Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Full Load Amps-Inductive
115 A
Full Load Amps-Resistive
200 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
HP @ 3 Phase - 240V
40 hp
HP @ 3 Phase - 575V
100 hp
Aux. Contact Configuration
1NO/1NC
HP @ 3 Phase - 480V
75 hp
HP @ 3 Phase - 208V
30 hp
Enclosure NEMA Rating
No Enclosure
Operating Time
6 to 20 ms (Opening), 20 to 50 ms (Closing)
Rated Breaking Capacity
1100 A @ 440V
Switching Current
5 mA (Signalling Circuit)
Max. Operating Watts
30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Rated Making Capacity
1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Includes Protective Cover
Yes
Shock Resistance
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Electrical Durability
0.8 Mcycles (200 A, AC-1, Less than 440 V); 0.95 Mcycles (115 A, AC-3, Less than 440 V); 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Thermal Amperage
200 A (at 60°C Power Circuit)
Fuse Amps
250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Rated Short-Time Withstand Current
250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impulse Withstand Voltage
8 kV
Application
Motor Control, Resistive Load
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Environmental Attributes
Mercury Free, PVC Free, Pollution Degree 3
Switching Voltage
17 V (Signalling Circuit)
Features
Without Built-In Suppressor Module
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Tightening Torque
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Rated Voltage
1000V AC, 300V DC
Electrical Connection
Screw Clamp Terminals
Control Circuit Voltage Limits
Operational AC: 0.85 to 1.1 Uc (at -40 to 55°C 60 Hz), 1 to 1.1 Uc (at 55 to 70°C 60 Hz); Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 60 Hz)
Mechanical Durability
8 Mcycles
Operating Speed
2400 cycles per hr
Signalling Circuit Frequency
25 to 400 Hz
Overvoltage Category
CAT III
Minimum Operating Temperature
-40 Degrees F
Electrical Operating Durability
800,000, 950,000
Horsepower @ Three Phase - 208V AC
30 hp
Includes Auxiliary Contacts
Yes
Resistance Properties
Fire Resistant, Insulation Resistant
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 600V AC
100 hp
Full Load Current - Resistive
200 A
Horsepower @ Three Phase - 240V AC
40 hp
Horsepower @ Three Phase - 480V AC
75 hp
Horsepower @ Single Phase - 240V AC
2 hp
Maximum Voltage Rating
1000V AC
Number of Normally Open Main Contacts
3
Maximum Operating Temperature
140 Degrees F
Full Load Current - Inductive
115 A
Embedded Surge Suppressor
No
NEMA Enclosure Rating
No Enclosure
Mechanical Operating Durability
8,000,000
Permissible Ambient Air Temperature Around The Device
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Rated Operational Voltage
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Rated Impulse Withstand Voltage
8 kV IEC 60947
IP Degree Of Protection
IP20 front face IEC 60529
Utilisation Category
AC-3; AC-1; AC-4; AC-3e
Power Dissipation Per Pole
24 W AC-1; 7.9 W AC-3; 7.9 W AC-3e
Heat Dissipation
3 to 8 W at 60 Hz
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Associated Fuse Rating
250 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 200 A gG at Less than or Equal to 690 V coordination type 2 for power circuit; 10 A gG for signalling circuit
Connections - Terminals
Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) - cable stiffness: solid without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) - cable stiffness: solid without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) - cable stiffness: solid without cable end
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Motor Power KW
30 kW at 220 to 230 V AC 50/60 Hz (AC-3); 55 kW at 380 to 400 V AC 50/60 Hz (AC-3); 59 kW at 415 to 440 V AC 50/60 Hz (AC-3); 75 kW at 500 V AC 50/60 Hz (AC-3); 80 kW at 660 to 690 V AC 50/60 Hz (AC-3); 65 kW at 1000 V AC 50/60 Hz (AC-3); 18.5 kW at 400 V AC 50/60 Hz (AC-4); 30 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 55 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 59 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 75 kW at 500 V AC 50/60 Hz (AC-3e); 80 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 65 kW at 1000 V AC 50/60 Hz (AC-3e)
Rated Insulation Voltage
Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Mounting Support
Rail; Plate
Maximum Operating Rate
2400 cyc/h 140°F (60°C)
Protective Treatment
THIEC 60068-2-30
Maximum Horse Power Rating
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Conventional Free Air Thermal Current
200 A (at 140°F (60°C)) for power circuit
Contactor Application
Motor control; Resistive load
Control Circuit Voltage
480 V AC 60 Hz
Hold-In Power Consumption in VA
22 VA 60 Hz cos phi 0.3 (at 68°F (20°C))
Rated Short Time Withstand Current
250 A 104°F (40°C) - 10 min for power circuit; 550 A 104°F (40°C) - 1 min for power circuit; 950 A 104°F (40°C) - 10 s for power circuit; 1100 A 104°F (40°C) - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Control Circuit Type
AC 60 Hz
IRMS Rated Making Capacity
1260 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Average Impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Pole Contact Composition
3 NO
Inrush Power in VA
300 VA 60 Hz cos phi 0.8 (at 68°F (20°C))
Contact Compatibility
M13
Product Or Component Type
Contactor
Minimum Switching Current
5 mA for signalling circuit
Flame Retardance
V1 conforming to UL 94
Mechanical Robustness
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Rated Operational Current
200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Minimum Switching Voltage
17 V for signalling circuit
Fire Resistance
1562°F (850°C) IEC 60695-2-1
Insulation Resistance
Greater than 10 MOhm for signalling circuit
Product Certifications
CSA; GOST; CCC; UL; RINA; BV; LROS (Lloyds register of shipping); DNV; GL; UKCA; CE