This item is Discontinued.

Tripp Lite UPS, SmartOnline, 2.2kVA, 1.6kW, SNMP, 2U, On-Line, Out: 120 V AC In: 120 V AC SU2200RTXL2UN

UPS, SmartOnline, 2.2kVA, 1.6kW, SNMP, 2U, On-Line, Out: 120 V AC In: 120 V AC (Discontinued)

  • Mfr # SU2200RTXL2UN
  • Zoro # G5175786
Get a 10% off coupon
Free 30-day returns Return Policy
Get 30 days to pay with Net 30 Apply Now
Unlock tax-exempt savings Add Tax Exemption

Specifications

Product Information

MFR #
SU2200RTXL2UN
Zoro #
G5175786
UPC #
037332181480
Country of Origin
China

Dimensions

Width
17.5"
Cord Length
10 ft
Depth
19"
Height
3.5"
Rack Height
2U
Primary UPS Width (mm)
445
UPS Input Cord Length (ft.)
10
Primary UPS Depth (mm)
483
Minimum Required Rack Depth with External Battery Pack (in.)
26
Minimum Required Rack Depth without External Battery Pack (in.)
24
UPS Power Module Dimensions (hwd, in.)
3.5 x 17.5 x 19
Primary UPS Height (mm)
89
UPS Input Cord Length Details
Built-in
Minimum Required Rack Depth (inches)
22

