BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
1-1/2
HP @ 3 Phase - 575V
10 hp
Reversing
No
Series
TeSys K
Rated Breaking Capacity
110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Mechanical Durability
10 Mcycles
Application
Motor Control, Resistive Load
Switching Current
5 mA (Signalling Circuit)
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Watts Loss
1.3W
Max. Operating Watts
4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Signalling Circuit Frequency
Less Than 400 Hz
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Overvoltage Category
CAT III
Electrical Durability
0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Net Weight
0.18 kg
Tightening Torque
0.8 to 1.3 Nm
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Rated Making Capacity
110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
IP Rating
IP22
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Rated Short-Time Withstand Current
115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Operating Speed
3600 cycles per hr
Inrush VA
30 VA
Impulse Withstand Voltage
8 kV
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts
600/690V
Impedance
3 mOhm
Switching Voltage
17 V (Signalling Circuit)
Hold VA
4.5 VA
Includes Auxiliary Contacts
Yes
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Maximum Voltage Rating
690V AC
Full Load Current - Inductive
12:00 AM
Embedded Surge Suppressor
No
Number of Normally Open Main Contacts
3
Resistance Properties
Insulation Resistant
Electrical Operating Durability
1,300,000, 300,000
Frequency
50/60 Hz
Horsepower @ Three Phase - 600V AC
10 hp
Contactor Style
IEC
Mechanical Operating Durability
10,000,000
Horsepower @ Single Phase - 120V AC
1 hp
Horsepower @ Three Phase - 240V AC
3 hp
Full Load Current - Resistive
20 A
Mounting Style
DIN Rail, Plate
Horsepower @ Single Phase - 240V AC
2 hp
Conventional Free Air Thermal Current
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Description
The SQUARE D IEC Miniature Magnetic Contactor is a 3-pole, non-reversing device with a 24 V AC coil. It is rated for switching applications within specified load types, and it features one normally-open auxiliary contact with screw clamp terminals. The unit is suitable for DIN rail or panel mounting as per installation guidelines and is provided without an enclosure; compatible with environments requiring IP22-rated enclosures.
Coil voltage: 24 V AC
Poles/Main contacts and aux: 3 poles; 3 normally open main contacts; 1 NO auxiliary contact
Reversing: Non-Reversing
Application: Motor control, resistive load
Maximum voltage: 690 V AC
Full Load Amps: 20 A (resistive), 12 A (inductive)
Mounting/Terminals: DIN rail or plate mounting; Screw Clamp terminals