  • Mfr # LC1D150T7
  • Zoro # G2432473

product price: 
$
862.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
480V AC
Number of Poles
3
Full Load Amps-Inductive
150 A
Full Load Amps-Resistive
200 A
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
LC1D150T7
Zoro #
G2432473
UPC #
785901299431
Country of Origin
Czechia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
480V AC
Number of Poles
3
Full Load Amps-Inductive
150 A
Full Load Amps-Resistive
200 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Reversing
No
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
125 hp
Series
TeSys Deca
Fire Rating
UL 94 V1
Electrical Durability
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Inrush VA
280 to 350 VA
Net Weight
2.5 kg
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Switching Voltage
17 V (Signalling Circuit)
Watts Loss
3 to 4.5W
IP Rating
IP20
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Impulse Withstand Voltage
8 kV
Rated Breaking Capacity
1400 A @ 440V
Mechanical Durability
8 Mcycles
Signalling Circuit Frequency
25 to 400 Hz
Switching Current
5 mA (Signalling Circuit)
Application
Motor Control, Resistive Load
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Overvoltage Category
CAT III
Impedance
0.6 mOhm
Hold VA
2 to 18 VA
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Fuse Amps
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Max. Operating Watts
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Includes Protective Cover
Yes
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Non-Overlap Time
1.5 ms
Operating Speed
1200 cycles per hr
Maximum Voltage Rating
1000V AC
Contactor Style
IEC
Frequency
50/60 Hz
Horsepower @ Three Phase - 480V AC
100 hp
Horsepower @ Three Phase - 208V AC
40 hp
Horsepower @ Three Phase - 240V AC
50 hp
Full Load Current - Resistive
200 A
Includes Auxiliary Contacts
Yes
Mechanical Operating Durability
8,000,000
Number of Normally Open Main Contacts
3
Horsepower @ Single Phase - 240V AC
5 hp
NEMA Enclosure Rating
No Enclosure
Full Load Current - Inductive
150 A
Phase
Three
Horsepower @ Three Phase - 600V AC
125 hp
Mounting Style
DIN Rail, Plate
Embedded Surge Suppressor
Yes
Resistance Properties
Fire Resistant, Insulation Resistant
Minimum Operating Temperature
-40 Degrees F
Electrical Operating Durability
1,000,000, 850,000
Maximum Operating Temperature
140 Degrees F
Conventional Free Air Thermal Current
200 A (at 60°C Power Circuit)

Dimensions

Working Height
Up to 9842.52 ft
Overall Width
0.47 in
Overall Height
6.22 in
Overall Depth
5.35 in

Description

The SQUARE D IEC Magnetic Contactor is a three-pole, non-reversing, electrically operated switch rated for switching applications within specified load types and voltages in AC circuits. It is equipped with a 480 V AC coil; includes auxiliary contacts as specified; features screw clamp terminals; includes protective cover (not an enclosure). This IEC-style contactor is part of the TeSys Deca line and is intended for use in control panels requiring compatible component sizes and configurations.

Key features

  • Contactor type/series: Conforms to IEC standards for magnetic contactors, series TeSys Deca; specifications include number of poles and auxiliary contacts
  • Coil and ratings: Rated for operation at specified voltage ranges within the product's electrical ratings
  • Contacts: Configured with main contacts as specified, auxiliary contacts as indicated
  • Enclosure and mounting: Rated for installation in environments conforming to IP20 standards under normal conditions. Compatibility depends on proper mounting methods.
  • Durability and protection: Durability figures are based on testing parameters but do not guarantee performance over time or under all conditions. The surge suppressor is included per specifications.
  • Power and weight: Power ratings are based on standard test conditions within the product’s electrical capabilities. Actual performance may vary depending on application conditions.
  • Standards and ratings: Complies with listed standards applicable to its designations, but does not imply suitability beyond those standards or guarantee specific safety outcomes.
  • Other ratings: Shock/operating temperature values provided (Maximum Operating Temperature 140°F; Max. Temperature 850°C)