Key Features
- Full Load Amps-Inductive 25 A
- Full Load Amps-Resistive 40 A
- Number of Poles 4
- Coil Volts 120 V AC
- Reversing No
Customers Also Purchased
- Brand Schneider Electric
- MFR # LC1D258G7
- Zoro # G0478311
- UPC # 785901503149
- Country of Origin Multiple
- Category IEC Magnetic Contactors
Dimensions
Height | 4.13 in |
Width | 1.77 in |
Depth | 3.9 in |
Working Height | Up to 9842.52 ft |
Overall Width | 1.77 in |
Overall Height | 4.13 in |
Overall Depth | 3.9 in |
Details
Full Load Amps-Inductive | 25 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 40 A |
Number of Poles | 4 |
Coil Volts | 120 V AC |
Reversing | No |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Frame / Series / Class / Code | TeSys |
Standards | CB, CCC, CSA, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EAC, EN 60947-4-1, EN 60947-5-1, EU-RO-MR by DNV-GL, GB/T 14048.4, IEC 60947-4-1, IEC 60947-5-1, UKCA, UL 60947-5-1, UL Listed, UL 60947-4-1 |
Series | TeSys Deca |
Auxiliary Contact Form | 1NO/1NC |
Electrical Durability | 1.4 Mcycles (40 A, AC-1, Less than 440 V) |
Fire Rating | UL 94 V1 |
Rated Insulation Volts | 600/690V |
Application | Resistive Load |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 450 A @ 440V (Power Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 1.8 Nm (Power Circuit) |
Features | Without Built-In Suppressor Module |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Non-Overlap Time | 1.5 ms |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 40 A (at 60°C Power Circuit) |
IP Rating | IP20 |
Max. Temperature | 850°C |
Rated Breaking Capacity | 450 A @ 440V |
Electrical Connection | Screw Clamp Terminals |
Rated Short-Time Withstand Current | 240 A (at 40°C for 10 s Power Circuit), 380 A (at 40°C for 1 s Power Circuit), 50 A (at 40°C for 10 min Power Circuit), 120 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Impulse Withstand Voltage | 6 kV |
Impedance | 2 mOhm |
Switching Current | 5 mA (Signalling Circuit) |
Rated Voltage | 690V AC |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Operating Speed | 3600 cycles per hr |
Switching Voltage | 17 V (Signalling Circuit) |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 60°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 40 A (Type 2 Power Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Watts Loss | 2 to 3W |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Inrush VA | 70 VA |
Mechanical Durability | 15 Mcycles |
Overvoltage Category | CAT III |
Includes Protective Cover | Yes |
Net Weight | 0.425 kg |
Signalling Circuit Frequency | 25 to 400 Hz |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Mounts On | Plate, Rail |
Minimum Operating Temperature | -40 Degrees F |
Includes Auxiliary Contacts | Yes |
Full Load Current - Inductive | 25 A |
Number of Normally Open Main Contacts | 2 |
Resistance Properties | Fire Resistant, Insulation Resistant |
Mounting Style | DIN Rail, Plate |
Reversing Capability | Non-Reversing |
Terminal Connection Type | Screw Clamp Terminals |
Contactor Style | IEC |
NEMA Enclosure Rating | No Enclosure |
Number of Normally Closed Main Contacts | 2 |
Electrical Operating Durability | 1,400,000 |
Frequency | 50/60 Hz |
Maximum Voltage Rating | 690V AC |
Full Load Current - Resistive | 40 A |
Maximum Operating Temperature | 140 Degrees F |
Embedded Surge Suppressor | No |
Mechanical Operating Durability | 15,000,000 |
Coil Voltage | 120V AC |
Number of Auxillary Contacts | 2 |
Mounting Support | Rail; Plate |
Heat Dissipation | 2 to 3 W at 50/60 Hz |
Rated Insulation Voltage | Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL |
Protective Treatment | THIEC 60068-2-30 |
Connections - Terminals | Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 16 mm²) - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 16 mm²) - cable stiffness: solid without cable end |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Minimum Switching Current | 5 mA for signalling circuit |
Contact Compatibility | M6 |
Climatic Withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
Poles Description | 4P |
Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit |
Operating Altitude | 0 to 9842.52 ft (0 to 3000 m) |
Control Circuit Type | AC 50/60 Hz |
Minimum Switching Voltage | 17 V for signalling circuit |
Pollution Degree | 3 |
Average Impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Permissible Ambient Air Temperature Around The Device | -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating |
Flame Retardance | V1 conforming to UL 94 |
Conventional Free Air Thermal Current | 10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit |
Rated Operational Current | 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit |
Pole Contact Composition | 2 NO + 2 NC |
Power Dissipation Per Pole | 3.2 W AC-1 |
Inrush Power in VA | 70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C)) |
Hold-In Power Consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C)) |
IP Degree Of Protection | IP20 front face IEC 60529 |
Rated Short Time Withstand Current | 240 A 104°F (40°C) - 10 s for power circuit; 380 A 104°F (40°C) - 1 s for power circuit; 50 A 104°F (40°C) - 10 min for power circuit; 120 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
IRMS Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947 |
Compatibility Code | LC1D |
Product Or Component Type | Contactor |
Utilisation Category | AC-1; AC-3; AC-3e; AC-4 |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC 25 to 400 Hz |
Mechanical Robustness | Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms) |
Product Certifications | UL; CSA; CCC; EAC; UKCA; CB; EU-RO-MR by DNV-GL |
Control Circuit Voltage | 120 V AC 50/60 Hz |
Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Maximum Operating Rate | 3600 cyc/h 140°F (60°C) |
Protective Cover | With |
Fire Resistance | 1562°F (850°C) IEC 60695-2-1 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Description
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 4, Full Load Current - Inductive 25 A, Full Load Current - Resistive 40 A, Reversing Capability Non-Reversing, Overall Height 4.13 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC, Maximum Voltage Rating 690V AC
3 Reasons You Can Count On Us
-
Supplies for every job.
10 million items and the exact one you need.
-
When you need it fast, count on Zoro!
2 million products ship in 1 day.
-
Stretch your budget further.
Everyday low prices on the brands you love.
Explore More Products
- AC WORKS NEMA SS2-50R 50A 125/250V 4-Prong Locking Female Connector Assembly (AS-SS250R)
- SIEMENS Lamp Module w/Bulb, Green, LED, Plastic (3SU1401-1BF40-1AA0)
- IDEC 24V-Ac 24V-Dc Time Delay Relay (GT3F-2AD24)
- EATON Limit Switch, Plunger, Roller Lever, 1NC/1NO, 4A @ 400V AC, Actuator Location: Top (LS-S11S-LS)
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V DC, 65 A, Reversing: No (LC1D65ABD)
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 120 V AC, 80 A, Reversing: No (LC1D80G7)
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 4 Poles, 24 V AC, 40 A (LC1DT40B7)
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: No (LC1D12BL)
- SCHNEIDER ELECTRIC Miniature IEC Magnetic Contactor, 3 Poles, 110 V AC, 6 A, Reversing: No (LC1K0610F7)
- SCHNEIDER ELECTRIC IEC Magnetic Contactor, 3 Poles, 24 V AC, 65 A, Reversing: No (LC1D65AB7)
- SQUARE D IEC Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: No (LC1D09BD)
- Schneider Electric Contactors & Contacts