Square D

IEC Magnetic Contactor, 3 Poles, 480 V AC, 25 A, Reversing: No


product price: $174.99
/ea
Free Shipping & Returns

Free Shipping on orders over $50
Free 30-Day Returns

Key Features

  • Full Load Amps-Inductive 25 A
  • Action Non-Reversing
  • Full Load Amps-Resistive 40 A
  • Number of Poles 3
  • Coil Volts 480 V AC
See all product information

Product Information

Dimensions

Height 3.36 in
Width 1.77 in
Depth 3.62 in
Working Height Up to 9842.52 ft
Overall Height 3.35 in
Overall Width 1.77 in
Overall Depth 3.62 in

Details

Item IEC Magnetic Contactor
Full Load Amps-Inductive 25 A
Action Non-Reversing
Full Load Amps-Resistive 40 A
Number of Poles 3
Coil Volts 480 V AC
Reversing No
HP @ 1 Phase - 230V 3
HP @ 1 Phase - 120V 2 hp
HP @ 1 Phase - 240V 3 hp
HP @ 3 Phase - 208V 7 1/2 hp
HP @ 3 Phase - 240V 7 1/2 hp
HP @ 3 Phase - 575V 20 hp
Enclosure NEMA Rating No Enclosure
HP @ 3 Phase - 480V 15 hp
Aux. Contact Configuration 1NO/1NC
Hz 50/60
Auxiliary Contact Form 1NO/1NC
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
Series TeSys Deca
Inrush VA 70 VA
Thermal Amperage 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)
Overvoltage Category CAT III
Application Motor Control, Resistive Load
Operating Speed 3600 cycles per hr
Shock Resistance 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Watts Loss 2 to 3W
Rated Insulation Volts 600/690V
Signalling Circuit Frequency 25 to 400 Hz
Electrical Connection Screw Clamp Terminals
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Rated Short-Time Withstand Current 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fire Rating UL 94 V1
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Rated Breaking Capacity 450 A @ 440V
Features Without Built-In Suppressor Module
Electrical Durability 1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Impedance 2 mOhm
Max. Operating Watts 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Non-Overlap Time 1.5 ms
Net Weight 0.37 kg
Impulse Withstand Voltage 6 kV
Switching Current 5 mA (Signalling Circuit)
IP Rating IP20
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Mounts On Plate, Rail
Max. Temperature 850°C
Rated Voltage 690V AC, 300V DC
Mechanical Durability 15 Mcycles
Includes Protective Cover Yes
Switching Voltage 17 V (Signalling Circuit)
Fuse Amps 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Tightening Torque 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Full Load Current - Resistive 40 A
Full Load Current - Inductive 25 A
Contactor Style IEC
Horsepower @ Three Phase - 600V AC 20 hp
Embedded Surge Suppressor No
NEMA Enclosure Rating No Enclosure
Resistance Properties Fire Resistant, Insulation Resistant
Maximum Operating Temperature 140 Degrees F
Electrical Operating Durability 1,400,000, 1,650,000
Mechanical Operating Durability 15,000,000
Minimum Operating Temperature -40 Degrees F
Frequency 50/60 Hz
Coil Voltage 480V AC
Reversing Capability Non-Reversing
Horsepower @ Single Phase - 240V AC 3 hp
Maximum Voltage Rating 690V AC
Number of Normally Open Main Contacts 3
Mounting Style DIN Rail, Plate
Terminal Connection Type Screw Clamp Terminals
Horsepower @ Three Phase - 240V AC 7 1/2 hp
Includes Auxiliary Contacts Yes
Horsepower @ Single Phase - 120V AC 2 hp
Phase Three
Number of Auxillary Contacts 2
Horsepower @ Three Phase - 480V AC 15 hp
Horsepower @ Three Phase - 208V AC 7 1/2 hp
Connections - Terminals Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1.5 to 10 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: solid without cable end
Utilisation Category AC-3; AC-1; AC-4; AC-3e
Control Circuit Voltage 480 V AC 50/60 Hz
Pole Contact Composition 3 NO
Minimum Switching Voltage 17 V for signalling circuit
Maximum Operating Rate 3600 cyc/h 140°F (60°C)
IP Degree Of Protection IP20 front face IEC 60529
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Product Certifications DNV; CSA; RINA; GOST; LROS (Lloyds register of shipping); CCC; GL; BV; UL; UKCA
Inrush Power in VA 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Poles Description 3P
Heat Dissipation 2 to 3 W at 50/60 Hz
Pollution Degree 3
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Rated Impulse Withstand Voltage 6 kV IEC 60947
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms)
Conventional Free Air Thermal Current 10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Permissible Ambient Air Temperature Around The Device -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Insulation Resistance Greater than 10 MOhm for signalling circuit
Contactor Application Motor control; Resistive load
Auxiliary Contact Composition 1 NO + 1 NC
IRMS Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947
Flame Retardance V1 conforming to UL 94
Product Or Component Type Contactor
Motor Power KW 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3); 15 kW at 500 V AC 50/60 Hz (AC-3); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3); 5.5 kW at 400 V AC 50/60 Hz (AC-4); 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 15 kW at 500 V AC 50/60 Hz (AC-3e); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Protective Treatment THIEC 60068-2-30
Contact Compatibility M2
Compatibility Code LC1D
Control Circuit Type AC 50/60 Hz
Rated Short Time Withstand Current 240 A 104°F (40°C) - 10 s for power circuit; 380 A 104°F (40°C) - 1 s for power circuit; 50 A 104°F (40°C) - 10 min for power circuit; 120 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Rated Operational Current 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Maximum Horse Power Rating 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Protective Cover With
Minimum Switching Current 5 mA for signalling circuit
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Average Impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
Mounting Support Plate; Rail
Power Dissipation Per Pole 3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e
Hold-In Power Consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.