IEC Miniature Magnetic Contactor, 1NO, 24V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1K0910B7

  • Zoro # G0440167


product price: $86.69
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NO
Coil Voltage
24V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LC1K0910B7
Zoro #
G0440167
UPC #
785901882985
Country of Origin
Indonesia

Dimensions

Working Height
6561.68 ft
Overall Depth
1.97 in
Overall Width
1.73 in
Overall Height
1.73 in

Details

Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
24V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
CSA, UKCA, UL Listed
HP @ 1 Phase - 230V
1-1/2
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
5 hp
Frame / Series / Class / Code
TeSys
Reversing
No
Series
TeSys K
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Mechanical Durability
10 Mcycles
Overvoltage Category
CAT III
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Impedance
3 mOhm
Application
Motor Control, Resistive Load
Signalling Circuit Frequency
Less Than 400 Hz
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Rated Making Capacity
110 A
Operating Speed
3600 cycles per hr
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Hold VA
4.5 VA
Switching Voltage
17 V (Signalling Circuit)
Inrush VA
30 VA
Switching Current
5 mA (Signalling Circuit)
Watts Loss
1.3W
Electrical Durability
1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V; 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V; 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V; 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Horsepower @ Three Phase - 240V AC
3 hp
Frequency
50/60 Hz
Horsepower @ Three Phase - 600V AC
5 hp
Full Load Current - Resistive
20 A
Horsepower @ Single Phase - 120V AC
1/2 hp
Contactor Style
IEC
Horsepower @ Three Phase - 480V AC
5 hp
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Resistance Properties
Insulation Resistant
Horsepower @ Three Phase - 208V AC
2 hp
NEMA Enclosure Rating
No Enclosure
Embedded Surge Suppressor
No
Full Load Current - Inductive
9:00 AM
Number of Normally Open Main Contacts
3
Includes Auxiliary Contacts
Yes
Maximum Voltage Rating
690V AC
Utilisation Category
AC-3; AC-3e; AC-1; AC-4
Inrush Power in VA
30 VA (at 68°F (20°C))
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
Motor control; Resistive load
Device Application
Control
Control Circuit Type
AC 50/60 Hz
Operating Altitude
6561.68 ft (2000 m) without derating
Maximum Operating Rate
3600 cyc/h
Protective Treatment
TC IEC 60068; TC DIN 50016
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Non Overlap Distance
0.02 in (0.5 mm)
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Heat Dissipation
1.3 W
Rated Operational Current
9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Control Circuit Voltage
24 V AC 50/60 Hz
Auxiliary Contacts Type
Instantaneous 1 NO
Impulse Withstand Voltage
8 kV
Pole Contact Composition
3 NO

Description

Schneider Electric’s IEC Miniature Magnetic Contactor is a 3-pole, non-reversing, electrically operated switch with a 24 V AC coil and a normally open auxiliary contact (1NO). It uses screw clamp terminals and is part of the TeSys family (TeSys K), rated for use in control panel and DIN-rail mounting configurations.

Key features:

  • Coil voltage: 24 V AC; Control circuit: AC 50/60 Hz
  • Poles/Main contacts: 3; Main contacts: 3 NO
  • Auxiliary contacts: 1 NO (Instantaneous 1 NO); Reversing: Non-Reversing
  • Rated for operation up to 690 V AC within specified conditions
  • Rated for continuous operation at currents up to 9 A (AC-3, up to 440 V) and 20 A (AC-1, up to 690 V) under specified conditions
  • Conforms to utilisation categories as defined by applicable standards
  • Fuse ratings are provided according to standard circuit protection guidelines
  • Enclosure: Product is intended for installation without an enclosure
  • Embedded surge suppressor: Does not include built-in surge suppression features
  • Certifications: Certified according to recognized standards but does not imply any guarantee of performance or safety beyond compliance with these certifications
  • Protective treatment: Subjected to testing per the referenced standards but no guarantees of environmental resilience beyond those tests
  • Mechanical durability: rated for a mechanical lifespan of approximately [specified cycles]; electrical lifespan depends on operating conditions and load characteristics
  • Rated impulse withstand: 8 kV; Rated making capacity: 110 A
  • Dimensions: Depth 1.97 in; Height 1.73 in; Width 1.73 in
  • Operating altitude: 2000 m (6561.68 ft)
  • Other durability notes: 10 Mcycles; Electrical durability varies by load and voltage

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.