Details

Item
UPS,SmartOnline,2.2kVA,1.6kW,SNMP,2U
UPS Type
On-Line
Input Voltage
120 V AC
Output Voltage
120 V AC
Input Current
16 A
Transfer Time
No transfer time (0 ms.) in online, double-conversion mode
Battery Type
Valve Regulated Lead Acid (VRLA)
Rated input current (Maximum Load)
16A
Output Volt Amp Capacity (VA)
2200
Input Phase
Single-Phase
Severe Undervoltage Correction
2% output voltage regulation during undervoltages to 65 (under 70% load only)
EPO Port
RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems
Primary Form Factor
Rackmount
PowerAlert Software
For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Output Voltage Regulation (Economy Line Mode)
+/- 10%
Included Mounting Accessory Description
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Output kW Capacity (kW)
1.6
Undervoltage Correction
2% output voltage regulation during undervoltages to 80
Recommended Electrical Service
20A 120V
Battery Mode BTU / Hr. (Full Load)
889
Relative Humidity
0 to 95%, non-condensing
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
SNMP Compatibility
SNMP V1, V2c, V3
Power Factor
0.7
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Nominal Voltage Details
120V default
Communications Cable
Micro-USB, USB and DB9 cabling included
DC System Voltage (VDC)
48
Frequency Compatibility Details
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
Cooling Method
Fan
Audible Noise
< 45dB at 1m
AC Economy Mode Efficiency Rating (100% Load)
0.94
AC Mode BTU / Hr. (Full Load)
816
Switches
2 switches control off/on power status and alarm-cancel/self-test operation
External Battery Pack Compatibility
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
Output Voltage Regulation (Battery Mode)
+/- 2%
Communications Interface
Contact closure; DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; RJ45 Network; Slot for SNMP/Web interface; USB (HID enabled); USB-A; USB-B
AC Economy Mode BTU / Hr. (Full Load)
349
Half Load Runtime (min.)
14 min. (800w)
UPS Housing Material
Steel
Frequency Compatibility
50 / 60 Hz
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
Expandable Runtime Description
BP48V24-2U (limit 2 w/ 48VDCSPLITTER)
Low Voltage Transfer to Battery Power (Setpoint)
80V (100% load), 65V ( <70% load)
LED Indicators
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
Nominal Output Voltage(s) Supported
110V; 120V
Output Capacity Details
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Input Circuit Breakers
30A
Output Watt Capacity (Watts)
1600
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
UPS Dataline Suppression
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
Voltage Regulation Description
Online, double-conversion power conditioning
Output AC Waveform (Battery Mode)
Pure Sine wave
Nominal Input Voltage(s) Supported
110V AC; 120V AC
UPS AC Suppression Response Time
Instantaneous
Battery Access
Front panel battery access door
Expandable Runtime
Yes
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Installation Form Factors Supported with Included Accessories
4 post 19 inch rackmount
Crest Factor
0.125694444444444
Load Management Receptacles
Two switchable three-outlet 5-15/20R load banks
Full Load Runtime (min.)
4.5 min. (1600w)
Battery Replacement Description
Hot-swappable, user replaceable sealed, flame retardant, non-spillable batteries
Expandable Battery Runtime
Extended runtime supported via optional external battery packs
Network Monitoring Port Description
Includes pre-installed WEBCARDLX network interface; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR installed Network Management Card
EMI / RFI AC Noise Suppression
Yes
Overvoltage Correction
2% output voltage regulation during overvoltages to 150
High Availability UPS Features
Automatic inverter bypass; Hot swappable batteries
High Voltage Transfer to Battery Power (Setpoint)
150
UPS Input Connection Type
5-20P
Output Receptacles
(6) 5-15/20R; (1) L5-20R
UPS AC Suppression Joule Rating
570
Individually Controllable Load Banks
Yes
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Battery Recharge Rate (Included Batteries)
Less than 6 hours from 10% to 80% (typical, full load discharge)
Output Voltage Regulation (Line Mode)
+/- 2%
Output kVA Capacity (kVA)
2.2
Output AC Waveform (AC Mode)
Sine wave
Internal UPS Replacement Battery Cartridge
RBC94-2U
Installation Form Factors Supported with Optional Accessories
2 post rackmount (2POSTRMKITWM); 2-4 post front rail rackmount (UPSHDEARKIT); 4 post rackmount short-depth (4POSTRAILKITWM); Tower (2-9USTAND); Wallmount (2POSTRMKITWM)
Waveform Type
Sine Wave, Pure Sine Wave
Hot Swappable
Yes
Package Contents
SU2200RTXL2UN UPS with Pre-installed SNMPWEBCARD, Poweralert Software and Cabling, Mounting Hardware For 4 Post Rack Enclosures, Instruction Manual
Dataline Protection
RJ-11, RJ-45
Product Type
Double Conversion Online UPS
Surge Energy Rating
570 J
Receptacle Detail
6 x NEMA 5-15/20R, 1 x NEMA L5-20R
Maximum Operating Temperature
104°F (40°C)
Product Line
SmartOnline
Serial Port
Yes
Network Management
SNMP Manageable
USB
Yes
Software Included
Poweralert Software
Product Name
SU2200RTXL2UN UPS with Pre-installed SNMPWEBCARD
Protection Type
Over Voltage, Brownout, Under Voltage, EMI / RFI
Backup/Run Time (Half Load)
14 Minute
Typical Battery Recharge Time
6 Hour
Emergency Power OFF
Yes
Backup/Run Time (Full Load)
4.50 Minute
Certifications & Standards
UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Part 15 Category A (EMI)
Bypass Switch
Automatic
Plug/Connector Type
NEMA 5-20P
Sound Emission
45 dB
Thermal Dissipation
238.24 W
Status Indicators
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information, 4-LED meter displays load and battery charge levels, LED panel rotates for viewing in rack/tower formats
Form Factor
Rack/Tower
Alarm
Power Failure, UPS StartUp, UPS Fault, Overload, Remote Shutdown, Low Battery
Load Capacity
2200 VA/1600 W
Total Number of Expansion Slots
1
Circuit Breaker
Yes
Product Certifications
CSA (Canada); NOM (Mexico); UL 1778
Product Compliance
FCC Part 15 Class A (USA)
Runtime Full Load (min.)
4.5 min. (1600W)
Runtime Half Load (min.)
14 min. (800W)
Output Capacity (Watts)
1600
Network Management Cards
WEBCARDLX
UPS Applications
Mission Critical Applications
Output Capacity (VA)
2200
Package Includes
SU2200RTXL2UN UPS with Pre-installed Network Management Card interface;USB, DB9 and EPO cabling;Mounting hardware for 4 post rack enclosures;Instruction manual
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load
889

Description

UPS,SmartOnline,2.2kVA,1.6kW,SNMP,2U

Ratings & reviews

3 reasons you can count on us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.