Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
125 hp
Enclosure NEMA Rating
No Enclosure
Includes Protective Cover
Yes
Application
Motor Control, Resistive Load
Rated Breaking Capacity
1400 A @ 440V
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Max. Operating Watts
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Switching Voltage
17 V (Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Signalling Circuit Frequency
25 to 400 Hz
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Switching Current
5 mA (Signalling Circuit)
Mechanical Durability
8 Mcycles
Fuse Amps
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Impulse Withstand Voltage
8 kV
Electrical Durability
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Overvoltage Category
CAT III
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Operating Speed
1200 cycles per hr
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Full Load Current - Resistive
200 A
Includes Auxiliary Contacts
Yes
Maximum Voltage Rating
1000V AC
NEMA Enclosure Rating
No Enclosure
Maximum Operating Temperature
140 Degrees F
Horsepower @ Three Phase - 208V AC
40 hp
Full Load Current - Inductive
150 A
Horsepower @ Three Phase - 480V AC
100 hp
Horsepower @ Single Phase - 240V AC
3 hp
Mounting Style
DIN Rail, Plate
Mechanical Operating Durability
8,000,000
Electrical Operating Durability
1,000,000, 850,000
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 600V AC
125 hp
Number of Normally Open Main Contacts
3
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Three Phase - 240V AC
50 hp
Embedded Surge Suppressor
Yes
Conventional Free Air Thermal Current
200 A (at 60°C Power Circuit)