CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1
Coil Volts
110 to 240V AC; 110 to 220V DC
Number of Poles
3
Hz
40 to 60 Hz
Features
Protection against overload and short-circuit; Manual reset; Earth fault protection; Protection against phase failure and phase imbalance; Free of Halogen, Mercury & Pvc; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
Separate Mounting
No
Trip Class - Overload
10
Kit Required for Retrofit Mtg.
No
Sensing Method
Thermal
Frame / Series / Class / Code
Class 10
Use With - Contactors and Starters
Mfr. Series LUA1C Contactors
Weight
0.135 kg
Reset Type
Manual
Compatible with Series
TeSys Ultra
Minimum Operating Temperature
-13 Degrees F
Phase
Three
Maximum Operating Temperature
158 Degrees F
Maximum Rated Motor Current Adjustment
12 A
Minumum Rated Motor Current Adjustment
3 A
Compatible Manufacturer Model Number
LUB12, LUB32, LUB38
Motor Power KW
5.5 kW 400 to 440 V AC 50/60 Hz; 5.5 kW 500 V AC 50/60 Hz; 9 kW 690 V AC 50/60 Hz
Rated Insulation Voltage
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
Main Function Available
Protection against overload and short-circuit; Manual reset; Earth fault protection; Protection against phase failure and phase imbalance
Resistance To Radiated Fields
9.14 V/m (10 V/m) 3 IEC 61000-4-3
Immunity To Microbreaks
3 ms
Tripping Threshold
14.2 x Ir +/- 20%
Compatibility Code
LUCA
Ambient Air Temperature For Operation
-13 to 158°F (-25 to 70°C)
Product Compatibility
Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12FU; Reversing contactor breaker LU2B32FU; Reversing contactor breaker LU2B38FU
Phase Failure Sensitivity
Yes
Operating Altitude
6561.68 ft (2000 m)
Typical Current Consumption
280 mA 110 to 240 V AC I maximum while closing with LUB12; 280 mA 110 to 240 V AC I maximum while closing with LUB32; 280 mA 110 to 240 V AC I maximum while closing with LUB38; 280 mA 110 to 220 V DC I maximum while closing with LUB12; 280 mA 110 to 220 V DC I maximum while closing with LUB32; 280 mA 110 to 220 V DC I maximum while closing with LUB38; 35 mA 110 to 240 V AC I rms sealed with LUB12; 25 mA 110 to 240 V AC I rms sealed with LUB32; 25 mA 110 to 240 V AC I rms sealed with LUB38; 35 mA 110 to 220 V DC I rms sealed with LUB12; 25 mA 110 to 220 V DC I rms sealed with LUB32; 25 mA 110 to 220 V DC I rms sealed with LUB38
Control Circuit Voltage Limits
88 to 264 V AC 110 to 240 V in operation; 88 to 242 V DC 110 to 220 V in operation; 55 V AC 110 to 240 V drop-out; 55 V DC 110 to 220 V drop-out
Fixing Mode
Plug-in front face)
Operating Time
35 ms opening with LUB12 control circuit; 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 50 ms closing with LUB12 control circuit; 50 ms closing with LUB32 control circuit; 50 ms closing with LUB38 control circuit
Utilisation Category
AC-41; AC-43; AC-44
Protective Treatment
TH IEC 60068
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Load Type
3-phase motor self-cooled
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
Immunity To Voltage Dips
70% / 500 ms IEC 61000-4-11
Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Ambient Air Temperature For Storage
-40 to 185°F (-40 to 85°C)
Product Specific Application
Basic protection requirements for motor starters: overload and short-circuit
Rated Operational Voltage
690 V AC
Product Certifications
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
Fire Resistance
1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Shock Resistance
10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
Vibration Resistance
2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Heat Dissipation
2 W control circuit with LUB12; 3 W control circuit with LUB32; 3 W control circuit with LUB38
Thermal Overload Class
Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2; Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Product Or Component Type
Standard control unit
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
Non-Dissipating Shock Wave
1 kV serial mode IEC 60947-6-2; 2 kV common mode IEC 60947-6-2
Relay Application
Motor control; Motor protection
IP Rating
IP20
Description
Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 110-220V DC, 110-240V AC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1, Compatible with Grainger Part Number 5AB63, 5AB64, Maximum Operating Temperature 158 Degrees F, Minimum Operating Temperature -13 Degrees F