Key Features

  • Full Load Amps-Inductive 12 A
  • Full Load Amps-Resistive 20 A
  • Action Non-Reversing
  • Number of Poles 3
  • Reversing No
See all product information

Product Information

Dimensions

Height 1.77 in
Width 1.77 in
Depth 2.24 in
Working Height 6561.68 ft
Overall Width 1.77 in
Overall Height 2.28 in
Overall Depth 2.24 in

Details

Full Load Amps-Inductive 12 A
Item Miniature IEC Magnetic Contactor
Full Load Amps-Resistive 20 A
Action Non-Reversing
Number of Poles 3
Coil Volts 240 V AC
Reversing No
HP @ 1 Phase - 230V 1-1/2
HP @ 1 Phase - 120V 1/2 hp
HP @ 1 Phase - 240V 2 hp
HP @ 3 Phase - 240V 3 hp
HP @ 3 Phase - 575V 10 hp
Enclosure NEMA Rating No Enclosure
HP @ 3 Phase - 480V 7 1/2 hp
Aux. Contact Configuration 1NO
Hz 50/60
Standards BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Auxiliary Contact Form 1NO
Series TeSys K
Impedance 3 mOhm
Electrical Connection Screw Clamp Terminals
Operating Speed 3600 cycles per hr
Rated Making Capacity 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
Signalling Circuit Frequency Less Than 400 Hz
Application Motor Control, Resistive Load
Rated Short-Time Withstand Current 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Fuse Amps 25 A (Power Circuit), 10 A (Signalling Circuit)
Max. Operating Watts 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e)
Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
Mechanical Durability 10 Mcycles
Rated Voltage 690V AC
Thermal Amperage 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Impulse Withstand Voltage 8 kV
IP Rating IP22
Rated Insulation Volts 600/690V
Overvoltage Category CAT III
Shock Resistance 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Rated Breaking Capacity 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Hold VA 4.5 VA
Watts Loss 1.3W
Tightening Torque 0.8 to 1.3 Nm
Environmental Attributes Mercury Free, Toxic Heavy Metal Free
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Switching Voltage 17 V (Signalling Circuit)
Mounts On Plate, Rail
Electrical Durability 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Switching Current 5 mA (Signalling Circuit)
Control Circuit Voltage Limits Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Operating Time 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Inrush VA 30 VA
Net Weight 0.18 kg
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Full Load Current - Resistive 20 A
Horsepower @ Single Phase - 120V AC 1/2 hp
Frequency 50/60 Hz
Horsepower @ Three Phase - 480V AC 7 1/2 hp
Horsepower @ Three Phase - 240V AC 3 hp
Electrical Operating Durability 1,300,000, 300,000
Mechanical Operating Durability 10,000,000
Includes Auxiliary Contacts Yes
Horsepower @ Single Phase - 240V AC 2 hp
Mounting Style DIN Rail, Plate
Embedded Surge Suppressor No
Contactor Style IEC
Reversing Capability Non-Reversing
Resistance Properties Insulation Resistant
Number of Normally Open Main Contacts 3
NEMA Enclosure Rating No Enclosure
Coil Voltage 230-240V AC
Terminal Connection Type Screw Clamp Terminals
Horsepower @ Three Phase - 600V AC 10 hp
Maximum Voltage Rating 690V AC
Number of Auxillary Contacts 1
Full Load Current - Inductive 12 A

Description

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 230-240V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.