- Item
- Motor Starter Power Base
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 110V-240V AC/DC
- Number of Poles
- 3
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Standards
- CCC, CSA, EAC, Green Premium RoHS/REACH, UL Listed
- HP @ 3 Phase - 575V
- 10 hp
- Enclosure Type
- Open
- Features
- Mercury Free; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration; Suitability For Isolation
- HP @ 1 Phase - 230V
- 2 hp
- Operating Voltage
- 690V AC
- Weight
- 1.27 kg
- Starter Style
- IEC
- Compatible with Series
- TeSys Ultra
- Horsepower @ Three Phase - 240V AC
- 3 hp
- Horsepower @ Three Phase - 600V AC
- 10 hp
- Frequency
- 50/60 Hz
- Horsepower @ Three Phase - 208V AC
- 3 hp
- Horsepower @ Three Phase - 480V AC
- 7 1/2 hp
- Maximum Overload Relay Current Setting
- 12 A
- Horsepower @ Single Phase - 120V AC
- 1 1/2 hp
- NEMA Enclosure Rating
- No Enclosure
- Horsepower @ Single Phase - 240V AC
- 2 hp
- Maximum Voltage Rating
- 690V AC
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Fixing Mode
- Clipped DIN rail; Screw-fixed plate)
- Shock Resistance
- 10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
- Rated Service Breaking Capacity
- 50 kA 230 V; 50 kA 440 V; 10 kA 500 V; 4 kA 690 V
- Typical Current Consumption
- 1000 mA 110 to 220 V DC I maximum while closing; 1000 mA 110 to 240 V AC I maximum while closing
- Operating Time
- 150 ms with change of direction power circuit; 35 ms opening control circuit; 75 ms without change of direction power circuit; 50 ms closing control circuit
- Inrush Restraint Duration
- 25 ms AC 50/60 Hz; 15 ms DC
- Rated Insulation Voltage
- 690 V IEC 60947-6-2 3; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
- Control Circuit Voltage Limits
- 55 V DC drop-out; 55 V AC drop-out; 88 to 242 V DC in operation; 88 to 264 V AC in operation
- Resistance To Fast Transients
- 2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
- Resistance To Radiated Fields
- 9.14 V/m (10 V/m) 3 IEC 61000-4-3
- Operating Altitude
- 6561.68 ft (2000 m)
- Safe Separation Of Circuit
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
- Maximum Operating Rate
- 3600 cyc/h
- Fire Resistance
- 1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
- Compatibility Code
- LU2B
- Immunity To Radioelectric Fields
- 10 V IEC 61000-4-6
- Protective Treatment
- TH IEC 60068
- Utilisation Category
- AC-43; AC-44; AC-41
- Conventional Free Air Thermal Current
- 12 A
- Tightening Torque
Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) flat 0.20 in (5 mm); Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) Philips no 1 0.20 in (5 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) flat 0.24 in (6 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) Philips No 2 0.24 in (6 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) pozidriv No 2 0.24 in (6 mm)
- Auxiliary Contacts Type
- Linked contacts 1 NO + 1 NC) IEC 60947-4-1; Mirror contact 1 NC) IEC 60947-1
- Vibration Resistance
- 2 gn 5 to 300 Hz) power poles open IEC 60068-2-27; 4 gn 5 to 300 Hz) power poles closed IEC 60068-2-27
- Control Circuit Voltage
- 110 to 240 V AC 50/60 Hz; 110 to 220 V DC
- Immunity To Voltage Dips
- 70% / 500 ms IEC 61000-4-11
- Suitability For Isolation
- Yes
- IP Degree Of Protection
- IP20 IEC 60947-1 front panel and wired terminals); IP20 IEC 60947-1 other faces); IP40 IEC 60947-1 front panel outside connection zone)
- Resistance To Electrostatic Discharge
- 8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
- Immunity To Microbreaks
- 3 ms control circuit
- Connections - Terminals
Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²) flexible with cable end; Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.75 to 1.5 mm²) flexible without cable end; Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.75 to 1.5 mm²) rigid; Control circuit screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²) flexible with cable end; Control circuit screw clamp terminals 2 0.00 to 0.00 in² (0.75 to 1.5 mm²) flexible without cable end; Control circuit screw clamp terminals 2 0.00 to 0.00 in² (0.75 to 1.5 mm²) rigid; Power circuit screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) rigid; Power circuit screw clamp terminals 1 0.00 to 0.01 in² (1 to 6 mm²) flexible with cable end; Power circuit screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) flexible without cable end; Power circuit screw clamp terminals 2 0.00 to 0.01 in² (1 to 6 mm²) flexible with cable end; Power circuit screw clamp terminals 2 0.00 to 0.01 in² (1 to 6 mm²) rigid; Power circuit screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) flexible without cable end
- Ambient Air Temperature For Storage
- -40 to 185°F (-40 to 85°C)
- Mechanical Durability
- 15 Mcycles
- Non-Dissipating Shock Wave
- 1 kV serial mode IEC 60947-6-2; 2 kV common mode IEC 60947-6-2
- Heat Dissipation
- 2 W control circuit with LUCA, LUCB, LUCC, LUCD; 1.7 W control circuit with LUCM
- Rated Operational Current
- 12 A Less than or Equal to 440 V; 12 A 500 V; 9 A 690 V
- Rated Impulse Withstand Voltage
- 6 kVIEC 60947-6-2
- Current AC
- 12:00 AM
- Minimum Operating Temperature
- -13 Degrees F
- Compatible Manufacturer Model Number
- LUC.X6FU; LUC.1XFU; LUC.05FU; LUC.12FU
- Maximum Operating Temperature
- 140 Degrees F