Key Features

Minimum Overload Relay Current Setting
3:00 AM
Maximum Overload Relay Current Setting
12:00 AM
Trip Class
10
Maximum Voltage Rating
690V AC
Standards
CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1
See all product information
Get a 10% off coupon
Free 30-day returns Return Policy
Get 30 days to pay with Net 30 Apply Now
Unlock tax-exempt savings Add Tax Exemption

Specifications

Product Information

MFR #
LUCA12FU
Zoro #
G0477821
UPC #
785901221913
Country of Origin
Korea, Republic of

Dimensions

Width
45 mm
Depth
60 mm
Height
66 mm
Body Height - Relay
2.6 in
Overall Height - Relay
2.6 in
Body Depth - Relay
2.36 in

Details

Item
Overload Module
Minimum Overload Relay Current Setting
3:00 AM
Maximum Overload Relay Current Setting
12:00 AM
Trip Class
10
Maximum Voltage Rating
690V AC
Standards
CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1
Coil Volts
110 to 240V AC; 110 to 220V DC
Number of Poles
3
Hz
40 to 60 Hz
Features
Protection against overload and short-circuit; Manual reset; Earth fault protection; Protection against phase failure and phase imbalance; Free of Halogen, Mercury & Pvc; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
Separate Mounting
No
Trip Class - Overload
10
Kit Required for Retrofit Mtg.
No
Sensing Method
Thermal
Frame / Series / Class / Code
Class 10
Use With - Contactors and Starters
Mfr. Series LUA1C Contactors
Weight
0.135 kg
Reset Type
Manual
Coil Voltage
110-220V DC, 110-240V AC
Compatible with Series
TeSys Ultra
Minimum Operating Temperature
-13 Degrees F
Phase
Three
Maximum Operating Temperature
158 Degrees F
Compatible with Manufacturer Model Number
LUB12, LUB32, LUB38
Maximum Rated Motor Current Adjustment
12 A
Minumum Rated Motor Current Adjustment
3 A
Compatible Manufacturer Model Number
LUB12, LUB32, LUB38
Motor Power KW
5.5 kW 400 to 440 V AC 50/60 Hz; 5.5 kW 500 V AC 50/60 Hz; 9 kW 690 V AC 50/60 Hz
Rated Insulation Voltage
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
Main Function Available
Protection against overload and short-circuit; Manual reset; Earth fault protection; Protection against phase failure and phase imbalance
Resistance To Radiated Fields
9.14 V/m (10 V/m) 3 IEC 61000-4-3
Immunity To Microbreaks
3 ms
Tripping Threshold
14.2 x Ir +/- 20%
Compatibility Code
LUCA
Ambient Air Temperature For Operation
-13 to 158°F (-25 to 70°C)
Product Compatibility
Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12FU; Reversing contactor breaker LU2B32FU; Reversing contactor breaker LU2B38FU
Phase Failure Sensitivity
Yes
Operating Altitude
6561.68 ft (2000 m)
Typical Current Consumption
280 mA 110 to 240 V AC I maximum while closing with LUB12; 280 mA 110 to 240 V AC I maximum while closing with LUB32; 280 mA 110 to 240 V AC I maximum while closing with LUB38; 280 mA 110 to 220 V DC I maximum while closing with LUB12; 280 mA 110 to 220 V DC I maximum while closing with LUB32; 280 mA 110 to 220 V DC I maximum while closing with LUB38; 35 mA 110 to 240 V AC I rms sealed with LUB12; 25 mA 110 to 240 V AC I rms sealed with LUB32; 25 mA 110 to 240 V AC I rms sealed with LUB38; 35 mA 110 to 220 V DC I rms sealed with LUB12; 25 mA 110 to 220 V DC I rms sealed with LUB32; 25 mA 110 to 220 V DC I rms sealed with LUB38
Control Circuit Voltage Limits
88 to 264 V AC 110 to 240 V in operation; 88 to 242 V DC 110 to 220 V in operation; 55 V AC 110 to 240 V drop-out; 55 V DC 110 to 220 V drop-out
Fixing Mode
Plug-in front face)
Operating Time
35 ms opening with LUB12 control circuit; 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 50 ms closing with LUB12 control circuit; 50 ms closing with LUB32 control circuit; 50 ms closing with LUB38 control circuit
Utilisation Category
AC-41; AC-43; AC-44
Protective Treatment
TH IEC 60068
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Load Type
3-phase motor self-cooled
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
Immunity To Voltage Dips
70% / 500 ms IEC 61000-4-11
Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
Ambient Air Temperature For Storage
-40 to 185°F (-40 to 85°C)
Product Specific Application
Basic protection requirements for motor starters: overload and short-circuit
Rated Operational Voltage
690 V AC
Product Certifications
CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
Fire Resistance
1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
Immunity To Radioelectric Fields
10 V IEC 61000-4-6
Shock Resistance
10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
Vibration Resistance
2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Heat Dissipation
2 W control circuit with LUB12; 3 W control circuit with LUB32; 3 W control circuit with LUB38
Thermal Overload Class
Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2; Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Product Or Component Type
Standard control unit
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
Non-Dissipating Shock Wave
1 kV serial mode IEC 60947-6-2; 2 kV common mode IEC 60947-6-2
Relay Application
Motor control; Motor protection
IP Rating
IP20
Trip Clss
10
For Manufacturer Part Number
LUB12, LUB32, LUB38
Compatible with Mfr. Model Number
LUB12, LUB32, LUB38

Description

Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 110-220V DC, 110-240V AC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards CSA C22.2 No 60947-4-1, EN 60947-6-2, IEC 60947-6-2, REACH, RoHS, UL Listed 60947-4-1, For Grainger Part Number 5AB63, 5AB64, Maximum Operating Temperature 158 Degrees F, Minimum Operating Temperature -13 Degrees F

Ratings & reviews

3 reasons you can count on us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.