- Item
- IEC Miniature Magnetic Contactor
- Auxiliary Contact Form
- 1NO
- Coil Voltage
- 24V DC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 12 A
- Full Load Amps-Resistive
- 20 A
- Reversing Capability
- Non-Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 1
- Standards
- CSA, UKCA, UL Listed
- Enclosure NEMA Rating
- No Enclosure
- HP @ 1 Phase - 230V
- 1-1/2
- Reversing
- No
- HP @ 3 Phase - 575V
- 10 hp
- Frame / Series / Class / Code
- TeSys
- Series
- TeSys K
- Operating Speed
- 3600 cycles per hr
- Impedance
- 3 mOhm
- Net Weight
- 0.225 kg
- Rated Making Capacity
- 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
- Fire Rating
- UL 94 V1, NF F 16-101, NF F 16-102
- Switching Current
- 5 mA (Signalling Circuit)
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Control Circuit Voltage Limits
- Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
- Application
- Motor Control, Resistive Load
- Electrical Durability
- 1.3 Mcycles 12 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 12 A AC-3e Less than or Equal to 440 V; 0.3 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 72 A AC-4 Less than or Equal to 440 V
- Mechanical Durability
- 10 Mcycles
- Overvoltage Category
- CAT III
- Switching Voltage
- 17 V (Signalling Circuit)
- Rated Breaking Capacity
- 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
- Impulse Withstand Voltage
- 8 kV
- Rated Insulation Volts
- 600/690V
- Fuse Amps
- 25 A (Power Circuit), 10 A (Signalling Circuit)
- Environmental Attributes
- Mercury Free, Toxic Heavy Metal Free
- Operating Time
- 30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
- Tightening Torque
- 0.8 to 1.3 Nm
- Maximum Voltage Rating
- 690V AC
- Horsepower @ Three Phase - 480V AC
- 7 1/2 hp
- Includes Auxiliary Contacts
- Yes
- Full Load Current - Resistive
- 20 A
- Contactor Style
- IEC
- Frequency
- 50/60 Hz
- Full Load Current - Inductive
- 12 A
- NEMA Enclosure Rating
- No Enclosure
- Horsepower @ Three Phase - 600V AC
- 10 hp
- Resistance Properties
- Insulation Resistant
- Maximum Operating Temperature
- 122 Degrees F
- Number of Normally Open Main Contacts
- 3
- Embedded Surge Suppressor
- No
- Mounting Style
- DIN Rail, Plate
- Horsepower @ Three Phase - 240V AC
- 3 hp
- Mechanical Operating Durability
- 10,000,000
- Horsepower @ Single Phase - 240V AC
- 2 hp
- Minimum Operating Temperature
- -13 Degrees F
- Horsepower @ Single Phase - 120V AC
- 1/2 hp
- Contactor Application
- Resistive load; Motor control
- Ambient Air Temperature For Storage
- -58 to 176°F (-50 to 80°C)
- Hold-In Power Consumption in W
- 3 W 68°F (20°C)
- Control Circuit Type
- DC standard
- Auxiliary Contacts Type
- Instantaneous 1 NO
- Rated Operational Current
- 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
- Maximum Operating Rate
- 3600 cyc/h
- Conventional Free Air Thermal Current
- 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
- Rated Operational Voltage
- Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
- Inrush Power in W
- 3 W 68°F (20°C)
- Heat Dissipation
- 1.3 W
- Utilisation Category
- AC-3; AC-3e; AC-1; AC-4
- Ambient Air Temperature For Operation
- -40 to 158°F (-40 to 70°C) at Uc
- Operating Altitude
- 6561.68 ft (2000 m) without derating
- Safety Reliability Level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Rated Short-Time Withstand Current
115 A (at 50 Degrees C for 1 s Power Circuit), 105 A (at 50 Degrees C for 5 s Power Circuit), 100 A (at 50??C for 10 s Power Circuit), 75 A (at 50 Degrees C for 30 s Power Circuit), 55 A (at 50??C for 1 min Power Circuit), 50 A (at 50 Degrees C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50 Degrees C for 15 min Power Circuit)
- IP Rating
- IP2X
- Pole Contact Composition
- 3 NO