Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Real support from real people
Contact our U.S. based team

Specifications

Product Information

MFR #
LC1D150G7
Zoro #
G1875325
UPC #
785901214519
Country of Origin
Czechia

Dimensions

Working Height
Up to 9842.52 ft
Overall Height
6.22 in
Overall Width
0.47 in
Overall Depth
5.35 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
120V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code
TeSys
Reversing
No
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
125 hp
Series
TeSys Deca
Rated Breaking Capacity
1400 A @ 440V
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Electrical Durability
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Inrush VA
280 to 350 VA
Hold VA
2 to 18 VA
IP Rating
IP20
Includes Protective Cover
Yes
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Mechanical Durability
8 Mcycles
Application
Motor Control, Resistive Load
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Impedance
0.6 mOhm
Impulse Withstand Voltage
8 kV
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Switching Voltage
17 V (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Operating Watts
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Switching Current
5 mA (Signalling Circuit)
Fire Rating
UL 94 V1
Overvoltage Category
CAT III
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Net Weight
2.5 kg
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Non-Overlap Time
1.5 ms
Signalling Circuit Frequency
25 to 400 Hz
Watts Loss
3 to 4.5W
Fuse Amps
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Operating Speed
1200 cycles per hr
Electrical Operating Durability
1,000,000, 850,000
Embedded Surge Suppressor
Yes
Horsepower @ Three Phase - 208V AC
40 hp
Maximum Operating Temperature
140 Degrees F
Frequency
50/60 Hz
Horsepower @ Single Phase - 240V AC
3 hp
Horsepower @ Three Phase - 240V AC
50 hp
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 480V AC
100 hp
Horsepower @ Three Phase - 600V AC
125 hp
Number of Normally Open Main Contacts
3
NEMA Enclosure Rating
No Enclosure
Maximum Voltage Rating
1000V AC
Full Load Current - Resistive
200 A
Mechanical Operating Durability
8,000,000
Full Load Current - Inductive
150 A
Minimum Operating Temperature
-40 Degrees F
Resistance Properties
Fire Resistant, Insulation Resistant
Phase
Three
Contactor Style
IEC
Includes Auxiliary Contacts
Yes
Rated Operational Current
200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Control Circuit Type
AC 50/60 Hz
Utilisation Category
AC-3; AC-1; AC-4; AC-3e
Inrush Power in VA
280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Climatic Withstand
IACS E10 exposure to damp heat
Rated Operational Voltage
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Pollution Degree
3
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Pole Contact Composition
3 NO
Contact Compatibility
M13
Safety Reliability Level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Voltage
120 V AC 50/60 Hz
Protective Treatment
THIEC 60068-2-30
Conventional Free Air Thermal Current
200 A (at 140°F (60°C)) for power circuit
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Contactor Application
Motor control; Resistive load
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Maximum Operating Rate
1200 cyc/h 140°F (60°C)
Compatibility Code
LC1D
Heat Dissipation
3 to 4.5 W at 50/60 Hz
Power Dissipation Per Pole
24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Protective Cover
With
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 120V AC, Number of Poles 3, Full Load Current - Inductive 150 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Ratings & Reviews

3 Reasons You Can Count On Us

  • Supplies for every job.

    Supplies for every job.

    10 million items and the exact one you need.

  • When you need it fast, count on Zoro!

    When you need it fast, count on Zoro!

    2 million products ship in 1 day.

  • Stretch your budget further.

    Stretch your budget further.

    Everyday low prices on the brands you love.