Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
1-1/2
Rated Insulation Volts
600/690V
Max. Operating Watts
1.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 2.2 kW (at 380 to 415V AC 50/60 Hz AC-3), 3 kW (at 440V AC 50/60 Hz AC-3), 3 kW (at 480V AC 50/60 Hz AC-3), 3 kW (at 500 to 600V AC 50/60 Hz AC-3), 3 kW (at 660 to 690V AC 50/60 Hz AC-3), 1.5 kW (at 400V AC 50/60 Hz AC-4), 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 2.2 kW(at 380 to 415V AC 50/60 Hz AC-3e), 3 kW (at 440V AC 50/60 Hz AC-3e), 3 kW (at 480V AC 50/60 Hz AC-3e), 3 kW (at 500 to 600V AC 50/60 Hz AC-3e), 3 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Overvoltage Category
CAT III
Control Circuit Voltage Limits
Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Signalling Circuit Frequency
Less Than 400 Hz
Environmental Attributes
Mercury Free, Toxic Heavy Metal Free
Electrical Durability
1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
Application
Motor Control
Switching Current
5 mA (Signalling Circuit)
Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit)
Switching Voltage
17 V (Signalling Circuit)
Operating Speed
3600 cycles per hr
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Mechanical Durability
10 Mcycles
Tightening Torque
0.8 to 1.3 Nm
Rated Breaking Capacity
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Impulse Withstand Voltage
8 kV
Rated Making Capacity
110 A
NEMA Enclosure Rating
No Enclosure
Horsepower @ Three Phase - 480V AC
3 hp
Horsepower @ Single Phase - 240V AC
1 1/2 hp
Resistance Properties
Insulation Resistant
Horsepower @ Single Phase - 120V AC
1/2 hp
Embedded Surge Suppressor
No
Electrical Operating Durability
1,300,000
Maximum Voltage Rating
690V AC
Full Load Current - Inductive
6:00 AM
Horsepower @ Three Phase - 240V AC
1 1/2 hp
Horsepower @ Three Phase - 600V AC
3 hp
Mounting Style
DIN Rail, Plate
Horsepower @ Three Phase - 208V AC
1 1/2 hp
Full Load Current - Resistive
15 A
Mechanical Operating Durability
10,000,000
Includes Auxiliary Contacts
Yes
Number of Normally Open Main Contacts
3
Non Overlap Distance
0.02 in (0.5 mm)
Inrush Power in VA
30 VA (at 68°F (20°C))
Auxiliary Contacts Type
Instantaneous 1 NO
Device Application
Control
Operating Altitude
6561.68 ft (2000 m) without derating
Conventional Free Air Thermal Current
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Rated Operational Voltage
Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz; Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate
3600 cyc/h
Control Circuit Type
AC 50/60 Hz
Utilisation Category
AC-3; AC-3e; AC-4
Control Circuit Voltage
200 to 208 V AC 50/60 Hz
Protective Treatment
TC IEC 60068; TC DIN 50016
Rated Operational Current
6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Ambient Air Temperature For Storage
-58 to 176°F (-50 to 80°C)
Mechanical Robustness
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Pole Contact Composition
3 NO