IEC Magnetic Contactor, 1NC/1NO, 480V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D50AT7

  • Zoro # G1756106


product price:  $284.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
480V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D50AT7
Zoro #
G1756106
UPC #
785901565291
Country of Origin
France

Dimensions

Working Height
Up to 9842.52 ft
Overall Width
2.17 in
Overall Depth
4.72 in
Overall Height
4.8 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
480V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
7-1/2
HP @ 3 Phase - 575V
40 hp
Reversing
No
Series
TeSys Deca
Includes
Everlink Power Connections
Operating Speed
3600 cycles per hr
Watts Loss
4 to 5W
Switching Voltage
17 V (Signalling Circuit)
Application
Motor Control, Resistive Load
Mechanical Durability
6 Mcycles
IP Rating
IP20
Max. Operating Watts
15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Electrical Durability
1.45 Mcycles (50 A, AC-3, Less than 440 V); 1.1 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
Fuse Amps
10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Impedance
1.5 mOhm
Rated Insulation Volts
600/690V
Operating Time
4 to 19 ms (Opening), 12 to 26 ms (Closing)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz) , Operational AC: 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 60 Hz)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Impulse Withstand Voltage
6 kV
Hold VA
13 VA
Net Weight
0.855 kg
Includes Protective Cover
Yes
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity
900 A @ 440V
Signalling Circuit Frequency
25 to 400 Hz
Inrush VA
140 VA
Features
Without Built-In Suppressor Module
Overvoltage Category
CAT III
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Rated Short-Time Withstand Current
400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Fire Rating
UL 94 V1
Switching Current
5 mA (Signalling Circuit)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Non-Overlap Time
1.5 ms
Horsepower @ Three Phase - 480V AC
40 hp
Minimum Operating Temperature
-40 Degrees F
Electrical Operating Durability
1,100,000, 1,450,000
Number of Normally Open Main Contacts
3
Maximum Operating Temperature
140 Degrees F
Embedded Surge Suppressor
No
Mechanical Operating Durability
6,000,000
Horsepower @ Single Phase - 240V AC
7 1/2 hp
Frequency
50/60 Hz
Full Load Current - Resistive
80 A
Horsepower @ Three Phase - 208V AC
15 hp
Horsepower @ Three Phase - 600V AC
40 hp
Phase
Three
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Single Phase - 120V AC
3 hp
Contactor Style
IEC
Mounting Style
DIN Rail, Plate
Includes Auxiliary Contacts
Yes
NEMA Enclosure Rating
No Enclosure
Full Load Current - Inductive
50 A
Maximum Voltage Rating
690V AC
Horsepower @ Three Phase - 240V AC
15 hp
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)

Description

Schneider Electric’s IEC Magnetic Contactor is a 3-pole, non-reversing, coil-driven switching device (IEC style) rated for controlling motor and resistive load circuits within specified parameters. It features 1 normally open and 1 normally closed auxiliary contact (2 auxiliary contacts total) and 3 normally open main contacts. The unit uses Screw Clamp Terminals for the control circuit and EverLink BTR screw connectors for the power circuit. It is part of the TeSys Deca series, compatible with DIN Rail or Plate mounting configurations; enclosure not included, and is rated for operation at 50/60 Hz within the specified voltage range up to 690V AC.

Key features

  • non-reversing action (no guarantee of specific operational behavior)
  • Poles/Main Contacts: 3 poles, 3 normally open main contacts
  • Auxiliary Contacts: 2 total (1NO/1NC)
  • Coil Voltage: 480 V AC; Hold VA: 13 VA
  • Frequency: 50/60 Hz
  • Maximum Voltage Rating: 690V AC
  • Full Load Amps: rated for full load currents up to these values under specified conditions
  • Series: TeSys Deca
  • Enclosure: No Enclosure; IP20
  • Mounting: DIN Rail, Plate; Mounts On: Plate, Rail
  • Dimensions: 4.72 in depth × 4.8 in height × 2.17 in width
  • Weight: 0.855 kg
  • Operating Times: typical operating times based on testing conditions, not guaranteed performance durations
  • Durability: expected durability based on testing standards, actual lifespan may vary
  • Short-Time Withstand: capable of handling short-duration current surges up to specified ratings under test conditions
  • Protection/Extras: Embedded Surge Suppressor: No; Protective Cover: Yes; Includes Everlink Power Connections
  • Fusing: 10 A (Signalling), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
  • Standards/ Certifications: EN 60947-4-1, EN 60947-5-1, UL 508, UL Listed, and others
  • Ratings & reviews

    3 reasons you can count on us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.