IEC Magnetic Contactor, 1NC/1NO, 110V AC, 3 P, Reversing, Screw Clamp

  • Mfr # LC2D09F7

  • Zoro # G0849165


product price:  $305.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
110V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LC2D09F7
Zoro #
G0849165
UPC #
785901207375
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
86 mm
Overall Width
90 mm
Overall Height
77 mm

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
110V AC
Number of Poles
3
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
4
Standards
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, DNV, CSA, CCC, UL, GL, LROS, BV, RINA, GOST, UKCA, TH IEC 60068-2-30
Series
LC2D
HP @ 3 Phase - 575V
7 1/2 hp
Application
Motor Control, Resistive Load
Impedance
2.5 mOhm
Rated Breaking Capacity
250 A @ 440V
Rated Insulation Volts
600/690V
Switching Voltage
17 V (Signalling Circuit)
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50 Hz), 4 kW (at 380 to 400V AC 50 Hz), 4 kW (at 415 to 440V AC 50 Hz), 5.5 kW (at 500V AC 50 Hz), 5.5 kW (at 660 to 690V AC 50 Hz)
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Features
Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
Switching Current
5 mA (Signalling Circuit)
Tightening Torque
1.7 Nm (Control Circuit), 1.7 to 2.5 Nm (Power Circuit)
Impulse Withstand Voltage
6 kV
Overvoltage Category
CAT III
Inrush VA
70 VA
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Includes Protective Cover
Yes
Fuse Amps
25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Mechanical Durability
15 Mcycles
Signalling Circuit Frequency
25 to 400 Hz
Rated Short-Time Withstand Current
30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Non-Overlap Time
1.5 ms
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
IP Rating
IP20
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Fire Rating
UL 94 V1
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Electrical Durability
0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V)
Operating Speed
3600 cycles per hr
Watts Loss
2 to 3W
Net Weight
0.687 kg
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Horsepower @ Three Phase - 240V AC
2 hp
Full Load Current - Inductive
9:00 AM
Horsepower @ Three Phase - 480V AC
5 hp
Horsepower @ Three Phase - 208V AC
2 hp
Full Load Current - Resistive
25 A
Horsepower @ Single Phase - 240V AC
1 hp
Mounting Style
Plate, Rail
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)
Maximum Voltage Rating
690V AC, 300V DC

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, reversing unit rated for operation within IEC-standard specifications. It operates with a 110 V AC coil and features a 1NC/1NO auxiliary contact configuration. The contactor is part of the LC2D series, compatible with specified mounting options and wiring methods. It is rated for use with motor control and resistive loads within specified parameters and equipped with a protective cover meeting applicable standards.

Action: Reversing

  • Poles: 3
  • Coil Voltage: 110 V AC
  • Auxiliary Contact Form: 1NC/1NO
  • Application: Motor Control, Resistive Load
  • Electrical Connection: Screw Clamp Terminals
  • Mounting: Plate, Rail
  • Series: LC2D
  • Includes Protective Cover: Yes
  • IP Rating: IP20
  • Rated Voltage: 690 V AC, 300 V DC
  • Rated Making Capacity: 250 A @ 440 V (Power Circuit); 140 A (AC Signalling); 250 A (DC Signalling)
  • Full Load Current: Inductive 9 A; Resistive 25 A
  • Net Weight: 0.687 kg
  • Dimensions: Width 90 mm; Height 77 mm; Depth 86 mm
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.