- Item
- Switch Kit
- Standards
- IEC 60947-3
- Mechanical Durability
- 30000 cycles
- Rotary Handle Padlocking
- 1 to 3 padlocks 4-8 mm
- Handle Colour
- red
- Breaking Capacity
- 1000 A 400 V AC-21A) || 1000 A 400 V AC-22A) || 1000 A 400 V AC-23A)
- Fire Resistance
- 960°C IEC 60695-2-1
- Contacts Type And Composition
- 3 NO
- Connections - Terminals
- power circuit screw clamp terminals 95-95 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible - with cable end
- Making Capacity
- 1250 A 400 V AC-21A || 1250 A 400 V AC-22A || 1250 A 400 V AC-23A
- Ambient Air Temperature For Operation
- -20-50°C
- Rotary Handle Mounting Style
- extended
- Electrical Durability
- 30000 cycles AC-21 || 30000 cycles DC-1 to 5
- Handle Front Plate Colour
- yellow
- [Ue] Rated Operational Voltage
- 690 V AC 50/60 Hz
- Fixing Mode
- by 4 screws handle || by clips switch || by screws switch
- Product Name
- TeSys VARIO
- [Ith] Conventional Free Air Thermal Current
- 125 A
- Poles Description
- 3P
- Performance Level
- high performance
- Mechanical Robustness
- vibrations 10 to 150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27
- Control Type
- rotary handle
- Tightening Torque
- power circuit 22.6-22.6 N.m screw clamp terminals
- Compatibility Code
- main switch disconnector
- Rated Operational Power In W
- 22 kW 230 to 240 V AC-3) || 30 kW 400 to 415 V AC-3) || 30 kW 690 V AC-3) || 37 kW 500 V AC-3) || 37 kW 690 V AC-23A) || 45 kW 500 V AC-23A) || 22 kW 230 to 240 V AC-23A) || 37 kW 400 to 415 V AC-23A)
- Mounting Support
- handle door || switch symmetrical rail || switch plate
- Device Short Name
- VCCF
- [Ie] Rated Operational Current
- 68.5 A AC-23 Ue: 400 V
- Intermittent Duty Class
- 30
- Range
- TeSys
- [Ithe] Conventional Enclosed Thermal Current
- 100 A
- Ip Degree Of Protection
- IP20 conforming to IEC 60529 || IP65
- Network Type
- DC || AC
- Rated Conditional Short-Circuit Current
- 10 kA 400 V 125 A aM || 10 kA 400 V 125 A gG
- [Icm] Rated Short-Circuit Making Capacity
- 2.8 kA 400 V at Ipeak
- Product Certifications
- CCC || UL || CSA || GL || UKCA
- [Icw] Rated Short-Time Withstand Current
- 1500 A 400 V 1 s
- Protective Treatment
- TC
- Product Or Component Type
- emergency stop switch disconnector
- Suitability For Isolation
- yes
- Device Composition
- handle || switch || shaft extension
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Marking
- 0 - 1
- Degree Of Protection
- IP20 conforming to IEC 60529; IP65
- Mounting Method
- By 4 screws handle; By clips switch; By screws switch
- IEC Terminal Connection
- Power circuit screw clamp terminals 0.15 in² (95 mm²) solid; Power circuit screw clamp terminals 0.11 in² (70 mm²) flexible - with cable end
- Rated Conditional Short Circuit Current
- 10 kA 400 V 125 A aM; 10 kA 400 V 125 A gG
- Iec Rated Operational Power in W
- 22 kW 230 to 240 V AC-3); 30 kW 400 to 415 V AC-3); 30 kW 690 V AC-3); 37 kW 500 V AC-3); 37 kW 690 V AC-23A); 45 kW 500 V AC-23A); 22 kW 230 to 240 V AC-23A); 37 kW 400 to 415 V AC-23A)