- MFR #
- LC2D25BD
- Zoro #
- G0895797
- UPC #
- 785901207603
- Country of Origin
- Indonesia
- Item
- IEC Magnetic Contactor
- Auxiliary Contact Form
- 1NC/1NO
- Coil Voltage
- 24V DC
- Number of Poles
- 3
- Full Load Amps-Inductive
- 25 A
- Full Load Amps-Resistive
- 40 A
- Reversing Capability
- Reversing
- Terminal Connection Type
- Screw Clamp
- Number of Auxillary Contacts
- 2
- Standards
- BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
- Includes
- Electrical Interlock
- Enclosure NEMA Rating
- No Enclosure
- HP @ 1 Phase - 230V
- 3
- Reversing
- Yes
- HP @ 3 Phase - 575V
- 20 hp
- Series
- TeSys Deca
- Tightening Torque
- 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
- Fire Rating
- UL 94 V1
- Operating Speed
- 3600 cycles per hr
- Switching Voltage
- 17 V (Signalling Circuit)
- Impedance
- 2 mOhm
- Shock Resistance
- 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
- Net Weight
- 1.117 kg
- Operating Time
- 53.55 to 72.45 ms (Closing), 16 to 24 ms (Opening)
- Fuse Amps
- 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
- Environmental Attributes
- Mercury Free, PVC Free, Pollution Degree 3
- Features
- Built-In Bi-Directional Peak Limiting Diode Suppressor; Preassembled with Reversing Power Busbar
- Impulse Withstand Voltage
- 6 kV
- IP Rating
- IP20
- Electrical Durability
- 1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V)
- Includes Protective Cover
- Yes
- Rated Insulation Volts
- 600/690V
- Application
- Motor Control, Resistive Load
- Control Circuit Voltage Limits
- Drop-Out DC: 0.1 to 0.25 Uc (at -40 to 70°C), Operational DC: 0.7 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
- Rated Short-Time Withstand Current
- 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
- Rated Breaking Capacity
- 450 A @ 440V
- Insulation Resistance Range
- Greater Than 10 MOhms (Signalling Circuit)
- Signalling Circuit Frequency
- 25 to 400 Hz
- Vibration Resistance
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Max. Operating Watts
- 5.5 kW (at 220 to 230V AC 50 Hz), 11 kW (at 380 to 400V AC 50 Hz), 11 kW (at 415 to 440V AC 50 Hz), 15 kW (at 500V AC 50 Hz), 15 kW (at 660 to 690V AC 50 Hz)
- Switching Current
- 5 mA (Signalling Circuit)
- Mechanical Durability
- 30 Mcycles
- Overvoltage Category
- CAT III
- Non-Overlap Time
- 1.5 ms
- Rated Making Capacity
- 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
- Frequency
- 50/60 Hz
- Horsepower @ Single Phase - 120V AC
- 2 hp
- Horsepower @ Three Phase - 240V AC
- 7 1/2 hp
- Embedded Surge Suppressor
- Yes
- Full Load Current - Inductive
- 25 A
- NEMA Enclosure Rating
- No Enclosure
- Horsepower @ Single Phase - 240V AC
- 3 hp
- Mechanical Operating Durability
- 30,000,000
- Electrical Operating Durability
- 1,400,000, 1,650,000
- Number of Normally Open Main Contacts
- 3
- Horsepower @ Three Phase - 480V AC
- 15 hp
- Full Load Current - Resistive
- 40 A
- Resistance Properties
- Fire Resistant, Insulation Resistant
- Maximum Voltage Rating
- 690V AC
- Maximum Operating Temperature
- 140 Degrees F
- Contactor Style
- IEC
- Horsepower @ Three Phase - 600V AC
- 20 hp
- Includes Auxiliary Contacts
- Yes
- Minimum Operating Temperature
- -40 Degrees F
- Horsepower @ Three Phase - 208V AC
- 5 hp
- Mounting Style
- DIN Rail, Plate
- Conventional Free Air Thermal Current
- 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)