- Item
- Rear Module Controller
- Port Type
- USB 2.0, USB-Mini B
- Voltage
- 24V DC
- For Use With
- HMIS85, Mfr. No. HMIS65
- Product Type
- Rear Module Controller
- Shock Resistance
- 147 m/s² 11 ms on DIN rail)IEC 60068-2-27 || 294 m/s² 6 ms on panel mounting)IEC 60068-2-27
- Overvoltage Protection
- with
- Discrete Input Current
- 7.83 mA fast input || 5 mA digital
- Ambient Air Temperature For Operation
- 0-50°C
- Downloadable Protocols
- Modbus || Modbus TCP/IP || CANopen
- Input Impedance
- 4.7 kOhm || 2.81 kOhm
- Environmental Characteristic
- corrosive gas free
- Maximum Output Frequency
- 100 kHz fast output (PTO mode) || 1 kHz fast output (PWM mode)
- Device Presentation
- basic element
- Input/Output Number
- 2 fast input FI0...FI1 || 14 digital input DI0...DI13 || 2 fast output FQ0...FQ1 || 8 digital output DQ0...DQ7
- Maximum Input Frequency
- 100 kHz fast input (encoder mode) A/B || 100 kHz fast input single phase || 100 kHz fast input pulse/direction
- Nema Degree Of Protection
- NEMA 4X front panel
- Software Designation
- SoMachine
- Product Certifications
- GOST || C-tick || KCC || cULus 508 || cULus CSA 22-2 No 142 || cUL 1604 Class 1 Division 2
- Memory Description
- flash NAND, 128 MB || internal data storage FRAM, 128 kB || application run DRAM, 128 MB
- Sensor Power Supply
- 15-28.8 V DC >= 15 V >= 5 mA <= 5 V <= 1.5 mA || 15-28.8 V DC >= 15 V >= 2.5 mA <= 5 V <= 1 mA
- Pollution Degree
- 2 IEC 60664
- Isolation Between Channels And Internal Logic
- 500 V DC
- Maximum Pressure
- 800...1114 hPa
- Discrete Input Number
- 2 fast input (normal mode) IEC 61131-2 Type 1 || 14 digital input IEC 61131-2 Type 1
- Ip Degree Of Protection
- IP20 IEC 60529 rear panel) || IP65 IEC 60529 front panel)
- Processor Frequency
- 333 MHz
- Connection Pitch
- 3.5 mm
- Operating System
- Harmony
- Configurable Filtering Time
- 0 ms no filter none) || 0.004...0.04 ms bounce filter latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) || 3...12 ms integrator none/run/stop)
- Immunity To Microbreaks
- 10 ms
- Number Of Pages
- limited by internal memory capacity
- Inrush Current
- 30 A
- Relative Humidity
- 5-85 % without condensation
- Standards
- FCC Class A || ANSI/ISA 12-12-01 || UL 508 || IEC 61000-6-2 || EN 61131-2 || CSA C22.2 No 213 Class I Division 2
- Discrete Output Voltage
- 24 V DC 19.2...28.8 V)transistor || 24 V DC 5...30 V)relay || 220 V AC 100...250 V)relay
- Storage Altitude
- 0-10000 m
- Local Signalling
- no indicator
- Ambient Air Temperature For Storage
- -20-60°C
- Marking
- CE
- Insulation Resistance
- > 10 MOhm between the I/O and internal logic || > 10 MOhm between power supply and earth
- Number Of Common Point
- 1 fast input (HSC mode) || 2 digital input
- Discrete Output Current
- 2 A 4 A)5 ms opening contact digital output || 2 A 4 A)2 ms closing contact digital output || 300 mA2 ms fast output (normal mode) || 50 mA2 ms fast output (PWM or PTO mode)
- Discrete Output Number
- 2 fast output (normal mode) source || 8 digital output source
- Realtime Clock
- built-in
- Operating Altitude
- <= 6561.68 ft (2000 m)
- Supply
- external source
- Maximum Cable Distance Between Devices
- shielded cable <10 m fast input || shielded cable <100 m digital input || unshielded cable <50 m digital input
