Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
Frame / Series / Class / Code
TeSys
HP @ 3 Phase - 575V
30 hp
Includes
Everlink Power Connections
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Rated Short-Time Withstand Current
320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Control Circuit Voltage Limits
Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C); Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Max. Operating Watts
18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Switching Current
5 mA (Signalling Circuit)
Switching Voltage
17 V (Signalling Circuit)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)
Application
Motor Control, Resistive Load
Rated Breaking Capacity
800 A @ 440V
Includes Protective Cover
Yes
Signalling Circuit Frequency
25 to 400 Hz
Overvoltage Category
CAT III
Impulse Withstand Voltage
6 kV
Operating Speed
3600 cycles per hr
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Operating Time
42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening)
Rated Insulation Volts
600/690V
Fuse Amps
10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
Mechanical Durability
10 Mcycles
Electrical Durability
0.7 Mcycles (60 A, AC-1, Less than 440 V); 1.5 Mcycles (40 A, AC-3, Less than 440 V); 1.5 Mcycles (40 A, AC-3e, Less than 440 V)
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Includes Auxiliary Contacts
Yes
Horsepower @ Single Phase - 120V AC
3 hp
Minimum Operating Temperature
-40 Degrees F
Embedded Surge Suppressor
Yes
Mechanical Operating Durability
10,000,000
Horsepower @ Three Phase - 480V AC
30 hp
Horsepower @ Three Phase - 208V AC
10 hp
Electrical Operating Durability
1,500,000, 700,000
Horsepower @ Three Phase - 240V AC
10 hp
Full Load Current - Inductive
40 A
Horsepower @ Three Phase - 600V AC
30 hp
Number of Normally Open Main Contacts
3
Horsepower @ Single Phase - 240V AC
5 hp
NEMA Enclosure Rating
No Enclosure
Maximum Operating Temperature
140 Degrees F
Mounting Style
DIN Rail, Plate
Maximum Voltage Rating
690V AC
Resistance Properties
Fire Resistant, Insulation Resistant
Full Load Current - Resistive
60 A
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit)