Receptacle Configuration
5-15R
Footnotes
USB and TEL/DSL
Output Voltage
110 V, 115 V, 120 V
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
Fax/Modem Line Protection
Yes
NEMA Plug Configuration
5-15p
Input Voltage - UPS Systems
120V AC
Transfer Time
2 to 4 msec
Standards
CSA, CSA-C22.2 No. 107.3, FCC Part 15 Class B, NOM, RoHS, UL1778
Outlet Type - UPS Systems
UPS/Surge
NEMA Receptacle Configuration
5-15R
Automatic Volts Regulation
No
Medical Grade
Not Medical Grade Approved
VA Rating - UPS Systems
900.0 VA
Watts - UPS Systems
480.0 W
Mounting - UPS Systems
Desktop/Tower
Backup Time (Half/Full Load)
10 min/2.5 min
Mounting
Desktop, Tower, Wall
Special Features
Cold Start Operation Supported
Output Voltage - UPS Systems
115V AC, 120V AC
Green Certification or Other Recognition
Energy Star UL Listed Certification , ENERGY STAR 2.0
Capacity - Batteries
900 VA/480 W
Input Connection
NEMA 5-15P Plug
Storage Temperature Range
+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius
Input Circuit Breakers
10A
Output Voltage Regulation (Battery Mode)
120V (±10%)
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Low Voltage Transfer to Battery Power (Setpoint)
95
Installation Form Factors Supported with Included Accessories
Tower; Ultra-compact desktop; Wallmount
Operating Elevation (ft.)
Up to 10,000 ft.
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
Nominal Output Voltage(s) Supported
110V; 115V; 120V
Battery Recharge Rate (Included Batteries)
8 hours (10% to 90%)
Output Volt Amp Capacity (VA)
900
Half Load Runtime (min.)
7.8 min. (240w)
UPS Output Receptacles (Surge Suppression Only)
6 UPS outlets, 6 surge-only outlets
Communications Cable
USB interface cable included
Operating Elevation (m)
Up to 3000m
Nominal Voltage Details
120v nominal output in battery mode
High Voltage Transfer to Battery Power (Setpoint)
145
UPS AC Suppression Response Time
Instantaneous
Frequency Compatibility
50 / 60 Hz
Internal UPS Replacement Battery Cartridge
RBC51
LED Indicators
Set of 3 status LEDs indicate operating mode, low-battery, overload, replace-battery and fault conditions
UPS AC Suppression Joule Rating
316
Output AC Waveform (Battery Mode)
PWM sine wave
Communications Interface
USB (HID enabled)
Output Voltage Regulation (Line Mode)
120V (±20%)
Output Watt Capacity (Watts)
480
UPS Dataline Suppression
1 line TEL/DSL or Ethernet
Output Receptacles
(12) 5-15R
Full Load Runtime (min.)
1.7 min. (480w)
Output AC Waveform (AC Mode)
Pure sine wave
Individually Controllable Load Banks
No
High Availability UPS Features
Battery Independent Restart
EMI / RFI AC Noise Suppression
Yes
Nominal Input Voltage(s) Supported
120V AC
DC System Voltage (VDC)
12
Surge Energy Rating
316 J
Package Contents
Internet Office 900VA Mini Desktop UPS, INTERNET900U UPS system, USB cable, Owner's manual with warranty information
Certifications & Standards
Energy Star, UL Listed Certification
Dataline Protection
RJ-11
Load Capacity
900 VA/480 W
Receptacle Detail
6 x NEMA 5-15R
Typical Battery Recharge Time
4 Hour
Voltage Regulation Description
Input voltage range of 95 to 145
Output Capacity (Watts)
480
UPS Applications
Audio/Video; Retail/Point of Sale; Hospitality
Frequency Compatibility Details
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
Package Includes
INTERNET900U 900VA 480W 120V Standby UPS with 12 Outlets;USB cable;Owner's manual
Output Capacity Details
7.5A @ 120V. 110%±10%,GOES TO FAULT AFTER 5MIN; 120%±10%,GOES TO FAULT IMMEDIATELY 110%±10%,SHUTS DOWN IN 5 SEC; 120%±10%, SHUTS DOWN IMMEDIATELY
Run Time - Full Load
1.7 min
Operating Temperature - Maximum
104 Degrees F
Automatic Voltage Regulation
No Automatic Voltage Regulation
Surge Suppression Rating
316 J
Includes Battery
Battery Included
Replacement Battery Part Number
RBC51
Number of Outlets - Surge Only
6
Transfer Time - Minimum
6 msec
Battery Recharge Time
8 hr
Data Line Protection
Includes Data Line Surge Protection
Audible Alarm Conditions
Low Battery, Overload, Replace Battery
External Battery Compatible
Not External Battery Pack Compatible
Visible Indicator Light Conditions
Battery Low, Fault, Overload, Replace Battery
Transfer Time - Maximum
10 msec
Output Ports Included
USB
Number of Outlets - UPS
6
Run Time - Half Load
7.8 min
Operating Temperature - Minimum
32 Degrees F
Battery Chemistry
Valve Regulated Lead Acid
Manufacturer Warranty
3 yr Limited
Power Rating - Real
480 W
Input Current - Maximum
10 A
Power Rating - Apparent
900 VA