- Power Consumption In W
- 15 W
- Vibration Resistance
- +/- 3.5 mm 5-9 Hz) IEC 60068-2-6 || 1 gn 9-150 Hz) IEC 60068-2-6
- Upgradeability
- Upgradeable through digital modules and upgraded components
- Rated Supply Voltage
- 24 V 20.4 to 28.8 V)DC
- Product Or Component Type
- controller
- Fixing Mode
- by 1 nut Ø 22 mm 1...6 mm thick panel
- Electromagnetic Compatibility
electrostatic discharge immunity test 8 kV air discharge) IEC 61000-4-2 || electrostatic discharge immunity test 6 kV contact discharge) IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz...3 GHz) IEC 61000-4-3 || electrical fast transient/burst immunity test 2 kV power lines) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV between analogue I/O and operating voltage) IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV relay wires) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV Ethernet line) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV COM line) IEC 61000-4-4 || electrical fast transient/burst immunity test 1 kV CAN line) IEC 61000-4-4 || surge immunity test 2 kV power supply (common mode)) IEC 61000-4-5 || surge immunity test 1 kV power supply (differential mode)) IEC 61000-4-5 || surge immunity test 1 kV common mode digital I/O) IEC 61000-4-5 || surge immunity test 0.5 kV differential mode digital I/O) IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) IEC 61000-4-6 || conducted emission 150 kHz...30 MHz EN 55011 || radiated emission 30 MHz...1 GHz EN 55011
- [Us] Rated Supply Voltage
- 24 V 20.4-28.8 V)DC
- Discrete Input Voltage
- 24 V DC sink or source (positive/negative)
- Enclosure Material
- PC/PBT
- Integrated Connection Type
- 1 serial link - RJ45 - RS232/RS485 <= 115.2 kbits/s) || 1 Ethernet TCP/IP - RJ45 || 1 USB 2.0 type mini B || 1 USB 2.0 type A || CANopen master bus - SUB-D 9
- Processor Name
- CPU RISC
- Absolute Accuracy Error
+/- 0.1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode) || 1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode) || +/- 5 % of full scale cyclic ratio 10...90% fast output (PWM or PTO mode) || +/- 10 % of full scale cyclic ratio 20...80% fast output (PWM or PTO mode) || +/- 15 % of full scale cyclic ratio 30...70% fast output (PWM or PTO mode)
- Features
- Built-In Real-Time Clock, Compact
- Communication Protocol
- CANopen, Modbus, Modbus TCP/IP
- Number of Inputs
- 16
- Output Type
- (2) Pulse Train Source Transistor, (8) Digital Output Source
- Number of Outputs
- 10
- Compatible with Manufacturer Model Number
- HMIS65, HMIS85
- Input Type
- (14) Digital, (2) High Speed Counter (HSC)
- Memory Type
- 128 KB FRAM, 128 Mb DRAM, 128 Mb Flash
- Compatible with Brand
- Schneider
- Compatible with Mfr. Model No.
- HMIS65, HMIS85
- For Use with Mfr Model Number
- HMIS65, HMIS85
- Compatible Manufacturer Part Number
- HMIS65, HMIS85
- Compatible Manufacturer Model Number
- HMIS65, HMIS85
- For Use With Mfr. Model Number
- HMIS65, HMIS85
- Compatible with Manufacturer Model No.
- HMIS65, HMIS85
- Compatible Pump Manufacturer Part Number
- HMIS65, HMIS85
- Compatible Mfr. Model Number
- HMIS65, HMIS85
- For Manufacturer Part Number
- HMIS65, HMIS85
- Compatible with Mfr. Model Number
- HMIS65, HMIS85