Rated Insulation Voltage
- 600 V 3)EN 60947-1
- [Ith] Conventional Free Air Thermal Current
- 10 A EN/IEC 60947-5-1
- Shape Of Signaling Unit Head
- round
- Resistance To High Pressure Washer
- 7000000 Pa 55°C 0.1 m
- Type Of Operator
- spring return to 0 position, long operating shaft 54 mm
- Ik Degree Of Protection
- IK03 IEC 50102
- Device Presentation
- complete product
- Product Certifications
- DNV || LROS (Lloyds register of shipping) || UL Listed || BV || GL || CSA
- Ambient Air Temperature For Operation
- -25-70°C
- Contacts Material
- silver alloy (Ag/Ni)
- Bezel Material
- Metal
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN 60947-1
- Nema Degree Of Protection
- NEMA 13 || NEMA 4X
- Conventional Free Air Thermal Current
- 10 A IEC 60947-5-1
- Rated Operational Current
- 0.1 A 250 V, DC-13, R300 IEC 60947-5-1; 0.22 A 125 V, DC-13, R300 IEC 60947-5-1
- Rated Insulation Voltage
- 600 V 3)IEC 60947-1
- Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- DC Contact Rating
- 0.1 A @ 250 V, 0.22 A @ 125 V
- Latch Type
- Non-Latching
- Series
- XB4
- Number of Positions
- 2
- Switch Action
- Momentary
- NEMA Enclosure Rating
- 13, 4X
- AC Contact Rating
- 1.5 A @ 240 V, 3 A @ 120 V