- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 480V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 115 A
- Full Load Amps-Resistive
- 200 A
- Reversing Capability
- Non-Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- Coil Volts
- 480 V AC
- Action
- Non-Reversing
- HP @ 3 Phase - 240V
- 40 hp
- Reversing
- No
- HP @ 3 Phase - 575V
- 100 hp
- Aux. Contact Configuration
- 1NO/1NC
- HP @ 3 Phase - 480V
- 75 hp
- HP @ 3 Phase - 208V
- 30 hp
- Hz
- 50/60
- Enclosure NEMA Rating
- No Enclosure
- Series
- TeSys Deca
- Operating Time
- 6 to 20 ms (Opening), 20 to 50 ms (Closing)
- Rated Breaking Capacity
- 1100 A @ 440V
- Switching Current
- 5 mA (Signalling Circuit)
- Max. Operating Watts
30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
- Rated Making Capacity
- 1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
- Watts Loss
- 3 to 8W
- Includes Protective Cover
- Yes
- Shock Resistance
- 15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
- Electrical Durability
- 0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V); 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
- Fire Rating
- UL 94 V1
- Thermal Amperage
- 200 A (at 60°C Power Circuit)
- Fuse Amps
- 250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
- Rated Short-Time Withstand Current
- 250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Max. Temperature
- 850°C
- Impulse Withstand Voltage
- 8 kV
- Application
- Motor Control, Resistive Load
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Environmental Attributes
- Mercury Free, PVC Free, Pollution Degree 3
- Switching Voltage
- 17 V (Signalling Circuit)
- Non-Overlap Time
- 1.5 ms
- Inrush VA
- 300 VA
- Net Weight
- 2.5 kg
- Impedance
- 0.6 mOhm
- Features
- Without Built-In Suppressor Module
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Rated Insulation Volts
- 600/1000V (Power Circuit), 600/690V (Signalling Circuit)
- Tightening Torque
- 1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
- Rated Voltage
- 1000V AC, 300V DC
- Mounts On
- Plate, Rail
- Electrical Connection
- Screw Clamp Terminals
- Hold VA
- 22 VA
- Control Circuit Voltage Limits
- Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 60 Hz); Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz)
- Mechanical Durability
- 8 Mcycles
- Operating Speed
- 2400 cycles per hr
- Signalling Circuit Frequency
- 25 to 400 Hz
- IP Rating
- IP20
- Overvoltage Category
- CAT III
- Minimum Operating Temperature
- -40 Degrees F
- Electrical Operating Durability
- 800,000, 950,000
- Horsepower @ Three Phase - 208V AC
- 30 hp
- Includes Auxiliary Contacts
- Yes
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Mounting Style
- DIN Rail, Plate
- Contactor Style
- IEC
- Horsepower @ Three Phase - 600V AC
- 100 hp
- Full Load Current - Resistive
- 200 A
- Horsepower @ Three Phase - 240V AC
- 40 hp
- Horsepower @ Three Phase - 480V AC
- 75 hp
- Horsepower @ Single Phase - 240V AC
- 2 hp
- Maximum Voltage Rating
- 1000V AC
- Number of Normally Open Main Contacts
- 3
- Frequency
- 60 Hz
- Maximum Operating Temperature
- 140 Degrees F
- Full Load Current - Inductive
- 115 A
- Phase
- Three
- Embedded Surge Suppressor
- No
- NEMA Enclosure Rating
- No Enclosure
- Mechanical Operating Durability
- 8,000,000
- Permissible Ambient Air Temperature Around The Device
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
- Rated Operational Voltage
- Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Rated Impulse Withstand Voltage
- 8 kV IEC 60947
- IP Degree Of Protection
- IP20 front face IEC 60529
- Utilisation Category
- AC-3; AC-1; AC-4; AC-3e
- Power Dissipation Per Pole
- 24 W AC-1; 7.9 W AC-3; 7.9 W AC-3e
- Compatibility Code
- LC1D
- Heat Dissipation
- 3 to 8 W at 60 Hz
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Associated Fuse Rating
- 250 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 200 A gG at Less than or Equal to 690 V coordination type 2 for power circuit; 10 A gG for signalling circuit
- Pollution Degree
- 3
- Connections - Terminals
Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: solid without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: solid without cable end
- Protective Cover
- With
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Climatic Withstand
- IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
- Motor Power KW
30 kW at 220 to 230 V AC 50/60 Hz (AC-3); 55 kW at 380 to 400 V AC 50/60 Hz (AC-3); 59 kW at 415 to 440 V AC 50/60 Hz (AC-3); 75 kW at 500 V AC 50/60 Hz (AC-3); 80 kW at 660 to 690 V AC 50/60 Hz (AC-3); 65 kW at 1000 V AC 50/60 Hz (AC-3); 18.5 kW at 400 V AC 50/60 Hz (AC-4); 30 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 55 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 59 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 75 kW at 500 V AC 50/60 Hz (AC-3e); 80 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 65 kW at 1000 V AC 50/60 Hz (AC-3e)
- Rated Insulation Voltage
- Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Mounting Support
- Rail; Plate
- Maximum Operating Rate
- 2400 cyc/h 140°F (60°C)
- Protective Treatment
- THIEC 60068-2-30
- Maximum Horse Power Rating
- 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Conventional Free Air Thermal Current
- 200 A (at 140°F (60°C)) for power circuit
- Contactor Application
- Motor control; Resistive load
- Control Circuit Voltage
- 480 V AC 60 Hz
- Hold-In Power Consumption in VA
- 22 VA 60 Hz cos phi 0.3 (at 68°F (20°C))
- Rated Short Time Withstand Current
250 A 104°F (40°C) - 10 min for power circuit; 550 A 104°F (40°C) - 1 min for power circuit; 950 A 104°F (40°C) - 10 s for power circuit; 1100 A 104°F (40°C) - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
- Control Circuit Type
- AC 60 Hz
- IRMS Rated Making Capacity
- 1260 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Average Impedance
- 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- Pole Contact Composition
- 3 NO
- Inrush Power in VA
- 300 VA 60 Hz cos phi 0.8 (at 68°F (20°C))
- Poles Description
- 3P
- Contact Compatibility
- M13
- Product Or Component Type
- Contactor
- Minimum Switching Current
- 5 mA for signalling circuit
- Flame Retardance
- V1 conforming to UL 94
- Mechanical Robustness
- Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
- Rated Operational Current
- 200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
- Minimum Switching Voltage
- 17 V for signalling circuit
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Insulation Resistance
- Greater than 10 MOhm for signalling circuit
- Product Certifications
- CSA; GOST; CCC; UL; RINA; BV; LROS (Lloyds register of shipping); DNV; GL; UKCA; CE