Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
125 hp
Enclosure NEMA Rating
No Enclosure
Signalling Circuit Frequency
25 to 400 Hz
Overvoltage Category
CAT III
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Max. Operating Watts
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Mechanical Durability
8 Mcycles
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Operating Speed
1200 cycles per hr
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Fuse Amps
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Switching Current
5 mA (Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Includes Protective Cover
Yes
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Impulse Withstand Voltage
8 kV
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
Rated Breaking Capacity
1400 A @ 440V
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Application
Motor Control, Resistive Load
Switching Voltage
17 V (Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Resistance Properties
Fire Resistant, Insulation Resistant
Embedded Surge Suppressor
Yes
Electrical Operating Durability
1,000,000, 850,000
Mechanical Operating Durability
8,000,000
Maximum Operating Temperature
140 Degrees F
Full Load Current - Inductive
150 A
Horsepower @ Three Phase - 480V AC
100 hp
Horsepower @ Three Phase - 240V AC
50 hp
Mounting Style
DIN Rail, Plate
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 208V AC
40 hp
Includes Auxiliary Contacts
Yes
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 600V AC
125 hp
Maximum Voltage Rating
1000V AC
Full Load Current - Resistive
200 A
Horsepower @ Single Phase - 240V AC
3 hp
NEMA Enclosure Rating
No Enclosure
Maximum Operating Rate
1200 cyc/h 140°F (60°C)
Control Circuit Voltage
208 V AC 50/60 Hz
Contactor Application
Resistive load; Motor control
Inrush Power in VA
280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Heat Dissipation
3 to 4.5 W at 50/60 Hz
Power Dissipation Per Pole
24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Rated Operational Current
200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Conventional Free Air Thermal Current
200 A (at 140°F (60°C)) for power circuit
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Rated Operational Voltage
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Pole Contact Composition
3 NO
Control Circuit Type
AC 50/60 Hz
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Safety Reliability Level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation Category
AC-1; AC-4; AC-3; AC-3e
Contact Compatibility
M13
Protective Treatment
THIEC 60068-2-30
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Climatic Withstand
IACS E10 exposure to damp heat
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating