IEC Miniature Magnetic Contactor, 1NC, 240V AC, 3 P, Reversing, Screw Clamp

  • Mfr # LC2K1201U7

  • Zoro # G1336657


product price:  $198.90
/ea
Free Shipping & Returns

Key Features

Auxiliary Contact Form
1NC
Coil Voltage
240V AC
Number of Poles
3
Full Load Amps-Inductive
12 A
Full Load Amps-Resistive
20 A
See all product information
Get a 10% off coupon
Free 30-day returns
Return Policy
Get 30 days to pay with Net 30
Apply Now
Unlock tax-exempt savings
Add Tax Exemption

Specifications

Product Information

MFR #
LC2K1201U7
Zoro #
G1336657
UPC #
785901508366
Country of Origin
France

Dimensions

Height
3.54 in
Width
3.54 in
Depth
2.24 in
Overall Width
3.54 in
Overall Height
2.28 in
Overall Depth
2.24 in
Working Height
6561.68 ft

Details

Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NC
Coil Voltage
240V AC
Number of Poles
3
Full Load Amps-Inductive
12 A
Full Load Amps-Resistive
20 A
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
HP @ 1 Phase - 240V
1 1/2 hp
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
10 hp
Hz
50/60
HP @ 1 Phase - 230V
1-1/2
Aux. Contact Configuration
1NC
Action
Reversing
HP @ 3 Phase - 480V
7 1/2 hp
Reversing
Yes
HP @ 1 Phase - 120V
1/2 hp
HP @ 3 Phase - 240V
3 hp
Coil Volts
240 V AC
Series
TeSys K
IP Rating
IP20
Contactor Style
IEC
Number of Normally Open Main Contacts
3
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Maximum Voltage Rating
690V AC
Horsepower @ Single Phase - 120V AC
1/2 hp
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Resistance Properties
Insulation Resistant
Horsepower @ Three Phase - 240V AC
3 hp
Includes Auxiliary Contacts
Yes
Maximum Operating Temperature
122 Degrees F
Electrical Operating Durability
1,300,000, 300,000
Full Load Current - Resistive
20 A
Mechanical Operating Durability
5,000,000
Embedded Surge Suppressor
No
NEMA Enclosure Rating
No Enclosure
Full Load Current - Inductive
12 A
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 600V AC
10 hp
Minimum Operating Temperature
-13 Degrees F
Frequency
50/60 Hz
Mounting Support
Rail; Plate
Control Circuit Type
AC 50/60 Hz
Watts Loss
1.3W
Associated Fuse Rating
25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Hold VA
4.5 VA
Overvoltage Category
CAT III
Signalling Circuit Frequency
Less Than 400 Hz
Connections - Terminals
screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end
Flame Retardance
V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Minimum Switching Current
5 mA for signalling circuit
Control Circuit Voltage
230 to 240 V AC 50/60 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage
17 V for signalling circuit
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Electrical Durability
0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Operating Speed
3600 cycles per hr
Rated Operational Current
12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Motor Power KW
3 kW 220 to 230 V AC 50/60 Hz; 5.5 kW 380 to 415 V AC 50/60 Hz; 5.5 kW 440 V AC 50/60 Hz; 4 kW 690 V AC 50/60 Hz
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque
0.8 to 1.3 Nm
Rated Insulation Volts
600/690V
Rated Voltage
690V AC
IP Degree Of Protection
IP20 VDE 0106
Rated Insulation Voltage
Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No 14
Features
Preassembled with Reversing Power Busbar
Device Application
Control
Switching Current
5 mA (Signalling Circuit)
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Hold-In Power Consumption in VA
4.5 VA (at 68°F (20°C))
Rated Making Capacity
144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Electrical Connection
Screw Clamp Terminals
Inrush Power in VA
30 VA (at 68°F (20°C))
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Maximum Operating Rate
3600 cyc/h
Heat Dissipation
1.3 W
Rated Operational Voltage
Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
IRMS Rated Making Capacity
144 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated Short-Time Withstand Current
115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Thermal Amperage
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Max. Operating Watts
4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Impulse Withstand Voltage
8 kV
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Mounts On
Plate, Rail
Protective Treatment
TC IEC 60068; TC DIN 50016
Net Weight
0.39 kg
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Power Pole Contact Composition
3 NO
Ambient Air Temperature For Operation
-13 to 122°F (-25 to 50°C)
Impedance
3 mOhm
Auxiliary Contacts Type
Instantaneous 1 NC
Operating Altitude
6561.68 ft (2000 m) without derating
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Control Circuit Voltage Limits
Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Product Or Component Type
Reversing contactor
Utilisation Category
AC-3; AC-3e; AC-4; AC-1
Ambient Air Temperature For Storage
-58 to 176°F (-50 to 80°C)
Inrush VA
30 VA
Rated Breaking Capacity
110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Product Certifications
CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Rated Short Time Withstand Current
115 A 122°F (50°C) - 1 s for power circuit; 105 A 122°F (50°C) - 5 s for power circuit; 100 A 122°F (50°C) - 10 s for power circuit; 75 A 122°F (50°C) - 30 s for power circuit; 55 A 122°F (50°C) - 1 min for power circuit; 50 A 122°F (50°C) - 3 min for power circuit; 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Interlocking Type
Mechanical
Mechanical Durability
5 Mcycles
Application
Motor Control, Resistive Load
Non Overlap Distance
0.02 in (0.5 mm)
Poles Description
3P
Contactor Application
Motor control; Resistive load
Switching Voltage
17 V (Signalling Circuit)
Insulation Resistance
Greater than 10 MOhm for signalling circuit

Description

The SQUARE D IEC Miniature Magnetic Contactor is a compact, electrically operated switch used to control low-power circuits. It is a 3-pole, reversing contactor with a 240 V AC coil and a single 1NC auxiliary contact, rated for operation within the specified load types. The unit uses screw clamp terminals and can be mounted on DIN rail or plate in space-constrained control panels.

Action: Reversing

  • Coil voltage: 240 V AC
  • Poles: 3P
  • Main contacts: 3 NO
  • Auxiliary contact: Instantaneous 1 NC (1NC)
  • Terminals: Screw Clamp
  • Mounting: DIN Rail; Plate
  • Enclosure/IP: No Enclosure; IP20
  • Series: TeSys K
  • Frequency: 50/60 Hz
  • Ambient operating temperature: -25 to 50 °C
  • Ambient storage temperature: -50 to 80 °C
  • Net weight: 0.39 kg
  • Ratings & Reviews

    3 Reasons You Can Count On Us

    • Supplies for every job.

      Supplies for every job.

      10 million items and the exact one you need.

    • When you need it fast, count on Zoro!

      When you need it fast, count on Zoro!

      2 million products ship in 1 day.

    • Stretch your budget further.

      Stretch your budget further.

      Everyday low prices on the brands you love.