IEC Magnetic Contactor, 1NC/1NO, 208V AC, 3 P, Non-Reversing, Screw Clamp

  • Mfr # LC1D150LE7

  • Zoro # G1543087


product price:  $836.99
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC/1NO
Coil Voltage
208V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC1D150LE7
Zoro #
G1543087
UPC #
785901640110
Country of Origin
Czechia

Dimensions

Working Height
Up to 9842.52 ft
Overall Width
0.47 in
Overall Height
6.22 in
Overall Depth
5.35 in

Details

Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
208V AC
Number of Poles
3
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 575V
125 hp
Enclosure NEMA Rating
No Enclosure
Reversing
No
Series
TeSys Deca
Signalling Circuit Frequency
25 to 400 Hz
Overvoltage Category
CAT III
Watts Loss
3 to 4.5W
Features
Built-In Bi-Directional Peak Limiting Diode Suppressor
Max. Operating Watts
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)
Mechanical Durability
8 Mcycles
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Operating Speed
1200 cycles per hr
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Fuse Amps
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Switching Current
5 mA (Signalling Circuit)
Hold VA
2 to 18 VA
Inrush VA
280 to 350 VA
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Includes Protective Cover
Yes
Net Weight
2.5 kg
Operating Time
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Fire Rating
UL 94 V1
Impulse Withstand Voltage
8 kV
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
IP Rating
IP20
Rated Breaking Capacity
1400 A @ 440V
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Application
Motor Control, Resistive Load
Switching Voltage
17 V (Signalling Circuit)
Impedance
0.6 mOhm
Non-Overlap Time
1.5 ms
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Resistance Properties
Fire Resistant, Insulation Resistant
Embedded Surge Suppressor
Yes
Phase
Three
Contactor Style
IEC
Electrical Operating Durability
1,000,000, 850,000
Mechanical Operating Durability
8,000,000
Frequency
50/60 Hz
Maximum Operating Temperature
140 Degrees F
Full Load Current - Inductive
150 A
Horsepower @ Three Phase - 480V AC
100 hp
Horsepower @ Three Phase - 240V AC
50 hp
Mounting Style
DIN Rail, Plate
Number of Normally Open Main Contacts
3
Horsepower @ Three Phase - 208V AC
40 hp
Includes Auxiliary Contacts
Yes
Minimum Operating Temperature
-40 Degrees F
Horsepower @ Three Phase - 600V AC
125 hp
Maximum Voltage Rating
1000V AC
Full Load Current - Resistive
200 A
Horsepower @ Single Phase - 240V AC
3 hp
NEMA Enclosure Rating
No Enclosure
Protective Cover
With
Maximum Operating Rate
1200 cyc/h 140°F (60°C)
Control Circuit Voltage
208 V AC 50/60 Hz
Contactor Application
Resistive load; Motor control
Inrush Power in VA
280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Pollution Degree
3
Heat Dissipation
3 to 4.5 W at 50/60 Hz
Power Dissipation Per Pole
24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Rated Operational Current
200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Conventional Free Air Thermal Current
200 A (at 140°F (60°C)) for power circuit
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Rated Operational Voltage
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Pole Contact Composition
3 NO
Control Circuit Type
AC 50/60 Hz
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Safety Reliability Level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Compatibility Code
LC1D
Utilisation Category
AC-1; AC-4; AC-3; AC-3e
Contact Compatibility
M13
Protective Treatment
THIEC 60068-2-30
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Climatic Withstand
IACS E10 exposure to damp heat
Ambient Air Temperature For Operation
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating

Description

The SQUARE D - IEC Magnetic Contactor is a non-reversing, three-pole contactor designed for motor control and resistive load applications. It operates with a coil voltage of 208V AC and features an auxiliary contact configuration of 1NO/1NC. The device has a built-in bidirectional peak limiting diode suppressor that operates within specified parameters. With an average impedance of 0.6 mOhm at Ith 200 A 50 Hz for the power circuit, it performs as per specifications under stated conditions.

Key Features:

  • Non-Reversing action suitable for motor control and resistive load applications.
  • Auxiliary Contacts Type: Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
  • Coil Technology: Built-in bidirectional peak limiting diode suppressor to manage voltage spikes.
  • Connections - Terminals: Screw clamp terminals compatible with varying cable stiffness types and sizes.
  • Electrical Durability: Rated for up to one million cycles at less than or equal to440 V (AC).
  • -Includes Protective Cover: Includes protective cover for use during operation.
  • -Mounting Style: Can be mounted on DIN Rail or Plate
  • -Rated Insulation Voltage: Power circuit rated at600 V CSA/UL; Signalling circuit rated at690 V IEC
  • -Rated Operational Current/Voltage : Up to200 A (at Less than140°F) at Less than or Equal to440 V AC AC- Rated Short-Time Withstand Current : Ranges from250 A (at40°Cfor10 min Power Circuit)to1400 A(at40°Cfor1 s Power Circuit)
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.