480VAC Non-Reversing Magnetic Contactor 3P 45A NEMA 2

  • Mfr # 8502SDO2V06
  • Zoro # G0920875
product price: 
$
823.99
/ea
Free Shipping & Returns

Key Features

Action
Non-Reversing
Full Load Amps
45 A
Number of Poles
3
NEMA Contactor Size
2
Reversing
No
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
8502SDO2V06
Zoro #
G0920875
UPC #
785901881605
Country of Origin
Mexico
Item
NEMA Magnetic Contactor
Action
Non-Reversing
Full Load Amps
45 A
Number of Poles
3
Coil Volts
480V AC
Reversing
No
HP @ 3 Phase - 208V
10 hp
HP @ 3 Phase - 575V
25 hp
HP @ 3 Phase - 240V
15 hp
HP @ 3 Phase - 480V
25 hp
Enclosure NEMA Rating
No Enclosure
Hz
50/60 Hz
Frame / Series / Class / Code
Class 8502
Standards
CSA, UL E78351 CCN NLDX
Series
8502
Auxiliary Contact Form
Auxiliary Contacts Not Included
Poles Description
3P
Product Certifications
UL listed file E78351 CCN NLDX || CSA
Control Type
no control units
Nema Degree Of Protection
not rated (open device)
Local Signalling
no indicator
[Uc] Control Circuit Voltage
480 V AC 60 Hz || 440 V AC 50 Hz
[Ue] Rated Operational Voltage
600 V AC
Electrical Connection
screw clamp terminals
Contactor Application
non-reversing
Product Or Component Type
contactor
Phase
Three
Product Compatibility
circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC || fuse J 100 A maximum, SCCR: 100 kA at 600 V AC || fuse T 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC
Control Circuit
common control circuit
Line Rated Current
45 A
Auxiliary Contact Composition
without
Rated Power In Hp
10 HP 200 V AC || 15 HP 230 V AC || 25 HP 460 V AC || 25 HP 575 V AC
Full Load Current - Inductive
45 A
Number of Auxillary Contacts
0
Embedded Surge Suppressor
No
Maximum Voltage Rating
600V AC
Contactor Style
NEMA
Horsepower @ Three Phase - 240V AC
15 hp
Terminal Connection Type
Screw Clamp Terminals
NEMA Enclosure Rating
No Enclosure
Horsepower @ Single Phase - 240V AC
15 hp
Includes Auxiliary Contacts
No
Horsepower @ Three Phase - 600V AC
25 hp
Horsepower @ Three Phase - 208V AC
10 hp
Horsepower @ Three Phase - 480V AC
25 hp
Reversing Capability
Non-Reversing
Coil Voltage
480V AC
Frequency
50/60 Hz
Certifications
UL listed file E78351 CCN NLDX; CSA
Horsepower Rating
10 HP 200 V AC; 15 HP 230 V AC; 25 HP 460 V AC; 25 HP 575 V AC
Short Circuit Current Rating
Circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC; Fuse J 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse T 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC

Dimensions

NEMA Contactor Size
2
Height
5.13 in
Width
4.31 in
Depth
4.94 in
NEMA Size
2
Overall Width
4.31 in
Overall Depth
4.94 in
Overall Height
5.13 in

Description

NEMA Magnetic Contactor, Auxiliary Contact Form Auxiliary Contacts Not Included, NEMA Enclosure Rating No Enclosure, NEMA Size 2, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 45 A, Reversing Capability Non-Reversing, Overall Height 5.13 in, Overall Width 4.31 in, Terminal Connection Type Screw Clamp Terminals, Series 8502, Number of Auxillary Contacts 0, Contactor Style NEMA, Horsepower @ Three Phase - 240V AC 15 hp, Horsepower @ Three Phase - 480V AC 25 hp, Phase Three