Straight Blade Receptacle, 5-20R, 20 A, 125V AC, 2 Pole, 3 Wire, Flush Mount, Grounded

  • Mfr # HBL8310

  • Zoro # G2250491


product price: $30.85
/ea

Key Features

Receptacle Type
Single
NEMA Receptacle Configuration
5-20R
Current Rating
20 A
Voltage Rating
125V AC
Phase
Single
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
HBL8310
Zoro #
G2250491
UPC #
783585015934
Country of Origin
United States

Dimensions

Width
1.63 in
Height
1.19 in
Overall Depth
1.2 in
Mount Hole Center-to-Center Height
3.3 in
Face Plate Width
1.6 in
Minimum Wire Size
12 AWG
Maximum Wire Size
10 AWG
Face Plate Height
1.9 in
Display Size
Standard Sized Product
Length
3.28 in
Dimensions
3.28 in x 1.63 in x 1.19 in
Wire Size
#12 AWG to #10 AWG

Details

Item
Straight Blade Receptacle
Receptacle Type
Single
NEMA Receptacle Configuration
5-20R
Current Rating
20 A
Voltage Rating
125V AC
Phase
Single
Number of Poles
2
Number of Wires
3
Wire Connection Type
Screw Terminals
Wiring Method
Back, Side
Grounding
Grounded
Housing Color
Brown
Mount Type
Flush
IP Rating
IP20
Standards
CSA Certified C22.2 No. 42 File 285, Federal Specification W-C-596, NEMA WD-6, UL 498 File E2186
Resistance Properties
Corrosion Resistant
Flange Type
Non-Flanged
Power Indicator
No
Tamper Resistant
No
Weather Resistant
No
Sub-Category
Single Receptacles
Material
Nylon
Weather Resistant - Plugs and Receptacles
No
Voltage
125VAC
Wiring Method - Plugs and Receptacles
Back and Side
Outlet Type
Single
Mounting Type - Plugs and Receptacles
Flush
Surge Suppression
No
Outlet Type - Plugs and Receptacles
Single
HP
1 hp
Mounting Type
Flush
Number of Gangs
1
Corrosion Resistant
No
NEMA Receptacle Configuration - Plugs and Receptacles
5-20R
Application Environment
Heavy Use Hospital Grade
Type
Single
NEMA Enclosure Rating
1
Housing Material
Nylon
For Location
Indoor
Includes
Grounding Clip, Mounting Hardware, Wall Plate or Weatherproof Cover
Horsepower Rating
1 hp
Connection Orientation
Straight
Surge Protection
No
Minimum Operating Temperature
-40 Degrees F
Polarized
Yes
Maximum Operating Temperature
167 Degrees F
Cover Type
No Cover
AFCI
No
UL 94 Flammability Rating
5VA, V-0, V-2
Grade
Hospital Grade Fed. Spec.
Shrouded
No
GFCI
No
Includes Mounting Hardware
Yes
Contact Material
Brass
Flammability
Top: UL 94V-2, Base: UL 94V-0 and UL 94-5 VA
Dielectric Voltage
Withstands 2,000V minimum
Terminal Identification
Terminals identified in accordance with UL 498 and CSA
Terminal Accommodation
#12-#10 AWG stranded or solid copper wire only
Device Color
Brown
Operating Temperatures
Maximum continuous 75°C; minimum -40°C (w/o impact)
Current Interrupting
Certified for current interrupting at full rated current
Poles and Wires
2 Pole, 3 Wire
Horsepower - Maximum
1
Application
Extra Heavy Duty Hospital Grade
Style
Finder Groove Face
Performance
Electrical - Current Interrupting - Certified for current interrupting at full rated current Electrical - Dielectric Voltage - Withstands 2,000V minimum Environmental - Flammability - Top: UL 94V-2, Base: UL 94V-0 and UL 94-5 VA Environmental - Operating Temperatures - Maximum continuous 75°C, minimum -40°C (w/o impact) Mechanical - Product Identification - Ratings are a permanent part of the device Mechanical - Terminal Accommodation - #12-#10 AWG stranded or solid copper wire only Mechanical - Terminal Identification - Terminals identified in accordance with UL 498 and CSA
Series
Hospital Grade
Wattage
2500 W
Material - Mounting Hardware
Screw Mounting
OEM Brand Name
Hubbell Wiring Device-Kellems
Environmental Conditions
Indoor Dry Unless Protected By Additional Means
Operating Temperature
Maximum continuous 75°C and minimum -40°C without Impact
Dielectric Strength
Withstands 2,000V minimum
Nema Rating
5-20R
Industry Standard(s)
Certified to CSA, C22.2, No. 42 File 285 Fed. Spec. W-C-596 NEMA® WD-6 Compliant UL Listed to UL498 File No. E2186

Description

HBL® Extra Heavy Duty Max Hospital Grade Devices - UL requirements for Hospital Grade devices is more stringent than those for standard devices. Hubbell receptacles are designed to meet and exceed the standards with Exclusive nickel-plated bypass contact design increases contact pressure, lowering the operating temperature; Four point grounding system provides redundant grounding for low resistance ground continuity in high abuse areas; Impact resistant deep face design prevents breakage. Because of these features and others, the benefit is performance, reliability and value for any health care facility.
• One-piece nickel-plated brass integral ground strap
• Patented bypass contact design

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.