120VAC Non-Reversing Magnetic Contactor 3P 45A NEMA 2

  • Mfr # 8502SDG2V02S
  • Zoro # G1269222
product price: 
$
947.99
/ea
Free Shipping & Returns

Key Features

Action
Non-Reversing
Full Load Amps
45 A
Number of Poles
3
Coil Volts
120V AC
NEMA Contactor Size
2
See all product information
Unlock 30-day payment terms
Unlock 30-day payment terms
Business customers can apply for Net 30—no fees, no interest, fast approval. Terms apply.
Create Account
Get 10% off your order
Get 10% off your order
Sign up for our email list and receive your promo code via email.

Specifications

Details

MFR #
8502SDG2V02S
Zoro #
G1269222
UPC #
785901881407
Country of Origin
Korea, Republic of
Item
NEMA Magnetic Contactor
Action
Non-Reversing
Full Load Amps
45 A
Number of Poles
3
Coil Volts
120V AC
Reversing
No
HP @ 3 Phase - 208V
10 hp
HP @ 3 Phase - 240V
15 hp
HP @ 3 Phase - 575V
25 hp
Enclosure NEMA Rating
1
HP @ 3 Phase - 480V
25 hp
Standards
CSA, UL E78351 CCN NLDX
Hz
50/60 Hz
Frame / Series / Class / Code
Class 8502
Series
8502
Auxiliary Contact Form
Auxiliary Contacts Not Included
Product Or Component Type
contactor
Rated Power In Hp
10 HP 200 V AC || 15 HP 230 V AC || 25 HP 460 V AC || 25 HP 575 V AC
Product Compatibility
circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC || fuse J 100 A maximum, SCCR: 100 kA at 600 V AC || fuse T 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC
Poles Description
3P
Contactor Application
non-reversing
Phase
Three
Nema Degree Of Protection
NEMA 1 painted sheet steel
Control Type
no control units
Auxiliary Contact Composition
without
[Uc] Control Circuit Voltage
120 V AC 60 Hz || 110 V AC 50 Hz
[Ue] Rated Operational Voltage
600 V AC
Local Signalling
no indicator
Electrical Connection
screw clamp terminals
Control Circuit
separate control circuit
Line Rated Current
45 A
Product Certifications
UL listed file E78351 CCN NLDX || CSA
Frequency
50/60 Hz
NEMA Enclosure Material
Steel
Horsepower @ Three Phase - 600V AC
25 hp
Horsepower @ Three Phase - 480V AC
25 hp
Horsepower @ Three Phase - 240V AC
15 hp
Reversing Capability
Non-Reversing
Full Load Current - Inductive
45 A
Horsepower @ Single Phase - 240V AC
15 hp
NEMA Enclosure Rating
1
Includes Auxiliary Contacts
No
Maximum Voltage Rating
600V AC
Coil Voltage
120V AC
Horsepower @ Three Phase - 208V AC
10 hp
Embedded Surge Suppressor
No
Contactor Style
NEMA
Number of Auxillary Contacts
0
Terminal Connection Type
Screw Clamp Terminals
Certifications
UL listed file E78351 CCN NLDX; CSA
Horsepower Rating
10 HP 200 V AC; 15 HP 230 V AC; 25 HP 460 V AC; 25 HP 575 V AC
Short Circuit Current Rating
Circuit-breaker 100 A maximum, SCCR: 100 kA at 480 V AC; Fuse J 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse T 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK1 100 A maximum, SCCR: 100 kA at 600 V AC; Fuse RK5 100 A maximum, SCCR: 100 kA at 600 V AC

Dimensions

NEMA Contactor Size
2
Height
12.69 in
Width
6.03 in
Depth
7.81 in
NEMA Size
2
Overall Height
12.68 in
Overall Width
7.8 in
Overall Depth
6.02 in

Description

NEMA Magnetic Contactor, Auxiliary Contact Form Auxiliary Contacts Not Included, NEMA Enclosure Rating 1, NEMA Size 2, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 45 A, Reversing Capability Non-Reversing, Overall Height 12.68 in, Overall Width 7.8 in, Terminal Connection Type Screw Clamp Terminals, Series 8502, Number of Auxillary Contacts 0, Contactor Style NEMA, Horsepower @ Three Phase - 240V AC 15 hp, Horsepower @ Three Phase - 480V AC 25 hp, Phase Three

Ratings & reviews