Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
30 hp
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Making Capacity
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Max. Operating Watts
7.5 kW (at 220 to 230V AC 50 Hz), 15 kW (at 380 to 400V AC 50 Hz), 15 kW (at 415 to 440V AC 50 Hz), 18.5 kW (at 500V AC 50 Hz), 18.5 kW (at 660 to 690V AC 50 Hz)
Operating Time
12 to 22 ms (Closing), 4 to 19 ms (Opening)
Mechanical Durability
15 Mcycles
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Features
Without Built-In Suppressor Module; Preassembled with Reversing Power Busbar
Overvoltage Category
CAT III
Electrical Durability
1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V)
Rated Insulation Volts
600/690V
Signalling Circuit Frequency
25 to 400 Hz
Tightening Torque
1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Hold VA
7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Breaking Capacity
550 A @ 440V
Rated Short-Time Withstand Current
60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Operating Speed
3600 cycles per hr
Fuse Amps
10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Switching Current
5 mA (Signalling Circuit)
Switching Voltage
17 V (Signalling Circuit)
Impulse Withstand Voltage
6 kV
Shock Resistance
8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Application
Motor Control, Resistive Load
Includes Protective Cover
Yes
Minimum Operating Temperature
-40 Degrees F
Mechanical Operating Durability
15,000,000
Number of Normally Open Main Contacts
3
Mounting Style
DIN Rail, Plate
Horsepower @ Single Phase - 240V AC
5 hp
NEMA Enclosure Rating
No Enclosure
Maximum Operating Temperature
140 Degrees F
Horsepower @ Three Phase - 480V AC
20 hp
Horsepower @ Three Phase - 600V AC
30 hp
Horsepower @ Single Phase - 120V AC
2 hp
Full Load Current - Inductive
32 A
Includes Auxiliary Contacts
Yes
Horsepower @ Three Phase - 240V AC
10 hp
Maximum Voltage Rating
690V AC
Horsepower @ Three Phase - 208V AC
7 1/2 hp
Resistance Properties
Fire Resistant, Insulation Resistant
Embedded Surge Suppressor
No
Full Load Current - Resistive
50 A
Electrical Operating Durability
1,400,000, 1,650,000
Conventional Free Air Thermal Current
10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)