- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 24V DC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 12 A
- Full Load Amps-Resistive
- 25 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- Enclosure NEMA Rating
- No Enclosure
- HP @ 3 Phase - 575V
- 10 hp
- HP @ 1 Phase - 230V
- 2
- Includes
- Electrical Interlock
- Reversing
- Yes
- Series
- TeSys Deca
- Net Weight
- 1.027 kg
- Switching Voltage
- 17 V (Signalling Circuit)
- Impulse Withstand Voltage
- 6 kV
- Electrical Durability
- 2 Mcycles (12 A, AC-3, Less than 440 V); 0.8 Mcycles (25 A, AC-1, Less than 440 V)
- Rated Short-Time Withstand Current
- 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Rated Breaking Capacity
- 250 A @ 440V
- Impedance
- 2.5 mOhm
- IP Rating
- IP20
- Operating Time
- 53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening)
- Mechanical Durability
- 30 Mcycles
- Control Circuit Voltage Limits
- Drop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
- Signalling Circuit Frequency
- 25 to 400 Hz
- Features
- Built-In Bi-Directional Peak Limiting Diode Suppressor; Preassembled with Reversing Power Busbar
- Operating Speed
- 3600 cycles per hr
- Rated Making Capacity
- 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
- Fuse Amps
- 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Non-Overlap Time
- 1.5 ms
- Environmental Attributes
- Mercury Free, PVC Free, Pollution Degree 3
- Rated Insulation Volts
- 600/690V
- Includes Protective Cover
- Yes
- Tightening Torque
- 1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
- Shock Resistance
- 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
- Application
- Motor Control, Resistive Load
- Max. Operating Watts
- 3 kW (at 220 to 230V AC 50 Hz), 5.5 kW (at 380 to 400V AC 50 Hz), 5.5 kW (at 415 to 440V AC 50 Hz), 7.5 kW (at 500V AC 50 Hz), 7.5 kW (at 660 to 690V AC 50 Hz)
- Fire Rating
- UL 94 V1
- Overvoltage Category
- CAT III
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Switching Current
- 5 mA (Signalling Circuit)
- Maximum Operating Temperature
- 140 Degrees F
- Horsepower @ Three Phase - 600V AC
- 10 hp
- Number of Normally Open Main Contacts
- 3
- Horsepower @ Three Phase - 480V AC
- 7 1/2 hp
- NEMA Enclosure Rating
- No Enclosure
- Includes Auxiliary Contacts
- Yes
- Maximum Voltage Rating
- 690V AC
- Mounting Style
- DIN Rail, Plate
- Horsepower @ Three Phase - 240V AC
- 3 hp
- Frequency
- 50/60 Hz
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Horsepower @ Three Phase - 208V AC
- 3 hp
- Full Load Current - Inductive
- 12 A
- Contactor Style
- IEC
- Embedded Surge Suppressor
- Yes
- Horsepower @ Single Phase - 120V AC
- 1 hp
- Minimum Operating Temperature
- -40 Degrees F
- Mechanical Operating Durability
- 30,000,000
- Horsepower @ Single Phase - 240V AC
- 2 hp
- Full Load Current - Resistive
- 25 A
- Electrical Operating Durability
- 2,000,000, 800,000
- Front Cover
- With
- Contactor Application
- Motor control; Resistive load
- Control Circuit Type
- DC standard
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C)) for signalling circuit; 25 A (at 140°F (60°C)) for power circuit
- Hold-In Power Consumption in W
- 5.4 W 68°F (20°C)
- Interlocking Type
- Mechanical
- Climatic Withstand
- IACS E10; IEC 60947-1 Annex Q category D
- Utilisation Category
- AC-1; AC-3; AC-3e
- Mechanical Robustness
- Vibrations contactor open2 Gn, 5 to 300 Hz; Vibrations contactor closed4 Gn, 5 to 300 Hz; Shocks contactor open10 Gn for 11 ms; Shocks contactor closed15 Gn for 11 ms
- Power Dissipation Per Pole
- 1.56 W AC-1; 0.36 W AC-3; 0.36 W AC-3e
- Time Constant
- 28 ms
- Inrush Power in W
- 5.4 W 68°F (20°C)
- Rated Operational Current
- 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Protective Treatment
- TH IEC 60068-2-30
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Product Name
- TeSys D; TeSys Deca
- Pollution Degree
- 3
- Ambient Air Temperature For Storage
- -76 to 176°F (-60 to 80°C)
- Device Presentation
- Preassembled with reversing power busbar
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
- Pole Contact Composition
- 3 NO