Auxiliary Contact Form
1NC/1NO
Coil Voltage
230V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D25P7
Zoro #
G0850039
UPC #
785901686156
Country of Origin
Indonesia

Dimensions

Working Height
Up to 9842.52 ft
Overall Depth
3.62 in
Overall Width
1.77 in
Overall Height
3.35 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
230V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
Frame / Series / Class / Code
TeSys
Reversing
No
HP @ 3 Phase - 575V
20 hp
Series
TeSys Deca
Fuse Amps
10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit)
Features
Without Built-In Suppressor Module
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Switching Current
5 mA (Signalling Circuit)
Overvoltage Category
CAT III
Watts Loss
2 to 3W
Impedance
2 mOhm
Mechanical Durability
15 Mcycles
Includes Protective Cover
Yes
Rated Insulation Volts
600/690V
IP Rating
IP20
Rated Breaking Capacity
450 A @ 440V
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit)
Operating Speed
3600 cycles per hr
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Inrush VA
70 VA
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Rated Short-Time Withstand Current
240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Tightening Torque
1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Shock Resistance
8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Electrical Durability
1.65 Mcycles (25 A, AC-3, Less than 440 V); 1.4 Mcycles (40 A, AC-1, Less than 440 V); 1.65 Mcycles (25 A, AC-3e, Less than 440 V)
Switching Voltage
17 V (Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Impulse Withstand Voltage
6 kV
Non-Overlap Time
1.5 ms
Fire Rating
UL 94 V1
Max. Operating Watts
5.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 11 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 415 to 440V AC 50/60 Hz AC-3), 15 kW (at 500V AC 50/60 Hz AC-3), 15 kW (at 660 to 690V AC 50/60 Hz AC-3), 5.5 kW (at 400V AC 50/60 Hz AC-4), 5.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 11 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 415 to 440V AC 50/60 Hz AC-3e), 15 kW (at 500V AC 50/60 Hz AC-3e), 15 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Signalling Circuit Frequency
25 to 400 Hz
Net Weight
0.37 kg
Application
Motor Control, Resistive Load
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Single Phase - 120V AC
2 hp
Horsepower @ Three Phase - 208V AC
7 1/2 hp
Maximum Voltage Rating
690V AC
Embedded Surge Suppressor
No
Includes Auxiliary Contacts
Yes
Maximum Operating Temperature
140 Degrees F
Mechanical Operating Durability
15,000,000
Phase
Three
Horsepower @ Single Phase - 240V AC
3 hp
Horsepower @ Three Phase - 240V AC
7 1/2 hp
Number of Normally Open Main Contacts
3
Frequency
50/60 Hz
Full Load Current - Resistive
40 A
Minimum Operating Temperature
-40 Degrees F
Full Load Current - Inductive
25 A
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 600V AC
20 hp
Contactor Style
IEC
Horsepower @ Three Phase - 480V AC
15 hp
Mounting Style
DIN Rail, Plate
Electrical Operating Durability
1,400,000, 1,650,000
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit)

Description

The IEC Magnetic Contactor is a three-pole, non-reversing, electrically operated switch rated for use in motor control and resistive load applications.

It uses a 230 V AC coil with screw clamp terminals; includes 1NO/1NC auxiliary contacts (2 total); features a protective cover; conforms to IEC standards under the TeSys Deca family.

The device can be mounted on DIN rails or plates; it is supplied without an enclosed housing (IP20 rating).

Coil voltage: 230 V AC (50/60 Hz); Phase: Three

  • Poles and main contacts: 3 poles; rated for specified switching capacity within operational parameters
  • Auxiliary contacts: 2 contact points configured as normally open/normally closed as specified by manufacturer ratings
  • Connection method: Screw clamp terminals rated for appropriate wire sizes within installation guidelines
  • Mounting options: DIN rail or plate mounting according to standard practices
  • Series/frame designation: Based on manufacturer specifications
  • Enclosure/IP: Enclosure type varies depending on application requirements; IP20 rating indicates limited ingress protection when used with provided covers if applicable
  • Rated voltages: Based on product specifications but do not imply suitability beyond those ratings or guarantee performance at all conditions
  • Currents and making capacity: Current ratings specify maximum electrical loads per manufacturer data but do not guarantee operation under all circumstances or over time
  • Short-time withstand and surge: Short-time withstand capabilities are based on testing standards but do not ensure failure-free operation during actual use conditions outside tested parameters
  • Mechanical/electrical durability: Durability figures indicate typical cycle counts under test conditions but do not constitute guarantees of lifespan in specific environments or usage patterns
  • Operating times: 12–22 ms (Closing); 4–19 ms (Opening)
  • Hold/inrush power: Hold VA 7.5 VA (60 Hz, 20°C); 7 VA (50 Hz, 20°C); Inrush VA 70 VA
  • Protection and safety features: Embedded surge suppressor: No
  • Physical dimensions and weight: Width 1.77 in; Height 3.35 in; Depth 3.62 in; Net weight 0.37 kg
  • Environmental and standards: Standards include EN 60947-4-1, EN 60947-5-1, UL 508, UL Listed, and others; Shock: 8 G (Open), 15 G (Closed)
  • Reversing: Non-Reversing
  • Operating environment: Max ambient temperature 60°C (140°F)
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.