Schneider Electric

IEC Magnetic Contactor, 3 Poles, 240 V AC, 9 A, Reversing: No


product price: $118.99
/ea
Free Shipping & Returns

Free Shipping on orders over $50
Free 30-Day Returns

Key Features

  • Full Load Amps-Inductive 9 A
  • Full Load Amps-Resistive 20 A
  • Action Non-Reversing
  • Number of Poles 3
  • Reversing No
See all product information

Product Information

Dimensions

Height 3.03 in
Width 1.77 in
Depth 3.38 in
Working Height Up to 9842.52 ft
Overall Depth 3.39 in
Overall Height 3.03 in
Overall Width 1.77 in

Details

Item IEC Magnetic Contactor
Full Load Amps-Inductive 9 A
Full Load Amps-Resistive 20 A
Action Non-Reversing
Number of Poles 3
Coil Volts 240 V AC
Reversing No
HP @ 1 Phase - 230V 1
HP @ 1 Phase - 120V 1/2 hp
HP @ 1 Phase - 240V 1 hp
HP @ 3 Phase - 208V 2 hp
HP @ 3 Phase - 575V 7 1/2 hp
HP @ 3 Phase - 240V 2 hp
HP @ 3 Phase - 480V 5 hp
Enclosure NEMA Rating No Enclosure
Aux. Contact Configuration 1NO/1NC
Hz 50/60
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
Auxiliary Contact Form 1NO/1NC
Series TeSys Deca
Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Mechanical Durability 15 Mcycles
Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
Fuse Amps 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
Rated Insulation Volts 600/690V
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Electrical Durability 0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V); 2 Mcycles (9 A, AC-3e, Less than 440 V)
Rated Short-Time Withstand Current 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Overvoltage Category CAT III
Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Inrush VA 70 VA
Operating Speed 3600 cycles per hr
IP Rating IP20
Watts Loss 2 to 3W
Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Electrical Connection Screw Clamp Terminals
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Includes Protective Cover Yes
Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Max. Operating Watts 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
Signalling Circuit Frequency 25 to 400 Hz
Features Without Built-In Suppressor Module
Fire Rating UL 94 V1
Impulse Withstand Voltage 6 kV
Switching Current 5 mA (Signalling Circuit)
Max. Temperature 850°C
Rated Voltage 690V AC, 300V DC
Thermal Amperage 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
Switching Voltage 17 V (Signalling Circuit)
Mounts On Plate, Rail
Application Motor Control, Resistive Load
Impedance 2.5 mOhm
Net Weight 0.32 kg
Tightening Torque 1.7 Nm
Non-Overlap Time 1.5 ms
Rated Breaking Capacity 250 A @ 440V
Horsepower @ Single Phase - 240V AC 1 hp
Contactor Style IEC
Mechanical Operating Durability 15,000,000
Terminal Connection Type Screw Clamp Terminals
Horsepower @ Three Phase - 600V AC 7 1/2 hp
Embedded Surge Suppressor No
Horsepower @ Three Phase - 240V AC 2 hp
Coil Voltage 240V AC
Horsepower @ Single Phase - 120V AC 1/3 hp
Full Load Current - Resistive 20 A
Horsepower @ Three Phase - 480V AC 5 hp
Full Load Current - Inductive 9 A
Includes Auxiliary Contacts Yes
Electrical Operating Durability 2,000,000, 600,000
Number of Normally Open Main Contacts 3
Maximum Operating Temperature 140 Degrees F
Minimum Operating Temperature -40 Degrees F
Resistance Properties Fire Resistant, Insulation Resistant
Phase Three
Frequency 50/60 Hz
Number of Auxillary Contacts 2
Reversing Capability Non-Reversing
NEMA Enclosure Rating No Enclosure
Maximum Voltage Rating 690V AC
Horsepower @ Three Phase - 208V AC 2 hp
Mounting Style DIN Rail, Plate

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.