Shop SQUARE D

IEC Magnetic Contactor, 1NC/1NO, 480V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D25T7
  • Zoro # G2244435

product price: 
$
162.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
480V AC
Number of Poles
3
Full Load Amps-Inductive
25 A
Full Load Amps-Resistive
40 A
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
LC1D25T7
Zoro #
G2244435
UPC #
785901207146
Country of Origin
Indonesia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
480V AC
Number of Poles
3
Full Load Amps-Inductive
25 A
Full Load Amps-Resistive
40 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
3
Reversing
No
Frame / Series / Class / Code
TeSys
HP @ 3 Phase - 575V
20 hp
Series
TeSys Deca
Inrush VA
70 VA
Overvoltage Category
CAT III
Application
Motor Control, Resistive Load
Operating Speed
3600 cycles per hr
Shock Resistance
8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Watts Loss
2 to 3W
Rated Insulation Volts
600V, 690V
Signalling Circuit Frequency
25 to 400 Hz
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Short-Time Withstand Current
240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fire Rating
UL 94 V1
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Rated Breaking Capacity
450 A @ 440V
Features
Without Built-In Suppressor Module
Electrical Durability
1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Impedance
2 mOhm
Max. Operating Watts
5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Non-Overlap Time
1.5 ms
Net Weight
0.37 kg
Impulse Withstand Voltage
6 kV
Switching Current
5 mA (Signalling Circuit)
IP Rating
IP20
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Mechanical Durability
15 Mcycles
Includes Protective Cover
Yes
Switching Voltage
17 V (Signalling Circuit)
Fuse Amps
10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Tightening Torque
1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Full Load Current - Resistive
40 A
Full Load Current - Inductive
25 A
Contactor Style
IEC
Horsepower @ Three Phase - 600V AC
20 hp
Embedded Surge Suppressor
No
NEMA Enclosure Rating
No Enclosure
Resistance Properties
Fire Resistant, Insulation Resistant
Maximum Operating Temperature
140 Degrees F
Electrical Operating Durability
1,400,000, 1,650,000
Mechanical Operating Durability
15,000,000
Minimum Operating Temperature
-40 Degrees F
Frequency
50/60 Hz
Horsepower @ Single Phase - 240V AC
3 hp
Maximum Voltage Rating
690V AC
Number of Normally Open Main Contacts
3
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 240V AC
7 1/2 hp
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 120V AC
2 hp
Phase
Three
Horsepower @ Three Phase - 480V AC
15 hp
Horsepower @ Three Phase - 208V AC
7 1/2 hp
Utilisation Category
AC-3; AC-1; AC-4; AC-3e
Control Circuit Voltage
480 V AC 50/60 Hz
Pole Contact Composition
3 NO
Maximum Operating Rate
3600 cyc/h 140°F (60°C)
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Heat Dissipation
2 to 3 W at 50/60 Hz
Pollution Degree
3
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms)
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Contactor Application
Motor control; Resistive load
Protective Treatment
THIEC 60068-2-30
Contact Compatibility
M2
Compatibility Code
LC1D
Control Circuit Type
AC 50/60 Hz
Rated Operational Current
25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Protective Cover
With
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Power Dissipation Per Pole
3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
3.35 in
Overall Width
1.77 in
Overall Depth
3.62 in

Description

The SQUARE D - IEC Magnetic Contactor is a non-reversing, three-pole contactor intended for use in motor control and resistive load applications. It operates with a coil voltage of 480V AC and features an auxiliary contact configuration of 1NO/1NC. The contactor has an average impedance of 2 mOhm at Ith 40 A 50 Hz for the power circuit and has been tested under conditions similar to IACS E10 exposure to damp heat and IEC 60947-1 Annex Q category D exposure to damp heat.

Key Features:

  • Compatible with screw clamp terminals for both control circuits (flexible/solid without cable end) and power circuits (flexible/solid with or without cable end).
  • Electrical durability tests have shown results ranging from 1.4 Mcycles (40 A, AC-1, Less than 440 V) up to approximately 1.65 Mcycles (25 A, AC-3e, Less than 440 V).
  • Operating temperature should not exceed140 Degrees F.
  • Includes a protective cover.
  • Insulation voltage has been tested up until Power circuit:690 V as per the guidelines of the relevant IEC standards; Signalling circuit:690V as per the guidelines of the relevant IEC standards.
  • Mechanical durability tests have shown results reaching approximately15 Mcycles.
  • Mounting style supports DIN Rail or Plate mounting options.
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      13 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      4.5 million products ship in 1 day.

    • Stretch your budget further.

      Everyday low prices on the brands you love.