Key Features
- UPS Type Line Interactive
- Power Rating 1.5 kVA
- Mounting Desktop/Tower
- Wattage 900 W
- Input Voltage 120V AC
Customers Also Purchased
- Brand Tripp Lite
- MFR # SMART1500SLT
- Zoro # G6214223
- UPC # 037332119896
- Country of Origin China
- Category Uninterruptible Power Supplies (UPS)
Dimensions
Height | 10 in |
Width | 7 in |
Depth | 13 in |
Cord Length | 6 ft |
UPS Power Module Dimensions (hwd, in.) | 10.2 x 6.8 x 13.2 |
Primary UPS Height (mm) | 259 |
UPS Input Cord Length (ft.) | 6 |
Primary UPS Width (mm) | 173 |
Primary UPS Depth (mm) | 335 |
Unit Dimensions (hwd / in.) | 10.250 x 6.750 x 13.250 |
Details
Item | UPS System |
UPS Type | Line Interactive |
Power Rating | 1.5 kVA |
Mounting | Desktop/Tower |
Wattage | 900 W |
Input Voltage | 120V AC |
Output Voltage | 100/110/120V AC |
Backup Time (Half/Full Load) | 20 min/8 min |
Outlet Type | UPS/Surge |
Medical Grade | No |
Number of Outlets | 8 |
Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
Special Features | Cold Start Operation Supported, Hot Swappable Batteries |
NEMA Plug Configuration | 5-15p |
Display Type | LED |
Phase | 1 |
Hz | 50/60 Hz |
NEMA Receptacle Configuration | 5-15R |
Ports | RS232, TEL/DSL, USB |
Transfer Time | 4 to 6 msec |
Standards | UL 1778 |
Automatic Volts Regulation | Yes |
Includes | erial Cables, PowerAlert Software CD-Rom, USB |
Footnotes | 4,6,8 |
Fax/Modem Line Protection | Yes |
Input Current | 8.6 A |
Green Certification or Other Recognition | UL1778 (USA), cUL (Canada), FCC Class B (emissions), IEC 1000-4-2 Level 3 (Electrostatic Discharge), IEC 1000-4-4 Level 2 (Fast Transient / Burst), IEC 1000-4-5 Level 3 (Lightning Surge), Conforms to IEEE 587 / ANSI C62.41 specifications |
Battery Type | Sealed Lead Acid (SLA) |
Capacity - Batteries | 1500 VA/900 W |
Input Connection | NEMA 5-15P Plug |
Frequency Compatibility | 50 / 60 Hz |
UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
Output AC Waveform (AC Mode) | Sine wave |
Battery Mode BTU / Hr. (Full Load) | 500 |
DC System Voltage (VDC) | 36 |
Audible Alarm | Audible alarm indicates power failure and overload conditions |
Output Voltage Regulation (Line Mode) | -13%, + 15% |
UPS Housing Material | Steel |
AC Mode Efficiency Rating (100% Load) | 0.95 |
Recommended Electrical Service | 15A 120V |
Output AC Waveform (Battery Mode) | Pure Sine wave |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Battery Recharge Rate (Included Batteries) | Less than 8 hours from 10% to 90% (typical, full load discharge) |
EMI / RFI AC Noise Suppression | Yes |
Input Phase | Single-Phase |
Output Receptacles | (8) 5-15R |
Internal UPS Replacement Battery Cartridge | RBC36-SLT |
Communications Interface | USB; DB9 Serial; Slot for SNMP/Web interface |
Expandable Runtime | No |
Low Voltage Transfer to Battery Power (Setpoint) | 95V (120V), 87V (110V), 83V (100V) |
Overvoltage Correction | Voltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 111 to 121 (100v) |
Network Management Cards | SNMPWEBCARD ; WEBCARDLX ; RELAYIOCARD |
Frequency Compatibility Details | Automatic frequency selection |
Nominal Input Voltage(s) Supported | 100V AC; 110V AC; 120V AC |
AC Mode BTU / Hr. (Full Load) | 148 |
Output Watt Capacity (Watts) | 900 |
Audible Noise | Audible Noise < 50 dBA at Front Side 1 Meter |
Nominal Output Voltage(s) Supported | 100V; 110V; 120V |
Cooling Method | Fan |
Primary Form Factor | Tower |
UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
UPS AC Suppression Response Time | Instantaneous |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection |
Individually Controllable Load Banks | No |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Communications Cable | USB and DB9 cabling included |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
Undervoltage Correction | Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v) |
High Voltage Transfer to Battery Power (Setpoint) | 145V (120V), 133V (110V), 121V (100V) |
Output Volt Amp Capacity (VA) | 1500 |
Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
UPS AC Suppression Joule Rating | 690 |
UPS Input Connection Type | 5-15P |
Output kVA Capacity (kVA) | 1.5 |
Battery Access | Battery access door |
Site Wiring Fault Indication | Rear panel site wiring fault LED |
