Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
240V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LC1D115U7
Zoro #
G2190745
UPC #
785901639121
Country of Origin
Czechia

Dimensions

Working Height
Up to 9842.52 ft
Overall Width
0.47 in
Overall Depth
5.35 in
Overall Height
6.22 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
240V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
100 hp
Reversing
No
Enclosure NEMA Rating
No Enclosure
Series
TeSys Deca
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Mechanical Durability
8 Mcycles
Operating Speed
2400 cycles per hr
Inrush VA
280 to 350 VA
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Hold VA
2 to 18 VA
Fire Rating
UL 94 V1
Switching Current
5 mA (Signalling Circuit)
Impedance
0.6 mOhm
Operating Time
6 to 20 ms (Opening), 20 to 50 ms (Closing)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Electrical Durability
0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V); 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Net Weight
2.5 kg
Overvoltage Category
CAT III
IP Rating
IP20
Rated Breaking Capacity
1100 A @ 440V
Max. Operating Watts
30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Includes Protective Cover
Yes
Watts Loss
3 to 8W
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Application
Motor Control, Resistive Load
Switching Voltage
17 V (Signalling Circuit)
Fuse Amps
250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Rated Making Capacity
1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Impulse Withstand Voltage
8 kV
Non-Overlap Time
1.5 ms
Horsepower @ Three Phase - 600V AC
100 hp
Horsepower @ Single Phase - 240V AC
2 hp
Mechanical Operating Durability
8,000,000
Number of Normally Open Main Contacts
3
Mounting Style
DIN Rail, Plate
NEMA Enclosure Rating
No Enclosure
Maximum Voltage Rating
1000V AC
Embedded Surge Suppressor
Yes
Phase
Three
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Three Phase - 240V AC
40 hp
Frequency
50/60 Hz
Contactor Style
IEC
Maximum Operating Temperature
140 Degrees F
Electrical Operating Durability
800,000, 950,000
Horsepower @ Three Phase - 208V AC
30 hp
Full Load Current - Resistive
200 A
Horsepower @ Three Phase - 480V AC
75 hp
Minimum Operating Temperature
-40 Degrees F
Full Load Current - Inductive
115 A
Includes Auxiliary Contacts
Yes
Conventional Free Air Thermal Current
200 A (at 60°C Power Circuit)

Description

The SQUARE D - IEC Magnetic Contactor is intended for use in motor control and resistive load applications. It operates with a coil voltage of 240V AC, making it compatible with a variety of industrial settings. The contactor features screw clamp terminals for electrical connection and has an auxiliary contact form of 1NC/1NO. Its depth measures at 5.12 inches, while its height stands at 4.33 inches, providing compactness for easy installation.

Key Features:

  • Non-Reversing Action: This feature indicates that the magnetic contactor is designed to operate in one direction.
  • Coil Voltage: Rated for operation at 240V AC, this specification suggests compatibility within certain power environments.
  • Screw Clamp Terminals: These are intended to facilitate electrical connections. Safety and efficiency depend on proper installation and usage.
  • Auxiliary Contact Form (1NC/1NO): This configuration is intended to add potential versatility through additional circuit options.
  • Compact Dimensions (Depth: 5.12in; Height: 4.33in): These dimensions suggest compatibility with a range of installation spaces. Ease of fitting depends on specific space constraints.
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.