- MFR #
- 9038AG1N4
- Zoro #
- G3162975
- UPC #
- 785901183433
- Country of Origin
- Mexico
- Item
- Alternator Open Liquid Level Switch
- Switch Function
- Close On Rise
- Mounting
- Open Tank
- Float Travel
- 1 1/4 in
- NEMA Rating
- 1
- VA Rating
- 460V AC
- Operating Temp. Range
- -22 Degrees to 220 Degrees F
- Max. Current
- 600 A
- HP @ 1 Phase - 240V
- 3 hp
- Contact Form
- 4NC
- HP @ 1 Phase - 120V
- 2 hp
- HP @ 3 Phase - 240V
- 5 hp
- Body Material
- Steel
- Electrical Connections
- Screw Clamp
- Standards
- CE, CSA File No.LR25490, UL 508, UL E12158
- Max. Voltage
- 600
- Includes
- Two Level Non-Alternating - Does Not Include Float
- Amps
- 10 A
- Float Position
- Below
- Float Material
- Stainless Steel
- Features
- (4) Knock-Outs Conduit Entries for 1/2 in or 3/4 in
- Float Rod Angle
- Vertical
- Enclosure Material
- painted cold-rolled steel
- Product Type
- Alternator Open Liquid Level Switch
- Mounting Style
- Vertical
- Horsepower @ Single Phase - 240V AC
- 3 hp
- Electrical Connection
- Screw-Clamp Terminal
- Minimum Media Specific Gravity
- 0.85
- Horsepower @ Three Phase - 240V AC
- 5 hp
- NEMA Enclosure Rating
- 1
- Operating Temperature - Minimum
- -22 Degrees F
- Voltage Rating - Maximum
- 575 V AC
- Current Rating
- 600 A
- Operating Temperature - Maximum
- 220 Degrees F
- Horsepower @ Single Phase - 120V AC
- 2 hp
- Series
- 9038A
- Electrical Durability
- 100 cycles 60 cyc/mn
- Short-Circuit Protection
- 20 A cartridge fuse gG
- Device Application
- open tank
- Local Signalling
- without
- Contact Operation
- contacts close on liquid rise
- Float Movement
- variable adjustable
- Maximum Operating Rate
- 60 cyc/mn
- Controlled Fluid
- fresh water specific gravity of 0.85 in or higher || sea water specific gravity of 0.85 in or higher || hydraulic oil specific gravity of 0.85 in or higher || corrosive fluid specific gravity of 0.85 in or higher
- Electrical Circuit Type
- power circuit
- Product Destination
- for open tank
- Device Short Name
- 9038A
- Force Up To Trip
- 18 ozf at minimum adjustment || 16 ozf at maximum adjustment
- Ambient Air Temperature For Storage
- -22-220°F
- Product Or Component Type
- mechanical alternator
- Ambient Air Temperature For Operation
- -22-220°F
- Force Down To Trip
- 20 ozf at minimum adjustment || 17 ozf at maximum adjustment
- Nema Degree Of Protection
- NEMA 1 UL 50
- Terminal Block Type
- 8 terminals
- Product Specific Application
- mechanically alternating the operation of two pumps or motors
- Cable Entry Number
- 4 knock-outs for 1/2" or 3/4"conduit UL 508
- Terminals Description Iso N°1
- line-load-load-line
- Contacts Type And Composition
- 4 NC, snap action, DPST-DB, Form YY
- Motor Power Kw
- 1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.7 kW 5 hp)230 V AC, 3 phase || 0.75 kW 1 hp)460 V AC, 3 phase || 0.75 kW 1 hp)475 V AC, 3 phase || 0.18 kW 0.25 hp)32 V DC || 0.37 kW 0.5 hp)115 V DC || 0.37 kW 0.5 hp)230 V DC
- [Ui] Rated Insulation Voltage
- 575 V UL 508
- Operating Position
- vertical position only
- Device Mounting
- pedestal
- Mechanical Durability
- 300 cycles
- Factory Modification
- two-level non-alternating unit
- Product Certifications
- CSA file LR25490 || UL listed file E12158
- Kit Composition
- rod and float are to be choosen in accessories || float switch
- Current Rating - Maximum
- 600 A
- Switch Structure
- DPST