- Item
- Safety Interlock Switch
- Series
- XCSE
- Electrical Connection
- terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
- Head Material
- zamak
- Body Material
- zamak
- Standards
- CSA C22.2 No 14 || UL 508 || EN/ISO 12100 || EN 1088/ISO 14119 || EN/IEC 60204-1 || EN/IEC 60947-5-1
- Material
- metal
- Mechanical Durability
- 1000000 cycles
- Head Type
- key operated turret head
- Shock Resistance
- 10 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 5 gn 10-500 Hz)IEC 60068-2-6
- Component Name
- XCSE
- Number Of Poles
- 3
- Signalling Circuit Voltage
- 24/48 V 20...52 V)
- Ip Degree Of Protection
- IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
- Ambient Air Temperature For Storage
- -40-70°C
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-5-1
- Maximum Actuation Speed
- 0.5 m/s
- Electrical Shock Protection Class
- class I EN/IEC 61140
- Solenoid Contacts Type And Composition
- 1 NC + 1 NO slow-break, simultaneous)
- Positive Opening
- with NC contact
- [Us] Rated Supply Voltage
- 24 V - 20...10 %
- Product Certifications
- UL || CSA
- Ambient Air Temperature For Operation
- -25-40°C
- Contact Operation
- slow-break, break before make
- Power Consumption In Va
- 10 VA inrush || 10 VA sealed
- Design
- rectangular
- Load Factor
- 1
- Supply Voltage Type
- AC/DC
- Signalling Circuit Type
- AC/DC
- [Ui] Rated Insulation Voltage
- 50 VEN/IEC 60947-1 signalling circuit
- Actuator Forcible Withdrawal Rtc
- 2000 N
- [Ie] Rated Operational Current
- 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
- Cable Entry
- 2 entries tapped Pg 13.5
- Electromagnet Interlocking
- locking on energisation and unlocking on de-energisation of solenoid
- Protection Type
- overvoltage protection signalling circuit
- [Ithe] Conventional Enclosed Thermal Current
- 6A
- Short-Circuit Protection
- 10 A cartridge fuse gG (gl)
- Minimum Actuator Force For Extraction
- 20 N
- Supply Frequency
- 50/60 Hz
- Product Or Component Type
- safety switch
- Local Signalling
- for guard open/guard closed and locked 2 LEDs (green or orange)
- Protective Treatment
- TC
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
- Minimum Actuation Speed
- 0.01 m/s
- Maximum Operating Rate
- 10 cyc/mn for maximum durability
- Contacts Type And Composition
- 2 NC + 1 NO
- Signalling Circuit Consumption
- 7 mA
- Actuator Material
- Metal