IEC Magnetic Contactor, 1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # DPE09BL

  • Zoro # G303481138


product price:  $32.19
/ea

Key Features

Auxiliary Contact Form
1NO
Coil Voltage
24V DC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
DPE09BL
Zoro #
G303481138
UPC #
-
Country of Origin
Indonesia

Dimensions

Overall Width
1.77 in
Overall Height
3.03 in
Working Height
Up to 6561.68 ft
Overall Depth
3.39 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
24V DC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
Enclosure NEMA Rating
3R; 4
HP @ 3 Phase - 575V
7 1/2 hp
Frame / Series / Class / Code
TeSys
Reversing
No
Special Features
Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
Features
Without Built-In Suppressor Module
Application
Motor Control, Resistive Load
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Control Circuit Voltage Limits
Drop-Out: 0.1 to 0.3 Uc (at 70°C); Operational: 0.8 to 1.25 Uc (at 60°C), 1 to 1.25 Uc (at 70°C)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Breaking Capacity
250 A @ 440V
Electrical Durability
0.6 Mcycles (20 A, AC-1, Less than 440 V); 1 Mcycles (9 A, AC-3, Less than 440 V)
Series
TeSys Easy
Rated Insulation Volts
600/690V
Fuse Amps
10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
Rated Making Capacity
250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Operating Time
65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
Non-Overlap Time
1.5 ms
Switching Current
5 mA (Signalling Circuit)
IP Rating
IP20
Overvoltage Category
CAT III
Signalling Circuit Frequency
25 to 400 Hz
Net Weight
0.32 kg
Impedance
2.5 mOhm
Impulse Withstand Voltage
6 kV
Shock Resistance
15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Operating Speed
3600 cycles per hr
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 400V AC 50/60 Hz), 4 kW (at 415 to 440V AC 50/60 Hz), 5.5 kW (at 500V AC 50/60 Hz), 5.5 kW (at 660 to 690V AC 50/60 Hz), 2.2 kW (at 400V AC 50/60 Hz)
Switching Voltage
17 V (Signalling Circuit)
Tightening Torque
1.7 Nm
Mechanical Durability
10 Mcycles
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Watts Loss
2 to 3W
Horsepower @ Single Phase - 240V AC
1 hp
Includes Auxiliary Contacts
Yes
Resistance Properties
Fire Resistant, Insulation Resistant
Horsepower @ Single Phase - 120V AC
1/3 hp
Horsepower @ Three Phase - 240V AC
2 hp
Horsepower @ Three Phase - 480V AC
3 hp
Horsepower @ Three Phase - 600V AC
7 1/2 hp
Contactor Style
IEC
Minimum Operating Temperature
-40 Degrees F
Embedded Surge Suppressor
No
Full Load Current - Resistive
9:00 AM
Maximum Operating Temperature
140 Degrees F
Maximum Voltage Rating
690V AC
Frequency
50/60 Hz
Full Load Current - Inductive
9:00 AM
Mechanical Operating Durability
10,000,000
Horsepower @ Three Phase - 208V AC
2 hp
Mounting Style
DIN Rail, Plate
Electrical Operating Durability
1,000,000, 600,000
Number of Normally Open Main Contacts
3
NEMA Enclosure Rating
No Enclosure
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 25 A (at 60°C Power Circuit)

Description

Schneider Electric IEC Magnetic Contactor, 3-pole, 24 V DC coil, non-reversing, 1 normally open auxiliary contact, mounted with screw clamp terminals. This IEC-style magnetic contactor is rated for operation within the specified voltage and current ranges in motor control and resistive load applications. It features a TeSys Easy frame and is suitable for installation in control panels with standard dimensions; complies with relevant standards.

Poles: 3; Main Contacts: 3 NO; Auxiliary Contacts: 1 NO; Coil Voltage: 24 V DC; Reversing: Non-Reversing

  • Frame: TeSys Easy; Control: 50/60 Hz; Electrical Connection: Screw Clamp Terminals
  • Mounting: DIN Rail, Plate; Mounts On: Plate, Rail; Enclosure: IP20; NEMA Rating: 3R; 4
  • Maximum Voltage: rated for operation up to 690 V AC / 300 V DC within specified conditions
  • Rated Voltage: rated for use at voltages up to these levels under specified conditions
  • Rated Making Capacity: 250 A @ 440 V (Power Circuit); 140 A (AC Signalling); 250 A (DC Signalling) → rated making capacity at specified voltages within the product's electrical ratings
  • Max. Operating Watts: 2.2 kW at 220–230 V AC; 4 kW at 380–400 V AC; 4 kW at 415–440 V AC; 5.5 kW at 500–690 V AC → capable of operating within the specified wattage ranges when used according to manufacturer instructions
  • Full Load Amps: Inductive 9 A; Resistive 9 A → rated for continuous operation at these current levels under normal conditions
  • Frequency: 50/60 Hz; Impedance: 2.5 mOhm
  • Impulse Withstand Voltage: 6 kV → withstands impulse voltages up to this level as per testing standards; does not imply safety guarantee during actual use; Includes Auxiliary Contacts: Yes; Non-Overlap Time: 1.5 ms
  • Operating Times (Closing/Opening): 65.45–88.55 ms / 20–30 ms → typical switching times based on design specifications; actual performance may vary depending on application conditions
  • Shock Resistance: 15 G (Closed); 10 G (Open); Vibration Resistance: 4 G (Closed); 2 G (Open) → tested resistance levels; does not imply immunity from damage or failure outside tested parameters
  • Thermal/Temperature: Max Operating Temperature 140 °F; Max Temperature 850 °C → rated for operation within these temperature ranges as per specifications; does not guarantee performance outside these limits
  • Rated Insulation Volts: 600/690 V; Special Features: Overvoltage Category III; Min Switching Voltage 17 V (Signalling Circuit); Insulation Resistance 10 MΩ (Signalling Circuit) → conforms to insulation ratings and categories defined by standards but does not guarantee protection against all electrical faults or failures
  • Electrical Durability: 1,000,000 cycles (overall); 0.6 Mcycles (20 A, AC-1, <440 V); 1 Mcycles (9 A, AC-3, <440 V)
  • Environments/Standards: Mercury Free; Toxic Heavy Metal Free; Pollution Degree 3; Standards: CSA, EN 60947-4-1, EN 60947-5-1, UL Listed, IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14
  • Weight: 0.32 kg; Depth: 3.39 in; Height: 3.03 in; Width: 1.77 in
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.