- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 120V AC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 32 A
- Full Load Amps-Resistive
- 50 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- Reversing
- Yes
- Enclosure NEMA Rating
- No Enclosure
- HP @ 1 Phase - 230V
- 5
- HP @ 3 Phase - 575V
- 30 hp
- Series
- TeSys Deca
- Switching Voltage
- 17 V (Signalling Circuit)
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Tightening Torque
- 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
- Hold VA
- 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Features
- Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
- Shock Resistance
- 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
- Signalling Circuit Frequency
- 25 to 400 Hz
- Mechanical Durability
- 15 Mcycles
- Switching Current
- 5 mA (Signalling Circuit)
- Rated Short-Time Withstand Current
- 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Fuse Amps
- 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
- Electrical Durability
- 1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V)
- Operating Speed
- 3600 cycles per hr
- Rated Insulation Volts
- 600/690V
- Impulse Withstand Voltage
- 6 kV
- Application
- Motor Control, Resistive Load
- Impedance
- 2 mOhm
- IP Rating
- IP20
- Inrush VA
- 70 VA
- Environmental Attributes
- Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
- Control Circuit Voltage Limits
- Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
- Watts Loss
- 2 to 3W
- Non-Overlap Time
- 1.5 ms
- Rated Breaking Capacity
- 550 A @ 440V
- Net Weight
- 0.797 kg
- Operating Time
- 12 to 22 ms (Closing), 4 to 19 ms (Opening)
- Fire Rating
- UL 94 V1
- Includes Protective Cover
- Yes
- Overvoltage Category
- CAT III
- Max. Operating Watts
- 7.5 kW (at 220 to 230V AC 50 Hz), 15 kW (at 380 to 400V AC 50 Hz), 15 kW (at 415 to 440V AC 50 Hz), 18.5 kW (at 500V AC 50 Hz), 18.5 kW (at 660 to 690V AC 50 Hz)
- Electrical Operating Durability
- 1,400,000, 1,650,000
- NEMA Enclosure Rating
- No Enclosure
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Number of Normally Open Main Contacts
- 3
- Full Load Current - Resistive
- 50 A
- Mechanical Operating Durability
- 15,000,000
- Horsepower @ Three Phase - 208V AC
- 7 1/2 hp
- Horsepower @ Three Phase - 480V AC
- 20 hp
- Horsepower @ Single Phase - 120V AC
- 2 hp
- Contactor Style
- IEC
- Horsepower @ Single Phase - 240V AC
- 5 hp
- Frequency
- 50/60 Hz
- Maximum Voltage Rating
- 690V AC
- Mounting Style
- DIN Rail, Plate
- Horsepower @ Three Phase - 600V AC
- 30 hp
- Includes Auxiliary Contacts
- Yes
- Full Load Current - Inductive
- 32 A
- Minimum Operating Temperature
- -40 Degrees F
- Horsepower @ Three Phase - 240V AC
- 10 hp
- Embedded Surge Suppressor
- No
- Maximum Operating Temperature
- 140 Degrees F
- Utilisation Category
- AC-3; AC-1
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Ambient Air Temperature For Operation
- -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
- Operating Altitude
- 0 to 9842.52 ft (0 to 3000 m)
- Maximum Operating Rate
- 3600 cyc/h 140°F (60°C)
- Protective Treatment
- TH IEC 60068-2-30
- Interlocking Type
- Mechanical
- Device Presentation
- Preassembled with reversing power busbar
- Pollution Degree
- 3
- Auxiliary Contacts Type
- Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
- Conventional Free Air Thermal Current
- 10 A (at 140°F (60°C)) for signalling circuit; 50 A (at 140°F (60°C)) for power circuit
- Heat Dissipation
- 2 to 3 W 50/60 Hz
- Contactor Application
- Motor control; Resistive load
- Mechanical Robustness
- Vibrations contactor open2 Gn, 5 to 300 Hz; Vibrations contactor closed4 Gn, 5 to 300 Hz; Shocks contactor closed15 Gn for 11 ms; Shocks contactor open8 Gn for 11 ms
- Climatic Withstand
- IACS E10; IEC 60947-1 Annex Q category D
- Power Dissipation Per Pole
- 2 W AC-3; 5 W AC-1
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
- Control Circuit Voltage
- 120 V AC 50/60 Hz
- Fire Resistance
- 1562°F (850°C) IEC 60695-2-1
- Rated Operational Current
- 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
- Inrush Power in VA
- 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
- Control Circuit Type
- AC 50/60 Hz
- Ambient Air Temperature For Storage
- -76 to 176°F (-60 to 80°C)
- Front Cover
- With
- Product Name
- TeSys Deca; TeSys Deca
- Pole Contact Composition
- 3 NO