Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NC
Full Load Amps-Inductive
6 A
Full Load Amps-Resistive
15 A
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
HP @ 1 Phase - 230V
1-1/2
Enclosure NEMA Rating
No Enclosure
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Tightening Torque
0.8 to 1.3 Nm
Rated Insulation Volts
600/690V
Overvoltage Category
CAT III
Electrical Durability
1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
Impulse Withstand Voltage
8 kV
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Application
Motor Control
Mechanical Durability
5 Mcycles
Operating Speed
3600 cycles per hr
Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Switching Current
5 mA (Signalling Circuit)
Switching Voltage
17 V (Signalling Circuit)
Rated Making Capacity
110 A
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Features
Preassembled with Reversing Power Busbar
Signalling Circuit Frequency
Less Than 400 Hz
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Max. Operating Watts
1.5 kW (at 220 to 230V AC 50/60 Hz), 2.2 kW (at 380 to 415VAC 50/60 Hz), 3 kW (at 440V AC 50/60 Hz), 3 kW (at 480V AC 50/60 Hz), 3 kW (at 500 to 600V AC 50/60 Hz), 3 kW (at 660 to 690V AC 50/60 Hz)
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Horsepower @ Three Phase - 480V AC
3 hp
Electrical Operating Durability
1,300,000
Minimum Operating Temperature
-13 Degrees F
Horsepower @ Three Phase - 240V AC
1 1/2 hp
Horsepower @ Three Phase - 600V AC
3 hp
Full Load Current - Resistive
15 A
Maximum Operating Temperature
122 Degrees F
Horsepower @ Single Phase - 120V AC
1/2 hp
Embedded Surge Suppressor
No
Resistance Properties
Insulation Resistant
Full Load Current - Inductive
6:00 AM
Mechanical Operating Durability
5,000,000
Includes Auxiliary Contacts
Yes
Number of Normally Open Main Contacts
3
NEMA Enclosure Rating
No Enclosure
Maximum Voltage Rating
690V AC
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 208V AC
1 1/2 hp
Conventional Free Air Thermal Current
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)