Nominal Voltage Details | 120V default (voltage selection via back panel switches) |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Relative Humidity | 0 to 95%, non-condensing |
Rated input current (Maximum Load) | 10.1A (100V), 9.3A (110V), 8.6A (120V) |
High Availability UPS Features | Hot swappable batteries |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145 (120v), 87 to 133 (110v), 83 to 121 (100v) |
PowerAlert Software | For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
LED Indicators | Status LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
Form Factor | Tower |
USB | Yes |
Package Contents | SmartPro 1500SLT UPS, SMART 1500SLT UPS System, PowerAlert Software CD-Rom, USB and serial cabling, User manual with warranty information |
Plug/Connector Type | NEMA 5-15P |
Load Capacity | 1500 VA/900 W |
Hot Swappable | Yes |
Product Name | SmartPro 1500SLT UPS |
Product Line | SmartPro |
Battery Life | 6 Year |
Battery Chemistry | Lead Acid |
Typical Battery Recharge Time | 4 Hour |
Waveform Type | Sine Wave |
Total Number of Expansion Slots | 1 |
Alarm | On Battery, Overload |
Receptacle Detail | 8 x NEMA 5-15R |
Status Indicators | Includes 14 front panel LEDs to indicate line / battery power status, over / under voltage correction, battery charge level (4 LEDs), load percentage (4 LEDs), overload and replace battery. 1 rear panel site wiring fault indicator. |
Certifications & Standards | UL1778 (USA), cUL (Canada), FCC Class B (emissions), IEC 1000-4-2 Level 3 (Electrostatic Discharge), IEC 1000-4-4 Level 2 (Fast Transient / Burst), IEC 1000-4-5 Level 3 (Lightning Surge), Conforms to IEEE 587 / ANSI C62.41 specifications |
Network Management | SNMP Manageable |
Battery Mode Heat Dissipation (BTU/Hr) @ Full Load | 500 |
Package Includes | SMART1500SLT SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS;USB cable;DB9 cable;Owner's manual |
Installation Form Factors Supported with Included Accessories | Tower |
Operating Elevation (ft.) | 6561 ft. (2000 m) above sea level |
Power Factor | 0.63 |
UPS Applications | Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality |
Output Capacity Details | 7.5A @ 120V (default), 8.2A @ 110V, 9A @ 100V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds |
Output Capacity (VA) | 1500 |
Input Circuit Breakers | 15A |
Product Compliance | FCC Part 15 Class A (USA) |
Output Capacity (Watts) | 900 |
Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
Total Harmonic Distortion | 0.03 |
Description
UPS System, Line Interactive, Power Rating 1.5 kVA, Wattage 900 W, Input Voltage 120V AC, Output Voltage 100V AC, 110V AC, 120V AC, Backup Time (Half/Full Load) 20 min/8 min, Mounting Desktop/Tower, Outlet Type UPS/Surge, Number of Outlets 8, Medical Grade No, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes, Transfer Time 4 to 6 msec, Width 7 in, Depth 13 in, Height 10 in, Cord Length 6 ft, Display Type LED
Documents & Resources
- Hazardous material
3 Reasons You Can Count On Us
Supplies for every job.
10 million items and the exact one you need.
When you need it fast, count on Zoro!
2 million products ship in 1 day.
Stretch your budget further.
Everyday low prices on the brands you love.
Explore More Products
- KABLE KONTROL Kable Kontrol® 2:1 Polyolefin Heat Shrink Tubing - 3/8" Inside Diameter - 200' Length - Black (HS363-S200-BLACK)
- EATON BUSSMANN Midget Fuse, ECSR Series, Time-Delay, 30A, 600V AC, Non-indicating, 200kA (ECSR30)
- HUBBELL Single Pole Connector, Female, Blue (HBLFBBL)
- ABB Strap, Conduit, 3/8 In, Pk100 (HS 100 SC)
- TRIPP LITE UPS System, 2.2 kVA, 7 Outlets, Tower, Out: 100/110/120/127V AC , In:100/115/120/127V AC (SU2200XLCD)
- TRIPP LITE UPS System, 1.5 kVA, 8 Outlets, Desktop/Tower, Out: 120V AC , In:120V AC (SMART1500RMXL2UA)
- TRIPP LITE Smart UPS, 750 VA, 6 Outlets, Tower/Wall, Out: 115/120V AC , In:120V AC (SMART750USB)
- TRIPP LITE UPS System, 2.2 kVA, 4 Outlets, Desktop/Tower, Out: 120V AC , In:120V AC (SMART2200RM2U)
- TRIPP LITE Smart UPS, 3 kVA, 9 Outlets, Rack/Tower, Out: 120V AC , In:120V AC (SMART3000RM2U)
- TRIPP LITE UPS System, 550 VA, 8 Outlets, Desktop/Tower, Out: 115/120V AC , In:120V AC (INTERNET550U)
- EATON UPS System, Tower, Out: 120V AC , In:120V AC (5P1000)
- Tripp Lite Power Systems