Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NC
Full Load Amps-Inductive
12 A
Full Load Amps-Resistive
20 A
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
HP @ 1 Phase - 240V
1 1/2 hp
Enclosure NEMA Rating
No Enclosure
HP @ 3 Phase - 575V
10 hp
HP @ 1 Phase - 230V
1-1/2
Aux. Contact Configuration
1NC
HP @ 3 Phase - 480V
7 1/2 hp
HP @ 1 Phase - 120V
1/2 hp
Number of Normally Open Main Contacts
3
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Maximum Voltage Rating
690V AC
Horsepower @ Single Phase - 120V AC
1/2 hp
Horsepower @ Three Phase - 480V AC
7 1/2 hp
Resistance Properties
Insulation Resistant
Horsepower @ Three Phase - 240V AC
3 hp
Includes Auxiliary Contacts
Yes
Maximum Operating Temperature
122 Degrees F
Electrical Operating Durability
1,300,000, 300,000
Full Load Current - Resistive
20 A
Mechanical Operating Durability
5,000,000
Embedded Surge Suppressor
No
NEMA Enclosure Rating
No Enclosure
Full Load Current - Inductive
12 A
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 600V AC
10 hp
Minimum Operating Temperature
-13 Degrees F
Mounting Support
Rail; Plate
Control Circuit Type
AC 50/60 Hz
Associated Fuse Rating
25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Overvoltage Category
CAT III
Signalling Circuit Frequency
Less Than 400 Hz
Connections - Terminals
screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end
Flame Retardance
V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Minimum Switching Current
5 mA for signalling circuit
Control Circuit Voltage
230 to 240 V AC 50/60 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage
17 V for signalling circuit
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Electrical Durability
0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
Operating Speed
3600 cycles per hr
Rated Operational Current
12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Motor Power KW
3 kW 220 to 230 V AC 50/60 Hz; 5.5 kW 380 to 415 V AC 50/60 Hz; 5.5 kW 440 V AC 50/60 Hz; 4 kW 690 V AC 50/60 Hz
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Tightening Torque
0.8 to 1.3 Nm
Rated Insulation Volts
600/690V
IP Degree Of Protection
IP20 VDE 0106
Rated Insulation Voltage
Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No 14
Features
Preassembled with Reversing Power Busbar
Device Application
Control
Switching Current
5 mA (Signalling Circuit)
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Hold-In Power Consumption in VA
4.5 VA (at 68°F (20°C))
Rated Making Capacity
144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Electrical Connection
Screw Clamp Terminals
Inrush Power in VA
30 VA (at 68°F (20°C))
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Maximum Operating Rate
3600 cyc/h
Rated Operational Voltage
Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
IRMS Rated Making Capacity
144 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated Short-Time Withstand Current
115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Thermal Amperage
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Max. Operating Watts
4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Impulse Withstand Voltage
8 kV
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Protective Treatment
TC IEC 60068; TC DIN 50016
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Power Pole Contact Composition
3 NO
Ambient Air Temperature For Operation
-13 to 122°F (-25 to 50°C)
Auxiliary Contacts Type
Instantaneous 1 NC
Operating Altitude
6561.68 ft (2000 m) without derating
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Control Circuit Voltage Limits
Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Product Or Component Type
Reversing contactor
Utilisation Category
AC-3; AC-3e; AC-4; AC-1
Ambient Air Temperature For Storage
-58 to 176°F (-50 to 80°C)
Rated Breaking Capacity
110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Product Certifications
CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Rated Short Time Withstand Current
115 A 122°F (50°C) - 1 s for power circuit; 105 A 122°F (50°C) - 5 s for power circuit; 100 A 122°F (50°C) - 10 s for power circuit; 75 A 122°F (50°C) - 30 s for power circuit; 55 A 122°F (50°C) - 1 min for power circuit; 50 A 122°F (50°C) - 3 min for power circuit; 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Interlocking Type
Mechanical
Mechanical Durability
5 Mcycles
Application
Motor Control, Resistive Load
Non Overlap Distance
0.02 in (0.5 mm)
Contactor Application
Motor control; Resistive load
Switching Voltage
17 V (Signalling Circuit)
Insulation Resistance
Greater than 10 MOhm for signalling circuit