Square D

Miniature IEC Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: No


original price: $111.99
new price: $110.99
/ea
Free Shipping & Returns

Free Shipping on orders over $50
Free 30-Day Returns

Key Features

  • Full Load Amps-Inductive 12 A
  • Action Non-Reversing
  • Full Load Amps-Resistive 20 A
  • Number of Poles 3
  • Reversing No
See all product information

Product Information

Dimensions

Height 1.77 in
Width 1.77 in
Depth 2.24 in
Working Height 6561.68 ft
Overall Height 2.28 in
Overall Width 1.77 in
Overall Depth 2.24 in

Details

Full Load Amps-Inductive 12 A
Item Miniature IEC Magnetic Contactor
Action Non-Reversing
Full Load Amps-Resistive 20 A
Number of Poles 3
Coil Volts 24 V DC
Reversing No
HP @ 1 Phase - 120V 1/2 hp
HP @ 1 Phase - 230V 1-1/2
HP @ 1 Phase - 240V 2 hp
HP @ 3 Phase - 240V 3 hp
HP @ 3 Phase - 575V 10 hp
Enclosure NEMA Rating No Enclosure
HP @ 3 Phase - 480V 7 1/2 hp
Aux. Contact Configuration 1NO
Hz 50/60
Auxiliary Contact Form 1NO
Standards CSA, UKCA, UL Listed
Frame / Series / Class / Code TeSys
Series TeSys K
Operating Speed 3600 cycles per hr
Impedance 3 mOhm
Net Weight 0.225 kg
Rated Making Capacity 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
Switching Current 5 mA (Signalling Circuit)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Control Circuit Voltage Limits Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
Application Motor Control, Resistive Load
Mounts On Plate, Rail
Electrical Durability 1.3 Mcycles 12 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 12 A AC-3e Less than or Equal to 440 V; 0.3 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 72 A AC-4 Less than or Equal to 440 V
Mechanical Durability 10 Mcycles
Overvoltage Category CAT III
Switching Voltage 17 V (Signalling Circuit)
Thermal Amperage 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Rated Breaking Capacity 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Impulse Withstand Voltage 8 kV
Rated Voltage 690V AC
Rated Insulation Volts 600/690V
Fuse Amps 25 A (Power Circuit), 10 A (Signalling Circuit)
Environmental Attributes Mercury Free, Toxic Heavy Metal Free
Operating Time 30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Tightening Torque 0.8 to 1.3 Nm
Maximum Voltage Rating 690V AC
Horsepower @ Three Phase - 480V AC 7 1/2 hp
Includes Auxiliary Contacts Yes
Full Load Current - Resistive 20 A
Number of Auxillary Contacts 1
Contactor Style IEC
Frequency 50/60 Hz
Full Load Current - Inductive 12 A
NEMA Enclosure Rating No Enclosure
Horsepower @ Three Phase - 600V AC 10 hp
Resistance Properties Insulation Resistant
Maximum Operating Temperature 122 Degrees F
Number of Normally Open Main Contacts 3
Embedded Surge Suppressor No
Mounting Style DIN Rail, Plate
Horsepower @ Three Phase - 240V AC 3 hp
Mechanical Operating Durability 10,000,000
Horsepower @ Single Phase - 240V AC 2 hp
Coil Voltage 24V DC
Reversing Capability Non-Reversing
Minimum Operating Temperature -13 Degrees F
Terminal Connection Type Screw Clamp Terminals
Horsepower @ Single Phase - 120V AC 1/2 hp
Contactor Application Resistive load; Motor control
IP Degree Of Protection IP2X
Ambient Air Temperature For Storage -58 to 176°F (-50 to 80°C)
Hold-In Power Consumption in W 3 W 68°F (20°C)
Power Pole Contact Composition 3 NO
Control Circuit Type DC standard
Average Impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
IRMS Rated Making Capacity 144 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Product Certifications CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Auxiliary Contacts Type Instantaneous 1 NO
Motor Power KW 3 kW 220 to 230 V AC 50/60 Hz AC-3; 5.5 kW 380 to 415 V AC 50/60 Hz AC-3; 5.5 kW 440 V AC 50/60 Hz AC-3; 4 kW 690 V AC 50/60 Hz AC-3; 3 kW 220 to 230 V AC 50/60 Hz AC-3e; 5.5 kW 380 to 415 V AC 50/60 Hz AC-3e; 5.5 kW 440 V AC 50/60 Hz AC-3e; 4 kW 690 V AC 50/60 Hz AC-3e; 3 kW 220 to 230 V AC 50/60 Hz AC-4; 5.5 kW 380 to 415 V AC 50/60 Hz AC-4; 5.5 kW 440 V AC 50/60 Hz AC-4
Flame Retardance V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Auxiliary Contact Composition 1 NO
Rated Operational Current 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Insulation Resistance Greater than 10 MOhm for signalling circuit
Maximum Operating Rate 3600 cyc/h
Conventional Free Air Thermal Current 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Connections - Terminals screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; Power circuit screw clamp terminals 2 0.00 in² (1.5 mm²)flexible with cable end
Poles Description 3P
Rated Operational Voltage Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Inrush Power in W 3 W 68°F (20°C))
Rated Insulation Voltage Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No 14
Heat Dissipation 1.3 W
Permissible Ambient Air Temperature Around The Device -40 to 158°F (-40 to 70°C) at Uc
Utilisation Category AC-3; AC-3e; AC-1; AC-4
Ambient Air Temperature For Operation -13 to 122°F (-25 to 50°C)
Operating Altitude 6561.68 ft (2000 m) without derating
Associated Fuse Rating 25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Short Time Withstand Current 115 A 122°F (50°C) - 1 s for power circuit; 105 A 122°F (50°C) - 5 s for power circuit; 100 A 122°F (50°C) - 10 s for power circuit; 75 A 122°F (50°C) - 30 s for power circuit; 55 A 122°F (50°C) - 1 min for power circuit; 50 A 122°F (50°C) - 3 min for power circuit; 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Minimum Switching Current 5 mA for signalling circuit
Mounting Support Plate; Rail
Product Or Component Type Contactor
Minimum Switching Voltage 17 V for signalling circuit

Description

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.