- Item
- Electromechanical Timer
- Voltage
- 120V AC
- Operation Mode
- 7 Days
- Amps
- 40 A
- Time Minimum Setting
- 3.5 hr.
- Enclosure Type
- Steel
- Indoor/Outdoor Usage
- Indoor
- Min. Time Setting
- 3.5 hr
- Body Material
- Steel
- Max. Time Setting
- 21 hr
- Contact Form
- SPST
- Max. On/Off Cycles
- 3
- Contact HP @ 240V
- 5 hp
- Number of Poles
- 4
- Day Skipper
- Yes
- Nominal Max. Time Setting
- 7 day
- Description/Special Features
- Heavy-duty Clutchless Gears Prevent Slipping, Spring Wound Carry-Over
- Type
- 7-Day
- Contact HP @ 120V
- 2 hp
- NEMA Rating
- 1
- Time Setting Range
- 3-1/2 hr. to 21 hr.
- Extra Trippers
- 11Z966
- Number of Trippers Included
- 14
- Mount
- wall
- Standards
- cCSAus, cULus
- Product Type
- Timer
- Operating Temperature Min
- -40°C
- Motor Three Phase Load Ratings
- 7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz
- Number Of Circuits
- 4
- Has Manual Override CVL
- Yes
- Electronic Ballast Load Ratings
- 16 A, 277 VAC, 60 Hz
- Power Consumption Max W
- 3 W
- CSA Certification
- cCSAus
- Motor Single Phase Ranges
- 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
- Operating Temperature Max
- 130°C
- UL Cerfication File Number
- UL917
- Backup Type
- Spring Wound Carry-over
- Motor Three Phase Ranges
- 7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz
- Pilot Duty Load Ratings Ranges
- 1000 VA, 120-277 VAC, Per Pole, 60 Hz
- Market
- Commercial; Residential
- Inductive Load Ratings
- 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
- Resistive Load Ratings Ranges
- 40 A, 120-480 VAC, 60 Hz
- Input Voltage Ranges
- 120 VAC, 60 Hz
- Solutions
- Machinery & Pumps; Panel Integrators
- Maximum On Off Operations
- 28
- Wiring Option
- Terminals
- Tungsten Load Ratings
- 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
- Skipper Wheel Operation Mode
- Not Included
- Pilot Duty Load Ratings
- 1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz
- Electronic Ballast Load Ratings Ranges
- 16 A, 277 VAC, 60 Hz
- Motor Single Phase Load Ratings
- 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz
- Switch Type
- 4-PST/NO
- Applications
- Timing/Scheduling ON/OFF; Indoor Lighting Control
- Packaging Applications
- Heating; Air Conditioning; Pumps; Indoor/Outdoor Lighting; Motors; Signs; Filters; Fans
- Backup Protection Time
- 16 Hours
- Tungsten Load Ratings Ranges
- 40 A, 120-277 VAC, 60 Hz
- Backup Restoration Time
- 1 Hour for Every 2 Hours Without Power
- Inductive Load Ratings Ranges
- 40 A, 120-277 VAC, 60 Hz
- Application Compatibilities
- LED; HID
- UL Certification
- cULus
- Resistive Load Ratings
- 40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 480 VAC, 60 Hz
- Minimum On Off Time
- 3.5 hours
- Tungsten Range(s)
- 40 A, 120-277 VAC, 60 Hz
- Maximum Power Consumption (W)
- 3 W
- Minimum ON/OFF Times
- 3.5 hours
- Tungsten (NO)
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
- Skipper Wheel
- Not Included
- Has Manual Override
- Yes
- Electronic Ballast
- 16 A, 277 VAC, 60 Hz
- Resistive
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz
- Pilot Duty (NO)
- 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz
- Maximum ON/OFF Operations
- 28
- Features
- Carry-Over Automatically Rewinds When Power Resumes, Separate Clock Motor Terminals
- Inductive
- 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz
- Operating Temperature Max (°F)
- 130
- Input Voltage Range(s)
- 120 VAC, 60 Hz
- Operating Temperature Min (°F)
- -40
- Operating Temperature Max (°F)
- 130
- Operating Temperature Min (°F)
- -40
- On/Off Cycles - Maximum
- 28
- AC Voltage Rating
- 120V AC
- Mounting Style
- Surface
- Horsepower @ 240V - Maximum
- 5 hp
- Horsepower @ 120V - Maximum
- 2 hp
- Number of Trippers - Maximum
- 14
- Operating Temperature - Maximum
- 130 Degrees F
- Series
- T7000B
- Time Setting - Maximum
- 7 day
- NEMA Enclosure Rating
- 1
- Time Setting - Minimum
- 3.5 hr
- Compatible Lighting
- HID, LED
- Application
- Lighting
- Operating Temperature - Minimum
- -40 Degrees F
- Current Rating - Maximum
- 40 A
- Time Maximum Setting
- 7 days