Shop SCHNEIDER ELECTRIC

IEC Magnetic Contactor, 1NC/1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D09G7
  • Zoro # G0672454

product price: 
$
102.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
20 A
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
LC1D09G7
Zoro #
G0672454
UPC #
785901206958
Country of Origin
Indonesia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
20 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
7 1/2 hp
Enclosure NEMA Rating
No Enclosure
Frame / Series / Class / Code
TeSys
Reversing
No
Series
TeSys Deca
Mechanical Durability
15 Mcycles
Watts Loss
2 to 3W
Impedance
2.5 mOhm
Signalling Circuit Frequency
25 to 400 Hz
Rated Short-Time Withstand Current
105 A (at 40 Degrees C for 10 s Power Circuit), 210 A (at 40 Degrees C for 1 s Power Circuit), 30 A (at 40 Degrees C for 10 min Power Circuit), 61 A (at 40 Degrees C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impulse Withstand Voltage
6 kV
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Application
Motor Control, Resistive Load
Net Weight
0.32 kg
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Inrush VA
70 VA
Non-Overlap Time
1.5 ms
Includes Protective Cover
Yes
Switching Current
5 mA (Signalling Circuit)
Tightening Torque
1.7 Nm
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Fire Rating
UL 94 V1
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Overvoltage Category
CAT III
Rated Insulation Volts
600V, 690V
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Electrical Durability
0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V); 2 Mcycles (9 A, AC-3e, Less than 440 V)
IP Rating
IP20
Features
Without Built-In Suppressor Module
Fuse Amps
10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
Switching Voltage
17 V (Signalling Circuit)
Rated Breaking Capacity
250 A @ 440V
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Operating Speed
3600 cycles per hr
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Full Load Current - Resistive
20 A
Horsepower @ Three Phase - 208V AC
2 hp
Contactor Style
IEC
Horsepower @ Three Phase - 240V AC
2 hp
Phase
Three
Number of Normally Open Main Contacts
3
Electrical Operating Durability
2,000,000, 600,000
Resistance Properties
Fire Resistant, Insulation Resistant
Frequency
50/60 Hz
Horsepower @ Three Phase - 480V AC
5 hp
Full Load Current - Inductive
9 A
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 120V AC
1/3 hp
NEMA Enclosure Rating
No Enclosure
Mechanical Operating Durability
15,000,000
Maximum Voltage Rating
690V AC
Horsepower @ Single Phase - 240V AC
1 hp
Embedded Surge Suppressor
No
Horsepower @ Three Phase - 600V AC
7 1/2 hp
Minimum Operating Temperature
-40 Degrees F
Mounting Style
DIN Rail, Plate
Maximum Operating Temperature
140 Degrees F
Conventional Free Air Thermal Current
25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
3.03 in
Overall Width
1.77 in
Overall Depth
3.39 in

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing coil-operated switch rated for use in motor control and resistive load applications within specified parameters. It uses screw clamp terminals and features 1 normally open and 1 normally closed auxiliary contact (2 auxiliary contacts total). The unit is part of the TeSys Deca series, compatible with IEC-standard control panels, suitable for DIN rail or plate mounting as per specifications, and includes a protective cover; it does not include an enclosure or an embedded surge suppressor.

Poles: 3

  • Main contacts: 3 NO
  • Auxiliary contacts: 2 (1 NO / 1 NC)
  • Coil voltage: 120 V AC
  • Reversing: Non-Reversing
  • Series/Frame: TeSys Deca / TeSys
  • Mounting: DIN Rail, Plate
  • Electrical connection: Screw Clamp
  • Max voltage: 690 V AC; 300 V DC within specified limits
  • Frequency: 50/60 Hz
  • IP rating: IP20
  • Enclosure: No Enclosure
  • Protective cover: Yes
  • Standards: BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
  • Application: Intended for use in motor control and resistive load applications according to manufacturer specifications
  • Weight: 0.32 kg
  • Dimensions (approx.): Width 1.77 in, Height 3.03 in, Depth 3.38 in
  • Fire rating: UL 94 V1
  • Environmental traits: Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
  • Built-in suppressor: does not include a built-in surge suppression device; compatibility with external suppressors should be verified separately
  • Impulse withstand: rated for impulse withstand voltage of 6 kV under test conditions specified by standards
  • Hold/Inrush VA: Hold VA 7.5 VA; Inrush VA 70 VA
  • Operating speed/time: 3600 cycles per hr; 12–22 ms (Closing), 4–19 ms (Opening)
  • Mechanical durability: 15 Mcycles
  • Electrical durability: 2,000,000 (and 600,000) cycles indicated
  • Working temperature range: rated for operation within the specified temperature range of -40°F to 140°F (approx. -40°C to 60°C)
  • Shock/Vibration: tested according to applicable standards for shock and vibration levels; actual performance may vary based on application conditions
  • Auxiliary/Signalling: Includes Auxiliary Contacts; Signalling circuit frequency 25–400 Hz
  • Impedance: 2.5 mΩ
  • Rated making capacity: 250 A @ 440 V (Power Circuit), 140 A (AC Signalling), 250 A (DC Signalling)
  • Rated short-time withstand current: multiple values listed (e.g., 105–140 A depending on circuit)
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      13 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      4.5 million products ship in 1 day.

    • Stretch your budget further.

      Everyday low prices on the brands you love.