IEC Magnetic Contactor, 1NC/1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D80U7

  • Zoro # G2411656


product price:  $496.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
240V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D80U7
Zoro #
G2411656
UPC #
785901208037
Country of Origin
Czechia

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
5 in
Overall Width
3.35 in
Overall Depth
5.12 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
240V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
HP @ 3 Phase - 575V
60 hp
Frame / Series / Class / Code
TeSys
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
15
Reversing
No
Series
TeSys Deca
Signalling Circuit Frequency
25 to 400 Hz
Features
Without Built-In Suppressor Module
Mechanical Durability
4 Mcycles
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Operating Time
20 to 35 ms (Closing), 6 to 20 ms (Opening)
Includes Protective Cover
Yes
Shock Resistance
10 G for 11 ms (Contactor Closed), 8 G for 11 ms (Contactor Open)
Fuse Amps
10 A (Signalling Circuit), 200 A (Type 1 Power Circuit), 160 A (Type 2 Power Circuit)
Impulse Withstand Voltage
8 kV
Operating Speed
3600 cycles per hr
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Vibration Resistance
3 G (Contactor Closed), 2 G (Contactor Open)
Impedance
0.8 mOhm
Watts Loss
6 to 10W
Inrush VA
245 VA
Non-Overlap Time
1.5 ms
Application
Motor Control, Resistive Load
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Net Weight
1.59 kg
Max. Operating Watts
22 kW (at 220 to 230V AC 50/60 Hz AC-3), 37 kW (at 380 to 400V AC 50/60 Hz AC-3), 45 kW (at 415 to 440V AC 50/60 Hz AC-3), 55 kW (at 500V AC 50/60 Hz AC-3), 45 kW (at 660 to 690V AC 50/60 Hz AC-3), 15 kW (at 400V AC 50/60 Hz AC-4), 22 kW (at 220 to 230V AC 50/60 Hz AC-3e), 37 kW (at 380 to 400V AC 50/60 Hz AC-3e), 45 kW (at 415 to 440V AC 50/60 Hz AC-3e), 55 kW (at 500V AC 50/60 Hz AC-3e), 45 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Fire Rating
UL 94 V1
Electrical Durability
0.8 Mcycles (125 A, AC-1, Less than 440 V); 1.5 Mcycles (80 A, AC-3, Less than 440 V); 1.5 Mcycles (80 A, AC-3e, Less than 440 V)
Overvoltage Category
CAT III
Switching Current
5 mA (Signalling Circuit)
Rated Breaking Capacity
1100 A @ 440V
Rated Short-Time Withstand Current
640 A (at 40°C for 10 s Power Circuit), 990 A (at 40°C for 1 s Power Circuit), 135 A (at 40°C for 10 min Power Circuit), 320 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
IP Rating
IP20
Switching Voltage
17 V (Signalling Circuit)
Hold VA
26 VA
Control Circuit Voltage Limits
Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 0.8 to 1.1 Uc (at -40 to 55°C 50 Hz), 1 to 1.1 Uc (at 55 to 70°C 50/60 Hz); Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1100 A @ 440V (Power Circuit)
Embedded Surge Suppressor
No
Minimum Operating Temperature
-40 Degrees F
Number of Normally Open Main Contacts
3
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 240V AC
30 hp
Frequency
50/60 Hz
Maximum Voltage Rating
300V DC
Mechanical Operating Durability
4,000,000
Full Load Current - Inductive
80 A
Horsepower @ Single Phase - 240V AC
15 hp
Horsepower @ Three Phase - 480V AC
60 hp
Full Load Current - Resistive
125 A
Horsepower @ Single Phase - 120V AC
7 1/2 hp
Electrical Operating Durability
1,500,000, 800,000
Includes Auxiliary Contacts
Yes
Maximum Operating Temperature
140 Degrees F
Horsepower @ Three Phase - 208V AC
30 hp
Horsepower @ Three Phase - 600V AC
60 hp
Contactor Style
IEC
Resistance Properties
Fire Resistant, Insulation Resistant
Phase
Three
NEMA Enclosure Rating
No Enclosure
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 125 A (at 60°C Power Circuit)

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing electrical switch operated by a 240 V AC coil. It features 1 normally open and 1 normally closed auxiliary contact (2 total) and uses screw clamp terminals. The device is rated for operation with IEC-standard motor and resistive loads; it has an IP20 enclosure rating and the TeSys series designation; it can be mounted on DIN rail or plate. Main circuit ratings are specified as up to 690 V AC and 300 V DC; rated for operation at frequencies of 50/60 Hz.

Key features

  • Contactor type and action: IEC Magnetic Contactor, 3 poles, Non-Reversing; Auxiliary contacts: 1NO/1NC (2 total)
  • Coil and frequency: 240 V AC coil; 50/60 Hz operation
  • Enclosure and mounting: IP20 enclosure rating; Mounts on DIN rail or plate; Terminals: Screw Clamp
  • Main contacts and ratings: 3 normally open main contacts; Full Load Amps – Inductive: 80 A; Full Load Amps – Resistive: 125 A
  • Voltage ratings: Rated voltage: 690 V AC, 300 V DC
  • Durability and cycles: Electrical durability is specified as up to approximately 1,500,000 or 800,000 cycles under test conditions; Mechanical durability is approximately 4 million cycles
  • Time-related specs: Operating time – Closing: 20–35 ms; Opening: 6–20 ms; Non-overlap time: 1.5 ms
  • Inrush and hold: Inrush VA: 245 VA; Hold VA: 26 VA
  • Standards and series: Frame/Series: TeSys; Series: TeSys Deca; Standards include EN 60947-4-1, EN 60947-5-1; UL 508 listed; IEC standards including IEC 60947-4-1 and IEC 60947-5-1
  • Protective features and limits: Equipped with a protective cover (note: does not imply safety certification); Rated for ambient temperatures up to approximately 60°C; specific operational limits should be verified in detailed specifications. Shock and vibration ratings (e.g., 10 G closed, 8 G open; 3 G closed, 2 G open)
  • Physical dimensions and weight: Overall depth 5.12 in, height 5 in, width 3.34 in; Net weight 1.59 kg
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.