Molded Case Circuit Breaker, POWERPACT J Series, 200A, 3 Pole, 600V AC, 65kA at 240V AC

  • Mfr # JGA36200

  • Zoro # G0750531


product price:  $2,978.99
/ea
Free Shipping & Returns

Key Features

Series
POWERPACT J
Number of Poles
3
AC Voltage Rating
600V AC
Circuit Breaker Type
Standard
Phase
3
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
JGA36200
Zoro #
G0750531
UPC #
785901430735
Country of Origin
Mexico

Dimensions

Frame Size
250A/JG
Width
4.12 in
Depth
5 in
Height
7.52 in
Min. Wire Size
3 AWG
Max. Wire Size
350 MCM
Mounting Height
4.5 in (114.30 mm)
Power Wire Stripping Length
0.98 in (25 mm)

Details

Item
Molded Case Circuit Breaker
Series
POWERPACT J
Amps
200A
Number of Poles
3
AC Voltage Rating
600V AC
Circuit Breaker Type
Standard
Phase
3
Circuit Breaker Actuator
I-Line
Circuit Breaker Mounting Style
Plug In
Max. AIR Rating
65kA at 240V AC
Trip Type
Thermal Magnetic
Instantaneous Trip
Instantaneous
Terminal Connection
Lugs
Phase Connection
ABC
DC Voltage Rating
250/500V DC
For Use With
I Line Panelboards
High Amp Trip Setting
2,000 A
Standards
CCC, CE, CSA, IEC, UL Listed
Low Amp Trip Setting
1,000 A
Interrupt Rating
65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC
Features
Mercury Free; PVC Free
Application
HACR rated Applications; Distribution
Device Application
Distribution
Magnetic Tripping Current
2000 A
Ambient Air Temperature For Storage
-58 to 185°F (-50 to 85°C)
Suitability For Isolation
Yes IEC 60947-2
AWG Gauge
AWG 3/0 to 350 kcmil aluminium/copper terminals
Product Certifications
UL; CSA; NOM
Rated Impulse Withstand Voltage
8 kV IEC 60947-2
Circuit Breaker Application
HACR rated
Terminal Identifier
AL250JD
Network Frequency
50/60 Hz
Pollution Degree
3 IEC 60947-1
Long Time Pick-Up Adjustment Range
0.25 to 1 x In
Tightening Torque
221.27 lbf.in (25 N.m) 0.15 to 0.29 in² (95 to 185 mm²) (AWG 3/0 to 350 kcmil)
Rated Operational Voltage
600 V AC 50/60 Hz IEC 60947-3
Number Of Slots
2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)
Local Signalling
Switched off (OFF) 1 trip indicator green)
Ambient Air Temperature For Operation
28 to 158°F (-2 to 70°C)
IP Degree Of Protection
Front cover IP40
Breaking Capacity
65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489
Operating Altitude
Less than 6561.68 ft (2000 m) without derating; 5000 m with derating
Rated Service Breaking Capacity
65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2
Communication Interface
Modbus; Ethernet
Magnetic Hold Current
1000 A
Breaking Capacity Code
G
Rated Insulation Voltage
750 V IEC 60947-2
Quality Labels
CE
Continuous Current Rating
0.8
Protection Type
Overload protection; Short-circuit protection

Description

Molded Case Circuit Breaker, 200 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 25kA at 240V AC, For Use With I Line Panelboards, Series JG, High Amp Trip Setting 2,000 A, Low Amp Trip Setting 1,000 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating 500V DC, Terminal Connection Line/Load Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Instantaneous, Phase Connection ABC, Frame Size 250A/JG, Circuit Breaker Mounting Style I-Line, Height 11.48 in

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.